1   Overview

1.1   Description

The alarm is issued when the software and configuration backup in an Ericsson Centralized User Database (CUDB) node has failed.

The alarm attributes are listed and explained in Table 1.

Table 1    Alarm Attributes

Attribute Name

Attribute Value

Auto Cease

Yes

Module

OPERATING-SYSTEM

Error Code

1

Timestamp First

Date and time when the alarm was raised for the first time.

Repeated Counter

Number which indicates how many times the alarm was raised.

Timestamp Last

Date and time of the most recent alarm raise.

Resource ID

.1.3.6.1.4.1.193.169.5.1.<IP>

Alarm Model Description

Server configuration backup fault, Operating System.

Alarm Active Description

Operating System: server configuration backup failed @<IP>

ITU Alarm Event Type

processingErrorAlarm (4)

ITU Alarm Probable Cause

applicationSubsystemFailure (158)

ITU Alarm Perceived Severity

(5) - Minor

Originating source IP

Node IP where the alarm was raised.

Sequence Number

Number which indicates the order in which the alarms are raised.

In Table 1, the indicated variables are as follows:

For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].

The possible causes are as follows:

1.2   Prerequisites

1.2.1   Documents

Refer to CUDB System Administrator Guide, Reference [2] for further information.

1.2.2   Tools

Not applicable.

1.2.3   Conditions

Not applicable.

2   Procedure

Perform the following steps:

  1. Check the disk storage space in /home in the controllers. If there is not enough space, remove previous backups.
  2. Run the backup again. For further information, refer to CUDB Backup and Restore Procedures, Reference [3]. If itworks correctly the alarm will be cleared.
  3. If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.

Glossary

For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [4].


Reference List

CUDB Documents
[1] CUDB Node Fault Management Configuration Guide.
[2] CUDB System Administrator Guide.
[3] CUDB Backup and Restore Procedures.
[4] CUDB Glossary of Terms and Acronyms.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    Operating System, Server Configuration Backup Fault         Ericsson Centralized User Database