1 Introduction
This document describes every system-level, node-level and auxiliary administration and configuration procedure available for the Ericsson Centralized User Database (CUDB).
1.1 Document Purpose and Scope
The purpose of this document is to provide detailed information about the administration and configuration procedures available for CUDB.
Therefore, the guide describes the following:
- The resources and settings available to access and configuration in a CUDB node.
- The interfaces and tools through which the above resources and settings can be accessed and configured.
- The steps of performing management procedures.
The final execution permissions on a procedure are determined by taking into consideration the more restrictive permissions applied to every command executed during the procedure. Refer to CUDB Node Commands and Parameters, Reference [1] for user type permissions.
1.2 Revision Information
| Rev. A | This document is based on 2/1543-HDA 104
03/9 with the following changes:
| |
1.3 Typographic Conventions
Typographic conventions can be found in the following document:
2 Overview
CUDB provides several interfaces and procedures for configuring CUDB nodes. All CUDB nodes in a CUDB system are managed and configured in the same way.
The available interfaces and configuration procedures are described in the sections below.
3 Interfaces and Tools
This section provides a description of the interfaces and tools used for CUDB system administration.
3.1 Interfaces
This section describes every Operation and Maintenance (OAM) interface used to access and manage CUDB. An overall view of these interfaces is shown in Figure 1. More information on each interface is available in the following chapters.
3.1.1 SNMP
The Simple Network Management Protocol (SNMP) v3 is a standard protocol used to interchange administrative information between network elements using the User Datagram Protocol (UDP). Fault reporting in CUDB happens through trap messages sent through SNMP: the trap messages send alarm information to the Network Management System (NMS).
3.1.2 SSH
Secure Shell (SSH) is a network protocol allowing data exchange through a secure channel between two network devices.
SSH is used in CUDB to provide access to the Command Line Interface (CLI).
3.1.3 SFTP
The Secure File Transfer Protocol (SFTP) is built on top of SSH, and is used to remotely and securely access files stored in a CUDB node.
3.1.4 NETCONF
The Network Configuration Protocol (NETCONF) is built on top of SSH, and is a machine-to-machine interface providing means to install, modify, and delete the configuration of the network devices. The CUDB NETCONF interface is provided by Common Operation and Maintenance (COM) component and can be used for configuration purposes instead of the CUDB Configuration CLI (see Section 3.2.2).
The CUDB NETCONF interface provided by COM only supports some of the capabilities defined in the standards.
CUDB NETCONF clients must be configured to use a commit at <close-session> commit behavior. Refer to COM Management Guide, Reference [23] and COM NETCONF Interface Base, Reference [24] for further details about NETCONF.
3.1.5 SCP
The Secure Copy Protocol (SCP) has the same purpose and use as of SFTP but implements a more efficient transfer algorithm.
3.2 Tools
This section describes the tools used to access and configure CUDB.
3.2.1 CUDB CLI
CUDB provides a CLI interface to execute both Linux Distribution Extension (LDE) and specific CUDB commands (refer to LDE Management Guide, Reference [25] and CUDB Node Commands and Parameters, Reference [1]). Access to the CLI interface of the CUDB nodes is offered through SSH using port 22.
To access this CLI from the administration node, use the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
Connection to this CLI requires authentication. Refer to CUDB Users and Passwords, Reference [2] CUDB Users and Passwords for user credentials that can be used to access the CUDB CLI.
3.2.1.1 Finding the Active System Controller
Several troubleshooting resources (such as the cudbGetLogs and cudbAnalyser scripts, or the CoreMW console) can be executed only on the active System Controller (SC). If needed, use the following command to determine which is the active SC:
# cudbHaState | grep COM | grep ACTIVE
The expected output must be similar to the below example:
COM is assigned as ACTIVE in controller SC-1.
3.2.2 CUDB Configuration CLI
CUDB provides a CLI interface to perform configuration updates. This CLI is based on the COM CLI and can be reached from a regular CUDB CLI session on the active SC. Refer to COM Management Guide, Reference [23] for more information.
To access the configuration CLI from a regular CLI session, follow the steps below:
- Establish a CUDB CLI session towards the CUDB node, use
the following command:
ssh -l cudbadmin <CUDB_Node_OAM_IP_Address>
- Use the command below (the output is also shown) to find
the active SC:
cudbHaState | grep COM | grep ACTIVE
COM is assigned as ACTIVE in controller SC-1
The active SC (SC_2_1 in the example above) must be used for accessing the COM CLI.
For cudbadmin user:
sudo cudbHaState | grep COM | grep ACTIVE
- Access the COM CLI by executing the following command:
sudo /opt/com/bin/cliss
3.2.3 CUDB Platform Interfaces
The following platform elements provide a CLI for configuration purposes:
- evolved Virtual IP (eVIP): Refer to eVIP Management Guide, Reference [26] for information about this CLI.
- Blade Server Platform 8100 (BSP 8100).
3.2.4 LDAP Schema Management Tools
CUDB provides tools for managing the Lightweight Directory Access Protocol (LDAP) schema, which can be executed on any Linux machine with Java, or also on the SCs of a CUDB node through SSH. The available tools are as follows:
- Schema Management Graphical User Interface (GUI): see Section 15.3 for more information.
- Schema Update Tool: see Section 15.4 for more information.
3.2.5 UDC Cockpit
UDC Cockpit tool, formerly known as CUDB Observability Tool is a GUI that is used to monitor the system at real-time, and to analyze historical data. The GUI monitors LDAP counters, mastership, and alarms. The Cockpit GUI is accessed through a web interface, and uses SSH and SNMP interfaces to communicate with the CUDB system.
4 Configuration Data Management
Most of the CUDB configuration data can be managed through the configuration model. Refer to CUDB Node Configuration Data Model Description, Reference [3] for more information.
Configuration data management through the configuration model is possible through the CUDB Configuration CLI and NETCONF interface. See Section 3.2.2 for more information on how to access the CUDB Configuration CLI and Section 3.1.4 for more information on the NETCONF interface.
5 Fault Management
Fault management in CUDB provides a set of services that perform the following roles:
- Notify the system administrator if a problem is detected that requires human intervention.
- Notify the system administrator if particular events occur.
For more information about fault management, refer to CUDB Node Fault Management Configuration Guide, Reference [4].
6 Performance Management
Performance management in CUDB provides two types of statistics:
- CUDB performance indicators, which contain information about CUDB behavior. These counters provide performance information for each CUDB node. Refer to CUDB Counters List, Reference [5] for further information.
- Application statistics, which provide information related to the application data stored in the CUDB system. The statistics are collected and provided on system level. Refer to CUDB Performance Guide, Reference [6] for further information.
7 CPU Load Monitoring
CUDB can monitor the CPU load on all blades or Virtual Machines (VMs) of a CUDB node, and can present the monitoring results in a tabular format. Get information about CPU load monitoring with the cudbMpstat command as follows:
- Establish a new administrative CUDB CLI session towards
the target CUDB node with the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Execute cudbMpstat.
- Exit the script by pressing Ctrl+C.
Refer to CUDB Node Commands and Parameters, Reference [1] for further information.
8 Logging Management
Logging management in CUDB is based on the reported log events.
For further information about logging events in CUDB, refer to CUDB Node Logging Events, Reference [7]. Information on configuring the Centralized Security Event Logging function is also available in that document.
9 CUDB Log Collection
The CUDB system can collect the log files of a specific CUDB node or all the CUDB nodes with the cudbCollectInfo command.
This command collects the log files, and compresses them into tar file format.
For more information about this command, refer to CUDB Node Commands and Parameters, Reference [1].
10 Security Management
CUDB security management provides a set of features to ensure secure authentication and confidentiality for all administrative tasks and traffic scenarios.
Refer to CUDB Security and Privacy Management, Reference [8] for information about security management in CUDB.
11 Backup and Restore Procedures
CUDB offers three types of backup operations:
- Data backup: This operation creates data backups of the information stored in the database.
- Software and configuration backup: This operation creates data backups of the following information:
- Configuration backup of specific infrastructure element(s).
Refer to CUDB Backup and Restore Procedures, Reference [9] and CUDB Node Preventive Maintenance, Reference [10] for information on how to perform backup and restore operations in CUDB.
12 Replication
Replication is automatically handled by CUDB and requires no administrative actions other than handling raised alarms. In case of replication issues, follow the procedures described in the Operating Instructions (OPIs) for replication alarms (refer to CUDB Node Fault Management Configuration Guide, Reference [4] for further information).
13 Reconciliation
Reconciliation is automatically handled by CUDB and requires no administrative actions other than handling raised alarms. In case of reconciliation issues, follow the procedures described in the OPIs for reconciliation alarms (refer to CUDB Node Fault Management Configuration Guide, Reference [4] for further information).
- Note:
- Handling reconciliation issues for the Subscription Reallocation procedure is an exception: in special cases, reconciliation must be requested manually. See Section 18.14 for more information on Subscription Reallocation, and Section 18.15 for more information on manual reconciliation.
Refer to CUDB Data Storage Handling, Reference [11] for more information on reconciliation in CUDB.
14 Networking
The general network infrastructure of the CUDB system is described in CUDB Node Network Description, Reference [12].
15 Data and Schema Management
This section provides information on the administrative tasks related to data and schema management.
15.1 LDAP Data Import and Export
The CUDB system supports the import of LDAP data from LDAP Data Interchange Format (LDIF) files to the database, and also the export of data from the database to LDIF files. Refer to CUDB Import and Export Procedures, Reference [13] for further information.
Import and export can also be performed by LDAP interface. This is commonly used for smaller amounts of data. Refer to Section 15.2 for more information.
15.2 Adding and Searching LDAP Data
To perform addition or search of data, stored in CUDB, using the LDAP interface, standard LDAP clients with access to CUDB traffic network can be used.
The following chapters contain information about Open LDAP tools ldapadd and ldapsearch, which are delivered with CUDB, to perform these operations.
15.2.1 Adding LDAP Data
The following steps give an example of adding LDAP data from LDIF files using ldapadd command, from within the CUDB node:
- Log on to the CUDB node with the PLDB master replica.
- Transfer all LDIF files to the CUDB SC node.
- Note:
- Verify the contents of each LDIF file and replace <root_DN> with the operator-specific root Distinguished Name (DN).
- Import LDIF files using the ldapadd command, for example:
# ldapadd -x -c -H ldap://PL0:389 -D "cn=manager,<root_DN>" -w <manager_password> -S /tmp/error.log -f <path_to_ldif_file>
- Note:
- Replace <root_DN> with the proper root DN.
For more information about LDAP root password, <manager_password> refer to CUDB Users and PasswordsCUDB Users and Passwords, Reference [2].
- Verify that all ldapadd operations
are successful by querying the corresponding error.log file for errors.
- Note:
- Errors are related to common entries, for example, dn: serv=CSPS, ou=mscCommonData, dc=<root_DN> in multiple LDIF files can be ignored.
15.2.2 Searching LDAP Data
Searching LDAP data can be done by using ldapsearch command.
Refer to OpenLDAP, ldapsearch Tool Manual, Reference [27] for more information about the command.
15.3 LDAP Schema Edition
The Schema Tools software provides an easy-to-use graphical interface to create and edit LDAP schemas. For further information, refer to CUDB LDAP Schema Management Graphical User Interface, Reference [14].
- Note:
- The graphical tool requires a Linux machine with Java.
For further information, refer to CUDB LDAP Schema Management Graphical User Interface, Reference [14].
- Note:
- LDAP schema management is restricted to Ericsson personnel. Contact the next level of maintenance support to perform such procedures.
15.4 Schema Update and Index Creation on New Attributes
CUDB provides methods for changing LDAP application schemas by adding new object classes, or adding new attributes to already existing object classes. It is also possible to define indexes on new attributes, no matter if they belong to a new or an already existing object class. CUDB also provides methods to add new application schemas.
- Note:
- LDAP schema update and index creation are restricted to Ericsson personnel. Contact the next level of maintenance support to perform such procedures.
15.4.1 Index Creation
New indexes in a local CUDB node can be created by setting the multivalued attribute ldapAttrIndexes of the CudbLdapAccess class in the configuration model. For more information, refer to the "Class CudbLdapAccess" section of CUDB Node Configuration Data Model Description, Reference [3].
Values of the ldapAttrIndexes attribute must contain all attributes that are to be indexed separated by commas.
LdapAttrIndexes must be defined in the same order on every node.
Refer to Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
16 Startup and Shutdown
This section describes the startup and shutdown operations available in CUDB.
- Note:
- System startup and shutdown must be performed by authorized Ericsson personnel only.
16.1 Initial System Startup
- Note:
- Initial system startup must be performed by authorized Ericsson personnel only.
16.2 Node Startup after Graceful Shutdown
In general, starting a gracefully shut down CUDB node requires no special procedures other than powering it on, and handling the alarms that may be raised (and remain raised) after the node is back online.
16.2.1 Node Startup after a Graceful Shutdown in Case the CUDB System Is Deployed on Native BSP 8100 Hardware
The standard procedure for starting up a node in case the CUDB system is deployed on native BSP 8100 hardware is as follows:
- Login to the BSP 8100 CLI.
- Use the CLI console to check which shelf and slot numbers
are associated with the SCs and payload blades. Execute the following
commands to do so:
>configure
(config)>ManagedElement=1,DmxcFunction=1,Eqm=1,VirtualEquipment=cudb
(config-VirtualEquipment=cudb)>show-table -m Blade -p bladeId, userLabel,administrativeState
The expected output must be similar to the below example:
============================================= | bladeId | userLabel | administrativeState | ============================================= | 0-1 | SC-1 | LOCKED | | 0-11 | PL-6 | LOCKED | | 0-13 | PL-7 | LOCKED | | 0-15 | PL-8 | LOCKED | | 0-17 | PL-9 | LOCKED | | 0-19 | PL-10 | LOCKED | | 0-21 | PL-11 | LOCKED | | 0-23 | PL-12 | LOCKED | | 0-3 | SC-2 | LOCKED | | 0-5 | PL-3 | LOCKED | | 0-7 | PL-4 | LOCKED | | 0-9 | PL-5 | LOCKED | =============================================
- Use the CLI console to power on the SCs and payload blades
fetched in the previous step. After the SCs are unlocked, continue
with the payload blades:
(config)>ManagedElement=1,DmxcFunction=1,Eqm=1,VirtualEquipment=cudb
(config-VirtualEquipment=cudb)>Blade=0-1,administrativeState=UNLOCKED
(config-VirtualEquipment=cudb)>commit -s
(config-VirtualEquipment=cudb)>Blade=0-3,administrativeState=UNLOCKED
(config-VirtualEquipment=cudb)>commit -s
...
(config-VirtualEquipment=cudb)>end
(VirtualEquipment=cudb)>exit
- Exit the CLI console.
- Wait until the SCs are completely powered up.
- After a few minutes, it is possible to log in to the SCs
of the CUDB and verify that all blades in the CUDB are starting up.
To do so, execute the following command:
tipc-config -n
- Note:
- Blades that are up and running are indicated with up (see example below). Therefore, check that all lines
contain up. If not all blades are running
(indicated with down), wait approximately
10 minutes until all of them are initialized. Some blades which are
not running can be missing from the list, so it must be checked that
all blades are on the list and all of them are up.
CUDB_79 SC_2_2# tipc-config -n Neighbors: <1.1.1>: up <1.1.3>: up <1.1.4>: up <1.1.5>: up <1.1.6>: up <1.1.7>: down <1.1.8>: up <1.1.9>: up <1.1.10>: up <1.1.11>: up <1.1.12>: up <1.1.13>: up <1.1.14>: up
Contact the next level of maintenance support if one or more blades fail to initialize in 10 minutes.
- Start the database cluster processes with the following
command:
sudo cudbManageStore -a -o start
- Note:
- If the node has more than one subrack, the subrack with SCs and payload blades must be powered first.
16.2.2 Node Startup after Graceful Shutdown in Case the CUDB System Is Deployed on a Cloud Infrastructure
In case of using Cloud Execution Environment (CEE), starting a gracefully shut down CUDB node deployed on a cloud infrastructure can be done through the Atlas GUI or the OpenStack command-line clients. These procedures are described in Section 16.2.2.1 and Section 16.2.2.2, respectively. For more information about the Atlas GUI, refer to the "Atlas Dashboard End User Guide" document and for more information about the OpenStack command-line tools, refer to the "OpenStack End User Guide" document in the CEE CPI.
In case of using a different cloud solution, refer to the solution-specific documentation for more information.
16.2.2.1 Node Startup after Graceful Shutdown Using the Atlas GUI
To start a gracefully shut down CUDB node through the Atlas GUI, perform the following steps:
- Log in to the Atlas Dashboard.
- Select the appropriate project in the Current Project field and select Project in the View field.
- Click the Instances category.
- Mark both SCs of the CUDB and choose the Start Instances action located in the top bar, under the More Actions drop-down menu.
- Verify that the status of both SCs is Active and the power state is Running.
- After a few minutes, verify that both SCs are up and running.
To do so, log in to the SCs and execute the following commands:
- tipc-config -n
- Note:
- VMs that are up and running are indicated with up (see example below). If one of the SCs is not running (indicated with down), wait a few minutes until it is up. VMs which are not running can be missing from the list, so check that both VMs are on the list and both of them are up.
CUDB_79 SC_2_1# tipc-config -n
Neighbors: <1.1.2>: up
- cudbHaState
- Note:
- If both SCs are fully initialized, only payload VMs will be listed having problems in the output of the command under the "SU states" section. If the "SU states" section lists one of the SCs, it means that the mentioned VM is not fully initialized. If this happens, wait a few minutes, then execute the command again and see if the output has changed and that the SC is not listed anymore.
- tipc-config -n
- Mark all payload VMs of the CUDB and choose the Start Instances action located in the top bar, under the More Actions drop-down menu.
- Verify that the status of all payload VMs is Active and the power state is Running.
- After a few minutes, verify that all VMs are up and running.
To do so, log in to the SCs and execute the following commands:
- tipc-config -n
- Note:
- VMs that are up and running are indicated with up (see example below). Therefore, check that all lines
contain up. If not all VMs are running
(indicated with down), wait approximately
15 minutes until all of them are initialized. VMs which are not running
can be missing from the list, so check that all VMs are on the list
and all of them are up.
CUDB_79 SC_2_2# tipc-config -n
Neighbors: <1.1.1>: up <1.1.3>: up <1.1.4>: up <1.1.5>: up <1.1.6>: up <1.1.7>: down <1.1.8>: up <1.1.9>: up <1.1.10>: up <1.1.11>: up <1.1.12>: up <1.1.13>: up <1.1.14>: up
- cudbHaState
- Note:
- If all VMs are fully initialized, then the message " Status OK" will be listed in the
output of the command under the "SU states" section.
If some of the VMs are listed in this section, it means the mentioned
VM is not fully initialized. In case this happens, wait a few minutes,
then execute the command again and see if the status is changed and
the VM is not listed anymore.
Contact the next level of maintenance support if one or more VMs fail to initialize in 15 minutes.
- tipc-config -n
- Start the database cluster processes with the following
command:
sudo cudbManageStore -a -o start
16.2.2.2 Node Startup after Graceful Shutdown Using OpenStack Command-Line Tools
To start a gracefully shut down CUDB node through the OpenStack command-line, execute the following commands from the Cloud Infrastructure Controller (CIC):
- Execute the following command to start the SCs of the
CUDB:
nova start <SC_id>
- Note:
- Execute the command for both SCs.
- Verify that the status of both SCs is Active and the power state is "1" (Running) with the following
command:
nova show <SC_id>
- Note:
- Execute the command for both SCs.
- After a few minutes, verify that both SCs are up. To do
so, log in to the SCs and execute the following commands:
- tipc-config -n
- Note:
- VMs that are up and running are indicated with up (see example below). If one of the SCs is not running (indicated with down), wait a few minutes until it is up. VMs which are not running can be missing from the list, so check that both VMs are on the list.
CUDB_79 SC_2_1# tipc-config -n
Neighbors: <1.1.2>: up
- cudbHaState
- Note:
- If both SCs are fully initialized, only payload VMs will be listed having problems in the output of the command under the "SU states" section. If the "SU states" section lists one of the SCs, it means that the mentioned VM is not fully initialized. If this happens, wait a few minutes, then execute the command again and see if the output has changed and that the SC is not listed anymore.
- tipc-config -n
- Execute the following command to start payload VMs:
nova start <payload_vm_id>
- Note:
- Execute the command for all payload VMs.
- Verify that the status of payload VMs is Active and the power state is "1" (Running)
with the following command:
nova show <payload_vm_id>
- Note:
- Execute the command for all payload VMs.
- After a few minutes, verify that all VMs are up and running.
To do so, log in to the SCs and execute the following commands:
- tipc-config -n
- Note:
- VMs that are up and running are indicated with up (see example below). Therefore, check that all lines
contain up. If not all VMs are running
(indicated with down), wait approximately
15 minutes until all of them are initialized. VMs which are not running
can be missing from the list, so check that all VMs are on the list
and all of them are up.
CUDB_79 SC_2_2# tipc-config -n
Neighbors: <1.1.1>: up <1.1.3>: up <1.1.4>: up <1.1.5>: up <1.1.6>: up <1.1.7>: down <1.1.8>: up <1.1.9>: up <1.1.10>: up <1.1.11>: up <1.1.12>: up <1.1.13>: up <1.1.14>: up
- cudbHaState
- Note:
- If all VMs are fully initialized, then the message " Status OK" will be listed in the
output of the command under the "SU states" section.
If some of the VMs are listed in this section that means the mentioned
VM is not fully initialized. In case this happens, wait a few minutes,
then execute the command again and see if the status is changed and
the VM is not listed anymore.
Contact the next level of maintenance support if one or more VMs fail to initialize in 15 minutes.
- tipc-config -n
- Start the database cluster processes with the following
command:
sudo cudbManageStore -a -o start
16.3 Node Startup after a Non-Graceful Shutdown
In general, starting a CUDB node after shutting it down requires no special procedures other than powering it on, and handling the alarms that may be raised (and remain raised) after the node is back online. This also applies if the node is restarted after a power failure.
16.3.1 Node Startup after a Non-Graceful Shutdown in Case the CUDB System Is Deployed on Native BSP 8100 Hardware
Compared to a startup after a graceful shutdown, two additional steps must be performed if CUDB nodes deployed on native BSP 8100 hardware are started up after a non-graceful shutdown: due to BSP 8100 characteristics, the blades must be locked before startup, then unlocked when the node is running again.
Refer to the "BSP Equipment Management" document in the BSP 8100 CPI for information on locking blades. See Section 16.2.1 for more information on the startup after a graceful shutdown procedure.
- Note:
- If the node has more than one subrack, the subrack with SCs and payload blades must be powered first.
16.3.2 Node Startup after a Non-Graceful Shutdown in Case the CUDB System Is Deployed on a Cloud Infrastructure
In case the CUDB system is deployed on a cloud infrastructure, follow the instructions in Section 16.2.2 to start up a node.
16.4 Full CUDB System Startup
In certain cases (such as large-scale power outages) it can happen that the entire CUDB system must be started up.
- Note:
- Full CUDB system startups must be performed by Ericsson personnel only. Contact the next level of maintenance support to perform this procedure.
16.5 Node Graceful Shutdown
Node graceful shutdown allows to manually turn off a CUDB node.
- Note:
- Before performing a graceful shutdown, verify that the CUDB node to turn off does not have any Data Store Unit Group (DSG) or PLDB masters (see Section 18.6 for more information). If the node contains a DSG or PLDB master, the mastership must be manually moved to another CUDB node (see Section 18.19 for more information).
16.5.1 Node Graceful Shutdown in Case the CUDB System Is Deployed on Native BSP 8100 Hardware
- Note:
- Depending on the number of sites and nodes in the system, shutting down a CUDB node deployed on native BSP 8100 hardware can result in a symmetrical split situation. For example, if a CUDB node is shut down on a 2-node, 2-site deployment, the remaining node finds itself in a symmetrical split situation.
To perform a graceful shutdown, complete the following steps:
- Establish a CUDB configuration CLI session towards the
target CUDB node with the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Perform a software and configuration backup as described in CUDB Backup and Restore Procedures, Reference [9].
- Stop database cluster processes with the following command:
sudo cudbManageStore -a -o stop
- Exit the CUDB configuration CLI session.
- Establish a root CUDB
CLI session towards the target CUDB node with the following command:
ssh root@<CUDB_Node_OAM_VIP_Address>
- Stop the AMF cluster services in the connected SC with
the following command:
service opensafd stop
After the AMF cluster services in the SC are stopped, connect to the other SC (indicated as SC_2_<x> below, where <x> is the number of the other SC), and stop the AMF cluster services as follows:
ssh SC_2_<x>
service opensafd stopExit the connection to the SC established in this step.
- Exit the root CUDB CLI session to the SC established in Step 5.
- Login to the BSP 8100 CLI.
- Use the CLI console to check which shelf and slot numbers
are associated with the SCs and payload blades. Execute the following
commands to do so:
>configure
(config)>ManagedElement=1,DmxcFunction=1,Eqm=1,VirtualEquipment=cudb
(config-VirtualEquipment=cudb)>show-table -m Blade -p bladeId, userLabel,administrativeState
The expected output must be similar to the below example:
============================================= | bladeId | userLabel | administrativeState | ============================================= | 0-1 | SC-1 | UNLOCKED | | 0-11 | PL-6 | UNLOCKED | | 0-13 | PL-7 | UNLOCKED | | 0-15 | PL-8 | UNLOCKED | | 0-17 | PL-9 | UNLOCKED | | 0-19 | PL-10 | UNLOCKED | | 0-21 | PL-11 | UNLOCKED | | 0-23 | PL-12 | UNLOCKED | | 0-3 | SC-2 | UNLOCKED | | 0-5 | PL-3 | UNLOCKED | | 0-7 | PL-4 | UNLOCKED | | 0-9 | PL-5 | UNLOCKED | =============================================
- Use the CLI console to power off the payload blades and
SCs fetched in the previous step. After the payload blades switched
off, continue with SCs:
(config)>ManagedElement=1,DmxcFunction=1,Eqm=1,VirtualEquipment=cudb
(config-VirtualEquipment=cudb)>Blade=0-23,administrativeState=LOCKED
(config-VirtualEquipment=cudb)>commit -s
(config-VirtualEquipment=cudb)>Blade=0-21,administrativeState=LOCKED
(config-VirtualEquipment=cudb)>commit -s
...
(config-VirtualEquipment=cudb)>Blade=0-3,administrativeState=LOCKED
(config-VirtualEquipment=cudb)>commit -s
(config-VirtualEquipment=cudb)>Blade=0-1,administrativeState=LOCKED
(config-VirtualEquipment=cudb)>commit -s
(config-VirtualEquipment=cudb)>end
(VirtualEquipment=cudb)>exit
- Exit the CLI console.
After performing a graceful node shutdown, performing a health check is recommended on the other nodes of the system. For a detailed description on health check, refer to CUDB Health Check, Reference [15].
16.5.2 Node Graceful Shutdown in Case the CUDB System Is Deployed on a Cloud Infrastructure
In case of using Cloud Execution Environment (CEE), the graceful shutdown of a CUDB node deployed on a cloud infrastructure can be done through the Atlas GUI or the OpenStack command-line tools. These procedures are described in Section 16.5.2.1 and Section 16.5.2.2, respectively. For more information about the Atlas GUI, refer to the "Atlas Dashboard End User Guide" document and for more information about the OpenStack command-line tools, refer to the "OpenStack End User Guide" document in the CEE CPI.
In case of using a different cloud solution, refer to the solution-specific documentation for more information.
After performing a graceful node shutdown, performing a health check is recommended on the other nodes of the system. For a detailed description on health check, refer to CUDB Health Check, Reference [15].
16.5.2.1 Node Graceful Shutdown Using the Atlas GUI
To gracefully shut down a node through the Atlas GUI, perform the following steps:
- Stop the database cluster processes with the following
command:
sudo cudbManageStore -a -o stop
- Log in to the Atlas Dashboard.
- Select the appropriate project in the Current Project field and select Project in the View field.
- Click the Instances category.
- Mark all payload VMs of the CUDB and choose the Shut Off Instances action located in the top bar, under the More Actions drop-down menu.
- Verify that the status of all payload VMs is Shutoff and the power state is Shut Down.
- Mark both SCs of the CUDB and choose the Stop Instances action located in the top bar, under the More Actions drop-down menu.
16.5.2.2 Node Graceful Shutdown Using OpenStack Command-Line Tools
To gracefully shut down a CUDB node through the OpenStack command-line, execute the following commands from CIC:
- Stop the database cluster processes with the following
command:
sudo cudbManageStore -a -o stop
- Execute the following command to stop payload VMs:
nova stop <payload_vm_id>
- Note:
- Execute the command for all payload VMs.
- Execute the following command to stop the SCs of the CUDB:
nova stop <SC_id>
- Note:
- Execute the command for both SCs.
17 Regular Maintenance Procedures
There are maintenance procedures that need to be performed regularly to ensure the correct operation of CUDB.
These procedures also allow system administrators to detect incidental problems. Refer to CUDB Node Preventive Maintenance, Reference [10] for more information on how to detect common problems.
- Note:
- Maintenance of infrastructure equipment is outside the scope of this document.
18 System Level CUDB Procedures
This section describes system-level procedures (such as maintenance operations and scalability tasks) that must be regularly performed in the CUDB system to ensure uninterrupted operation.
- Note:
- Always contact Ericsson support if any problem occurs while performing the following operations.
Do not perform operations (such as adding, removing, or including a CUDB node again in the system) that change the number of available CUDB nodes in the system if the Control, Potential Split Brain Detected alarm is raised.
Refer to CUDB High Availability, Reference [16] for further details on symmetrical split.18.1 Configuring Network Routes Towards Notification Endpoints
After configuring CUDB notifications, the configuration of the network connectivity facilities is needed in the system for communication towards the endpoints. Refer to CUDB Notifications, Reference [18] for more information on how to configure CUDB notifications.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to configure network routes towards notification endpoints.
18.2 Disabling a CUDB Node in a CUDB System
Authenticated access to certain CUDB modules may be needed. Contact Ericsson staff support to obtain the access.
This section describes how to disable a CUDB node in a CUDB system.
- Note:
- When disabling a CUDB node that holds 3 BC servers in a two-node site, a split situation will occur in the CUDB system. In this case, it is recommended to manually move all masters from the CUDB site where the CUDB node will be disabled to another CUDB site before disabling the node. For more information on how to manually manage mastership, see Section 18.19. In case of a two-site deployment, the system will find itself in a symmetrical split situation.
The procedure of disabling a node in a CUDB system is as follows:
- Verify that the node to disable (that is, the target node)
does not have any DSG or PLDB masters (see Section 18.6).
If the node to disable contains DSG or PLDB masters, the mastership must be manually moved to another CUDB node (see Section 18.19).
- Deactivate the CUDB node locally by modifying the CudbLocalNode class in the target node. See Section 19.8 for more information.
- Deactivate the CUDB node remotely by disabling it in the configuration of the rest of CUDB nodes in the system. See Section 20.5 for more information.
- Disable the CUDB Provisioning, CUDB Site, and CUDB Traffic VIP addresses in the local CUDB node. See Section 20.30 for more information on this procedure.
18.3 Enabling a Previously Disabled CUDB Node in a CUDB System
If a CUDB node is disabled in a CUDB system, it can be enabled again if the following conditions are met:
- The configuration of the CUDB node to be enabled again (in short, the "target CUDB node") must contain all information related to the rest of the CUDB nodes present in the system.
- The configuration of the rest of the CUDB nodes in the system must contain all the information on the target CUDB node and its PLDB/DSG units.
Perform the following steps to enable a previously disabled CUDB node in a CUDB system:
- Activate the target node locally. See Section 19.1 for more information.
- Activate the target node in the rest of nodes in the CUDB system. See Section 19.2 for more information.
- Enable the CUDB Provisioning, CUDB SITE, and CUDB Traffic VIP addresses in the local CUDB node. See Section 20.31 for more information on this procedure.
18.4 Creating a New DSG
If more storage capacity is needed in a CUDB system, new DSGs must be added.
- Note:
- A drop in LDAP Front End (FE) node and server counters may be observed until the procedure has been fully completed. This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support if new DSG(s) must be created in the CUDB system.
- Note:
- Perform software and configuration backup and system data backup before creating new DSG(s). Follow the procedures to run backups as specified in CUDB Backup and Restore Procedures, Reference [9].
18.5 Activating a DSG
If a DSG was created recently, or it was deactivated earlier, it must be activated before using it.
If a CUDB node is added to a CUDB system, the situation can look as follows from the perspective of the DSGs:
Both scenarios are covered in the following sections.
18.5.1 Activating a Previously Deactivated DSG in the CUDB System
The activation procedure for a deactivated DSG in a CUDB system is as follows:
- Activate the Data Store (DS) Unit which was the DSG master before deactivation. See Section 20.1 for more information.
- Activate the rest of the DS Units in the DSG by following the procedure in Section 20.1.
18.5.2 Activating a New DSG in the CUDB System
CUDB supports the activation of new DSGs in the system.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support if new DSG(s) must be activated in the CUDB system.
If a new DSG is added to the configuration, always create a new system data backup, because previous backups are not valid any more.
To create a new system data backup, follow the steps described in CUDB Backup and Restore Procedures, Reference [9], Performing System Data Backup section.
18.6 Listing the Master Replicas
Execute the following command to list all master PLDB and DSG replicas:
cudbSystemStatus -R
For further information on this command, refer to CUDB Node Commands and Parameters, Reference [1].
18.7 Setting the Default Geographical Zone Globally
CUDB supports the global configuration of the default geographical zone.
Perform the procedure described in Section 20.15 on every CUDB node to set the default geographical zone. Refer to CUDB Multiple Geographical Areas, Reference [17] for more information on geographical zones.
18.8 Setting Custom Distribution Policy for Distribution Entries Globally
CUDB supports the global configuration of custom distribution policies for Distribution Entries (DEs).
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to configure custom distribution policies for DEs globally.
18.9 Checking the Custom Distribution Policy of DEs Globally
CUDB supports the global check of the custom distribution policies configured for DEs.
Perform the procedure described in Section 20.17 on every CUDB node to check the custom distribution policy of DEs.
18.10 Restoring the Default Distribution Policy of DEs Globally
CUDB supports the global restore of the custom distribution policies configured for DEs.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to restore custom distribution policies for DEs globally.
18.11 Activating and Deactivating Notifications Globally
CUDB supports the global activation and deactivation of notifications.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to activate or deactivate notifications globally.
18.12 Deactivating Specific Notifications Globally
CUDB supports the global deactivation of specific notifications.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to deactivate specific notifications globally.
18.13 Adding Space to a BLOB in the Disk Storage System Globally
CUDB supports the global increase of space for a Binary Large Object (BLOB) in the disk storage system.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to add space to a BLOB in the disk storage system globally.
18.14 Configuring Subscription Reallocation
Subscription Reallocation (also known as "reallocation") makes it possible to move stored data from one DSG to another.
Reallocation can be executed by moving away a specified percentage of DS entries from source DSG or by providing a list of entries to be moved to the specified destination DSG. Refer to CUDB Subscription Reallocation, Reference [19] for more information about reallocation and to CUDB Node Commands and Parameters, Reference [1] for more information about the options of the cudbReallocate command.
- Note:
- It is recommended to perform a backup in the CUDB system
before running reallocation. Refer to CUDB Backup and Restore Procedures, Reference [9] for
more information.
It is also recommended to create reconciliation tasks manually after performing reallocation. Create a reconciliation task for each DSG which is a source during the reallocation. Refer to CUDB Node Commands and Parameters, Reference [1] for more information about the full syntax of the available reconciliation commands.
Always execute defragmentation on the source DSG after any kind of reallocation has been applied. See Section 18.16 for more information.
18.15 Requesting Reconciliation Manually
Perform the following procedure to request a reconciliation task manually:
- Find the master DS replica of the affected DSG. See Section 18.6 for more information.
- Perform the procedure described in Section 19.7 on the CUDB node hosting the master replica to subscribe the DS master replica to reconciliation.
18.16 Running Defragmentation
Defragmentation is aimed to reorganize the way memory is stored in the PLDB or DS units of the target DSG, to reduce the number of memory gaps.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to perform defragmentation.
18.17 Configuring Provisioning Gateway Nodes
CUDB is able to send notifications to the Ericsson Provisioning Gateway (PG) nodes for provisioning to be stopped during procedures such as system data backup or software upgrade.
For more information on stopping provisioning during backup, refer to CUDB Backup and Restore Procedures, Reference [9].
The prerequisite for sending PG notifications is that CUDB nodes are updated with the latest PG configuration information in case there is any change in the PGs connected to the CUDB system. This includes adding or removing PG nodes, or changing the IP address of an existing PG node.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to configure PG nodes.
18.18 CUDB LDAP User Management
If a new CUDB LDAP user or group is added, an existing one is deleted, or the CUDB LDAP user attributes are changed, the LDAP configuration must be updated accordingly. Perform the following procedure to do so:
- Choose a PLDB Master node where the LDAP user data change is added to the configuration model.
- Perform one (or more) of the following procedures, depending
on the type of LDAP change:
- To create a new LDAP user, see Section 20.23.
- To delete an existing LDAP user, see Section 20.27.
- To modify an existing LDAP user, see Section 20.24.
- To create a new LDAP user group, see Section 20.22.
- To delete an existing LDAP user group, see Section 20.28.
- The above changes in LDAP user management are automatically propagated to the rest of the CUDB nodes through replication. If that happens, choose another CUDB node and follow the procedure described in Section 20.26 .
- Repeat Step 3 on every CUDB node apart from the one selected in Step 1.
Refer to CUDB LDAP Interwork Description, Reference [20] for more information on managing LDAP user attributes.
18.19 Changing DSG or PLDB Mastership Manually
This section describes how to move the mastership of a DSG or PLDB to a preferred node as part of a planned master change.
- Note:
- The cudbSystemStatus command is used to locate the master replicas.
To perform the mastership change, log in to the target node (where the master replica is to be hosted) and execute the following command:
cudbDsgMastershipChange
Refer to CUDB Node Commands and Parameters, Reference [1] for more information on the command.
18.20 Updating LDAP Schema Globally
CUDB supports the global update of the LDAP schema.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to update the LDAP schema globally.
18.21 Activating DS Units
The process of activating a DS Unit depends on whether the unit plays a local or remote role in a CUDB node.
- To activate a local DS Unit in a CUDB node, see Section 20.1.
- To activate the same DS Unit in the rest of the CUDB nodes as a remote node, see Section 20.3.
18.22 Deactivating DS Units
The process of deactivating a DS Unit depends on whether the unit plays a local or remote role in a CUDB node.
- To deactivate a local DS Unit in a CUDB node, see Section 20.2.
- To deactivate the same DS Unit in the rest of the CUDB nodes where it acts as remote node, see Section 20.4.
18.23 Configuring Automatic Mastership Change
CUDB is able to automatically change the master to the highest priority DSG or PLDB replica, when the master replica is in a different DSG or PLDB replica. For more information, refer to CUDB High Availability, Reference [16].
To configure Automatic Mastership Change (AMC), modify the CudbAutomaticMasterChange class (refer to the "Class CudbAutomaticMasterChange" section of CUDB Node Configuration Data Model Description, Reference [3]) in the configuration model as follows:
- To enable or disable AMC, set the enabled attribute to the corresponding value of true or false.
- To change the maximum replication delay, modify the maxReplicationTimeDelay attribute. The value of the attribute is the number of milliseconds. Refer to the "Class CudbAutomaticMasterChange" section of CUDB Node Configuration Data Model Description, Reference [3] for the default value.
- To change the time window, in which AMC is running, modify the attributes timeWindowStart and timeWindowEnd, as described in the "Class CudbAutomaticMasterChange" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
18.24 LDAP Data Views Management
The LDAP Data Views function supports accessing stored data through customizable views. The function is based on assigning views to LDAP users. If the LDAP user sending a request has an LDAP view assigned by configuration, then that user can access the data through that view.
Refer to CUDB LDAP Data Views Management, Reference [21] for detailed information on all the steps required to create, configure, and delete an LDAP view.
- Note:
- The LDAP Data Views function can only be used if the Application Facilitator Value Package is available.
18.25 OAM Centralized Authentication System Support
CUDB allows to define and manage new OAM users and groups in remote LDAP servers only, in a centralized way, instead of having to create them locally on all CUDB nodes.
Refer to CUDB Security and Privacy Management, Reference [8] for more information on how to create and authenticate remote OAM users.
19 Node Level CUDB Procedures
This section describes node-level procedures that may need to be performed in the CUDB system.
- Note:
- Always contact Ericsson support if any problem occurs while performing the following operations.
19.1 Activating a Local CUDB Node
When a CUDB node is installed, it must be activated before using it.
To activate a CUDB node locally, set the value of the enabled attribute of the corresponding instance of the CudbLocalNode class to true. For more information, refer to the "Class CudbLocalNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
19.2 Activating a Remote CUDB Node
Before activating a previously deactivated CUDB node locally, it must be activated remotely in the rest of the CUDB nodes of the system.
To activate a CUDB node remotely, set the value of the enabled attribute of the corresponding instance of the CudbRemoteNode class to true. For more information, refer to the "Class CudbRemoteNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
19.3 Modifying a CUDB Node Name
The name of a CUDB node can be modified after installation.
To modify the name of a CUDB node, change the value of the networkElementName attribute of the corresponding instance of the CudbLocalNode class. For more information, refer to the "Class CudbLocalNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
19.4 Modifying the DSG or PLDB Cluster State
The procedure to modify the state of a DSG or PLDB cluster is the following:
- Establish a CUDB CLI session towards the target CUDB node
with the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Execute the cudbManageStore command on the target cluster to modify its state to the new state.
In case of a DSG cluster, use the command as follows:
sudo cudbManageStore --ds <dsId> --order <New_state>
In case of a PLDB cluster, use the command as follows:
sudo cudbManageStore --pl --order <New_state>
Refer to CUDB Node Commands and Parameters, Reference [1] for detailed information on cluster states.
- Exit the CUDB CLI session with the following command:
exit
- Note:
- Changing the state of a cluster in a way that renders the
cluster offline (such as changing to maintenance mode, or restoring
an earlier backup) can have serious consequences.
If a DSG cluster containing a master replica goes offline, a new DSG master is selected. However, if the PLDB cluster goes offline, the corresponding CUDB node also goes offline.
19.5 Checking Software Inventory on a CUDB Node
CUDB provides several ways to check what software is installed on a CUDB node. These methods are described in the next sections.
19.5.1 Checking Imported Software on a CUDB Node
CUDB provides a mechanism to check which packages have been imported to a CUDB node. To check the Software Inventory of a CUDB node, perform the following steps:
- Establish a CUDB CLI session towards the target CUDB node
with the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Check the software packages installed in the CUDB node
with the following command:
cmw-repository-list
- Note:
- The above procedure lists packages either as "Used" or "Not used". Packages listed as "Used" are installed packages, while packages listed as "Not used" are packages that have been imported, but not yet installed.
- Exit the CUDB CLI session with the following command:
exit
19.5.2 Checking Installed Software on Each Blade or VM of a CUDB Node
CUDB provides a mechanism to check what packages are installed on each blade or VM of a CUDB node. To check the Software Inventory in a specific blade or VM of a CUDB node, perform the following steps:
- Establish a CUDB CLI session towards the CUDB node with
the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Check the software packages installed in the CUDB node
with the following command:
sudo cmw-rpm-list <CUDB_node_blade_or_vm_host_name>
In the above command, the <CUDB_node_blade_or_vm_host_name> variable is used to indicate the blade or VM host name to be checked. If left empty, all blades or VMs are listed. The host name can be the following:
- Exit the CUDB CLI session with the following command:
exit
19.6 Defragmenting a Database Cluster
The CUDB system supports the defragmentation of individual database clusters.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to defragment CUDB nodes.
19.7 Subscribing a DSG Master Replica to Reconciliation Manually
Perform the following steps to subscribe a DSG master replica to reconciliation manually:
- Establish a new administrative CUDB CLI session towards
the target CUDB node with the following command:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Execute the following command:
sudo cudbReconciliationMgr --add <dsg_id>
In the above command, <dsg_id> is the identifier of the DSG to which the target master DSG replica belongs.
Refer to CUDB Node Commands and Parameters, Reference [1] for further information on this command.
19.8 Deactivating a Local CUDB Node
To deactivate a CUDB node locally, set the value of the enabled attribute of the corresponding instance of the CudbLocalNode class to false. For more information, refer to the "Class CudbLocalNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
19.9 Storage Performance Monitoring Function
The CUDB system can detect storage system failures on SCs and payload blades or VMs by two mechanisms:
- Monitoring I/O heavy processes (the time spent in D state).
- Probing the file system.
CUDB supports the activation, deactivation of the Storage Performance Monitoring function, and the configuration of the function parameters by modifying the /home/cudb/monitoring/blade/config/cudbHwFaultReaction.json configuration file. Storage Performance Monitoring is enabled by default.
- Note:
- This configuration file can be changed by Ericsson personnel only.
20 Auxiliary CUDB Procedures
The procedures described in this section are required to properly maintain a CUDB system, but are not supposed to be executed in a standalone manner. Instead, they are parts of higher-level, more complex procedures, such as those described in Section 18 and Section 19.
20.1 Activating a DS Unit in a Local CUDB Node
Before using a DS Unit in a DSG, it must be activated.
To activate a DS Unit in a local CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbLocalDs class to true. For more information, refer to the "Class CudbLocalDs" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.2 Deactivating a DS Unit in a Local CUDB Node
DS Units in a CUDB node are usually deactivated for maintenance reasons.
To deactivate a DS Unit in a local CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbLocalDs class to false. For more information, refer to the "Class CudbLocalDs" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
Even if a DS Unit is deactivated, it continues to operate. Therefore, it can raise alarms even if being deactivated.
20.3 Activating a DS Unit in a Remote CUDB Node
To activate a DS Unit in a remote CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbRemoteDs class to true. For more information, refer to the "Class CudbRemoteDs" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.4 Deactivating a DS Unit in a Remote CUDB Node
To deactivate a remote DS Unit, set the value of the enabled attribute of the corresponding instance of the CudbRemoteDs class to false. For more information, refer to the "Class CudbRemoteDs" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
Even if a DS Unit is deactivated, it continues to operate. Therefore, it can raise alarms even if being deactivated.
20.5 Deactivating a Remote CUDB Node
After a CUDB node is deactivated locally, it is necessary to deactivate it also in the rest of CUDB nodes.
To deactivate a remote CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbRemoteNode class to false. For more information, refer to the "Class CudbRemoteNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.6 Adding a DSG to a Local CUDB Node
CUDB supports adding new DSGs to a local CUDB node.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to add new DSGs to a local CUDB node.
20.7 Adding a DS Unit to a Local CUDB Node
When a new DSG is created or the geographical redundancy of the system is upgraded, the new DS Units must be added to the CUDB node configuration where the new DS Unit is hosted.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to add a DS Unit to a local CUDB node.
20.8 Adding a Generic Blade or VM to a Local CUDB Node
CUDB supports adding new blades or VMs to local CUDB nodes.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to add new blades or VMs to CUDB nodes.
20.9 Configuring a DS Unit Added to a Local CUDB Node
After new blades or VMs were added to a CUDB node, the DS Unit must be configured.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to configure the new blades or VMs added to the CUDB node.
20.10 Configuring a DS Unit Added to a Remote CUDB Node
When a new DS Unit is added to the CUDB system, it must be configured both on its local node, and also on the rest of the CUDB nodes to recognize it in the entire system.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to configure the new blades or VMs added to the CUDB node.
- cudbRemoteDsId
- dsGroupId
- enabled
For more information on the CudbRemoteDs class, refer to the "Class CudbRemoteDs" section of CUDB Node Configuration Data Model Description, Reference [3].
20.11 Deactivating a Local PLDB Unit
To deactivate a local PLDB unit in a CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbLocalPl class to false. For more information, refer to the "Class CudbLocalPl" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.12 Activating a Local PLDB Unit
To activate a PLDB unit in a CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbLocalPl class to true. For more information, refer to the "Class CudbLocalPl" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.13 Deactivating a Remote PLDB Unit
To deactivate a PLDB unit belonging to another CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbRemotePl class to false. For more information, refer to the "Class CudbRemotePl" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.14 Activating a Remote PLDB Unit
To activate a PLDB unit belonging to another CUDB node, set the value of the enabled attribute of the corresponding instance of the CudbRemotePl class to true. For more information, refer to the "Class CudbRemotePl" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.15 Setting the Default Geographical Zone
To set the default geographical zone in a specific CUDB node, set the value of the defaultZone attribute of the corresponding instance of the CudbSystem class to the new default geographical zone. For more information, refer to the "Class CudbSystem" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
- Note:
- Setting the default zone is only possible if the Deployment Flexibility Value Package is available.
20.16 Setting Custom Distribution Policy for DEs
CUDB supports the configuration of custom distribution policies for DEs in the CUDB nodes.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to set custom distribution policy for DEs.
20.17 Checking The Custom Distribution Policy of DEs
To check whether a specific CUDB node is using the default distribution policy or a custom one, perform the following steps:
- Establish a CUDB CLI session with the following command
towards the CUDB node where the distribution policy is to be checked:
ssh <admin_user>@<CUDB_Node_OAM_VIP_Address>
- Check the status of the distribution policy with the following
command:
sudo cudbManageLibDataDist --status
The output of the command clearly states if a custom distribution policy is being applied.
- Exit the CUDB CLI with the following command:
exit
20.18 Restoring the Distribution Policy of DEs
CUDB supports restoring the default distribution policy of DEs.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to restore the distribution policy of DEs.
20.19 Increasing the Space of a BLOB in the Disk Storage System
CUDB supports increasing the space of a BLOB in the disk storage system.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to increase the space of a BLOB in the disk storage system.
20.20 Enabling or Disabling Notifications for All Applications
CUDB supports enabling or disabling notifications for all applications.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to enable or disable notifications.
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.21 Disabling Notifications towards a Specification Application End Point
CUDB can prevent the sending of notifications to a particular application Front End (FE) even if notifications are globally enabled.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to disable notifications for a specific application.
20.22 Creating a CUDB LDAP User Group in a Local CUDB Node
To create a new CUDB LDAP user in a local CUDB node, add a new instance of the CudbLdapUserGroup class to the configuration model. For more information, refer to the "Class CudbLdapUserGroup" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.23 Adding a New CUDB LDAP User to a Local CUDB Node
To add a new CUDB LDAP user to a local CUDB node, add a new instance of the CudbLdapUser class to the configuration model and set the following mandatory attributes:
- cudbUserPassword
- cudbUserGroup
- readModeInPL
- readModeInDS
Additional optional attributes can also be configured for the LDAP user, each in a new line.
For more information on the CudbLdapUser class, refer to the "Class CudbLdapUser" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
- Note:
- CUDB supports the following value combinations for the readModeInPL and readModeInDS LDAP user attributes:
- readModeInPL=LP (Local Preferred) and readModeInDS=MP (Master Preferred).
- readModeInPL=MA and readModeInDS=MA (both Master Always).
20.24 Configuring Attributes of a CUDB LDAP User
Once a CUDB LDAP user is created, a set of attributes can be modified. These attributes are listed below:
'countersGroup'
'readModeInPL'
'readModeInDS'
'isProvisioningUser'
'isReProvisioningUser'
'userLdapAuth'
'userLdapHash'
'overloadRejectionWeight'
'cudbUserPassword'
Changes for the userLdapAuth, userLdapHash, and cudbUserPassword attributes are described in CUDB Security and Privacy Management, Reference [8].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.25 Configuring a PG Node in a Local CUDB Node for Backup Notification
PG nodes are configured in CUDB nodes as the destination for backup notifications.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to add new CUDB LDAP users to CUDB nodes.
Nodes are separated with "," and addresses for each node are separated with ";".
20.26 Updating CUDB LDAP User Information in a CUDB Node
To update CUDB LDAP user information in a remote CUDB node, perform the following steps:
- Execute the administrative operation updateUserInfo. Refer to the "updateUserInfo" section of CUDB Node Configuration Data Model Description, Reference [3] for more information on the updateUserInfo administrative operation.
- After executing updateUserInfo, check the CudbLdapUser class in the
configuration model to see whether the change was applied correctly.
For more information on how to perform this check, refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3].
For more information on the CudbLdapUser class, refer to the "Class CudbLdapUser" section of CUDB Node Configuration Data Model Description, Reference [3].
- If the changes were not applied, then the CUDB node has not been informed of the update yet. In this case, execute updateUserInfo again.
20.27 Deleting a CUDB LDAP User in a Local CUDB Node
To delete a CUDB LDAP user from a local CUDB node, delete the appropriate instance of the CudbLdapUser class from the configuration model. For more information, refer to the "Class CudbLdapUser" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.28 Deleting a CUDB LDAP User Group in a Local CUDB Node
To delete a CUDB LDAP user in a local CUDB node, delete the appropriate instance of the CudbLdapUserGroup class from the configuration model. For more information, refer to the "Class CudbLdapUserGroup" section of CUDB Node Configuration Data Model Description, Reference [3].
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.29 Removing Huge Files
The removal of huge files with the rm Linux command results in instability in blades or VMs. Also, if executed on the SC, input/output resources cannot be accessed by the processes running on it.
Therefore, to avoid stability and performance issues, it is strongly recommended to use the following command instead of rm to remove huge files:
ionice -c 3 ls -1 <files to remove> | sed 's/\(.*\)/sleep 1 \&\& ionice -c 3 rm -fv \1/g' | bash
20.30 Disabling Provisioning, Traffic, and Site VIP Addresses
To disable Provisioning, Traffic, and Site VIP addresses, perform the following steps:
- Set the value of the adminState attribute of the CudbTrafficControlManager class to UNLOCKED.
- Note:
- Make sure that this step is executed before moving on to the next steps.
- Create a new blocking rule for the Provisioning VIP address:
- Add a new instance of the CudbTrafficBlockingRule class under the CudbTrafficControlManager class.
- Set the value of the blockedVIP attribute to the Provisioning VIP address that can be obtained from the network plan.
- Create a new blocking rule for the Traffic VIP address:
- Add a new instance of the CudbTrafficBlockingRule class under the CudbTrafficControlManager class.
- Set the value of the blockedVIP attribute to the Traffic VIP address that can be obtained from the trafficVIP attribute of the CudbLocalNode class.
- Create a new blocking rule for the Site VIP address:
- Add a new instance of the CudbTrafficBlockingRule class under the CudbTrafficControlManager class.
- Set the value of the blockedVIP attribute to the Site VIP address that can be obtained from the cudbVIP attribute of the CudbLocalNode class.
- Check the trafficControlManagerState attribute of the CudbTrafficControlManager class.
If trafficControlManagerState is DISABLED, then a problem occurred during the activation of the configuration change in the node, and the node behavior cannot be guaranteed to be consistent with the configuration.
- Note:
- The cudbTrafficBlockingRuleId attribute must be unique for each newly created blocking rule.
For more information on the CudbTrafficBlockingRule class, refer to the "Class CudbTrafficBlockingRule" section of CUDB Node Configuration Data Model Description, Reference [3].
For more information on the CudbTrafficControlManager class, refer to the "Class CudbTrafficControlManager" section of CUDB Node Configuration Data Model Description, Reference [3].
For more information on the CudbLocalNode class, refer to the "Class CudbLocalNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Example 1 (shown in COM CLI) shows the commands for disabling Provisioning, Traffic, and Site VIP addresses of node 100 with 10.10.10.1 configured as Provisioning VIP, 10.10.10.10 configured as Traffic VIP, and 10.10.10.20 configured as Site VIP.
Example 1 Disabling Addresses
>configure (config)>ManagedElement=1,CudbSystem=1,CudbLocalNode=100,CudbTrafficControlManager=1 (config-CudbTrafficControlManager=1)>adminState=UNLOCKED (config-CudbTrafficControlManager=1)>CudbTrafficBlockingRule=1 (config-CudbTrafficBlockingRule=1)>blockedVIP="10.10.10.1" (config-CudbTrafficBlockingRule=1)>up (config-CudbTrafficControlManager=1)>CudbTrafficBlockingRule=2 (config-CudbTrafficBlockingRule=2)>blockedVIP="10.10.10.10" (config-CudbTrafficBlockingRule=2)>up (config-CudbTrafficControlManager=1)>CudbTrafficBlockingRule=3 (config-CudbTrafficBlockingRule=3)>blockedVIP="10.10.10.20" (config-CudbTrafficBlockingRule=3)>commit (CudbTrafficBlockingRule=3)>up (CudbTrafficControlManager=1)>show all CudbTrafficControlManager=1 adminState=UNLOCKED trafficControlManagerState=ENABLED CudbTrafficBlockingRule=1 blockedVIP="10.10.10.1" CudbTrafficBlockingRule=2 blockedVIP="10.10.10.10" CudbTrafficBlockingRule=3 blockedVIP="10.10.10.20" (CudbTrafficControlManager=1)>exit
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.31 Enabling Provisioning, Traffic, and Site VIP Addresses
To re-enable Provisioning, Traffic, and Site VIP addresses, perform the following steps:
- To list all present blocking rules, show all instances of the CudbTrafficBlockingRule class under the CudbTrafficControlManager class, together with their attributes.
- Remove the blocking rule
for the Provisioning VIP address:
- Identify which blocking rule is for the Provisioning VIP address. To do that, examine the output of Step 1 and look for the instance of the CudbTrafficBlockingRule class where the value of the blockedVIP attribute is equal to the Provisioning VIP address that can be obtained from the network plan.
- Remove the identified instance of the CudbTrafficBlockingRule class.
- Remove the blocking
rule for the Traffic VIP address:
- Identify which blocking rule is for the Traffic VIP address. To do that, examine the output of Step 1 and look for the instance of the CudbTrafficBlockingRule class where the value of the blockedVIP attribute is equal to the Traffic VIP address that can be obtained from the trafficVIP attribute of the CudbLocalNode class.
- Remove the identified instance of the CudbTrafficBlockingRule class.
- Remove the blocking rule
for the Site VIP address:
- Identify which blocking rule is for the Site VIP address. To do that, examine the output of Step 1 and look for the instance of the CudbTrafficBlockingRule class where the value of the blockedVIP attribute is equal to the Site VIP address that can be obtained from the cudbVIP attribute of the CudbLocalNode class.
- Remove the identified instance of the CudbTrafficBlockingRule class.
- Set the value of the adminState attribute of the to CudbTrafficControlManager class to LOCKED.
- Note:
- Make sure that Step 2, Step 3, and Step 4 are executed previously, because adminState cannot be set to LOCKED if there is any blocking rule present.
- Check the trafficControlManagerState attribute of the CudbTrafficControlManager class.
If trafficControlManagerState is DISABLED, then a problem occurred during the activation of the configuration change in the node, and the node behavior cannot be guaranteed to be consistent with the configuration.
For more information on the CudbTrafficBlockingRule class, refer to the "Class CudbTrafficBlockingRule" section of CUDB Node Configuration Data Model Description, Reference [3].
For more information on the CudbTrafficControlManager class, refer to the "Class CudbTrafficControlManager" section of CUDB Node Configuration Data Model Description, Reference [3].
For more information on the CudbLocalNode class, refer to the "Class CudbLocalNode" section of CUDB Node Configuration Data Model Description, Reference [3].
Example 2 (shown in COM CLI) shows the commands for re-enabling all VIP addresses of node 100.
Example 2 Re-Enabling VIP Addresses
>configure (config)>ManagedElement=1,CudbSystem=1,CudbLocalNode=100,CudbTrafficControlManager=1 (config-CudbTrafficControlManager=1)>show all verbose CudbTrafficControlManager=1 adminState=UNLOCKED cudbTrafficControlManagerId="1" trafficControlManagerState=ENABLED <read-only> CudbTrafficBlockingRule=1 blockedVIP="10.10.10.1" cudbTrafficBlockingRuleId="1" CudbTrafficBlockingRule=2 blockedVIP="10.10.10.10" cudbTrafficBlockingRuleId="2" CudbTrafficBlockingRule=3 blockedVIP="10.10.10.20" cudbTrafficBlockingRuleId="3" (config-CudbTrafficControlManager=1)>adminState=UNLOCKED (config-CudbTrafficControlManager=1)>no CudbTrafficBlockingRule=1 (config-CudbTrafficControlManager=1)>no CudbTrafficBlockingRule=2 (config-CudbTrafficControlManager=1)>no CudbTrafficBlockingRule=3 (config-CudbTrafficControlManager=1)>adminState=LOCKED (config-CudbTrafficControlManager=1)>commit (CudbTrafficControlManager=1)>show all CudbTrafficControlManager=1 adminState=LOCKED trafficControlManagerState=ENABLED (CudbTrafficControlManager=1)>exit
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.32 Configuring PG Endpoints in a Local CUDB Node for the Provisioning Assurance Function
PG endpoints are configured in the CUDB nodes as destinations for the Provisioning Assurance function interworking.
- Note:
- This procedure can be performed by Ericsson personnel only. Contact the next level of maintenance support to add new CUDB LDAP users to CUDB nodes.
20.33 Creating a New Notification Event
To create a new CUDB Notification Event, a new instance of the CudbNotificationEvent class must be added to the configuration model and the corresponding attributes must be set. For more information, refer to the "Class CudbNotificationEvent" section of CUDB Node Configuration Data Model Description, Reference [3].
Below is an example, shown in COM CLI, of CudBNotificationEvent=1 with eventId=”SAE-HLR” with defined one Notification Endpoint and five Notification Object Classes:
>show verbose ManagedElement=1,CudbSystem=1,CudbNotifications=1,CudbNotificationEvent=1 CudbNotificationEvent=1 cudbNotificationEventId="1" eventId="SAE-HLR" notificationString="mobilityEvent" userLabel=[] <empty> CudbNotificationEndPoint=1 CudbNotificationObjectClass=1 CudbNotificationObjectClass=2 CudbNotificationObjectClass=3 CudbNotificationObjectClass=4 CudbNotificationObjectClass=5
Define all required elements (attributes, object/object classes and their attributes) of the new CudbNotificationEvent in its tree structure (Directory Information Tree, DIT) before starting to create a new Notification Event.
Following is an example of a new CudbNotificationEvent=2 shown in COM CLI:
>show verbose ManagedElement=1,CudbSystem=1,CudbNotifications=1,CudbNotificationEvent=2 CudbNotificationEvent=2 cudbNotificationEventId="2" eventId="SAE-HSS" notificationString="mobilityEvent" userLabel=[] <empty> CudbNotificationEndPoint=1 CudbNotificationObjectClass=1 >show verbose ManagedElement=1,CudbSystem=1,CudbNotifications=1,CudbNotificationEvent=2,CudbNotificationEndPoint=1 CudbNotificationEndPoint=1 name="Serv1" URI="http://127.0.0.1:8080" webService="/" weight=1 >show verbose ManagedElement=1,CudbSystem=1,CudbNotifications=1,CudbNotificationEvent=2,CudbNotificationObjectClass=1 CudbNotificationObjectClass=1 cudbNotificationObjectClassId="1" dn="serv=csps" name="CsPsLocationData" type="related" userLabel=[] <empty> CudbNotificationAttr=1 >show verbose ManagedElement=1,CudbSystem=1,CudbNotifications=1,CudbNotificationEvent=2,⇒ CudbNotificationObjectClass=1,CudbNotificationAttr=1 CudbNotificationAttr=1 cudbNotificationAttrId="1" name="SGSNNUM" send=true userLabel=[] <empty> value="" (CudbNotificationObjectClass=1)>
As shown above, CudbNotificationEvent=2 will contain one CudbNotificationEndpoint=1 and one CudbNotificationObjectClass=1 with one CudbNotificationAttr=1.
Follow the steps below, shown in COM CLI, to insert a new Notification Event using the Object Model Modification procedure:
- Establish a CUDB CLI session towards the CUDB node by
executing the ssh -l cudbadmin <CUDB_Node_OAM_IP_Address> command.
Important: This procedure must be done in all CUDB nodes in the system.
- If there is no backup of the present configuration, perform the backup by executing the sudo cmw-configuration-persist command. If the backup is already updated, proceed to Step 3.
- Establish a CUDB configuration CLI session
in the active SC. Use the commands below (their output is also shown)
to find the active SC:
sudo cudbHaState | grep COM | grep ACTIVE
COM is assigned as ACTIVE in controller SC-1The active SC, (SC_2_1 in the example above) must be used for accessing the COM CLI by executing the sudo /opt/com/bin/cliss command.
- Set the configuration session by executing the configure command.
- Check if CudbNotifications are
already enabled and exist in CudbNotificationsEvents.
Use the show verbose command to show ManagedElement=1,CudbSystem=1,CudbNotifications=1:
(config)>show verbose ManagedElement=1,CudbSystem=1,CudbNotifications=1
CudbNotifications=1
cudbNotificationsId="1"
enabled=true <default>
maxReattempts=3 <default>
reattemptTime=1000 <default>
userLabel=[] <empty>
CudbNotificationEvent=1
(config)>If CudbNotifications are not already enabled, execute the following commands:
(config)>ManagedElement=1,CudbSystem=1,CudbNotifications=1,enabled=true
(config)>commit - Execute the following command sequence to add a new CUDB
Notification Event (CudbNotificationEvent=2) in the CUDB configuration
model:
- Note:
- This is an example and must not be taken as a rule.
>configure
(config)>ManagedElement=1,CudbSystem=1,CudbNotifications=1,CudbNotificationEvent=2
(config-CudbNotificationEvent=2)>eventId=SAE-HSS
(config-CudbNotificationEvent=2)>notificationString=mobilityEvent
(config-CudbNotificationEvent=2)>CudbNotificationEndPoint=1
(config-CudbNotificationEndPoint=1)>name=Serv1
(config-CudbNotificationEndPoint=1)>URI=http://127.0.0.1:8080
(config-CudbNotificationEndPoint=1)>weight=1
(config-CudbNotificationEndPoint=1)>up
(config-CudbNotificationEvent=2)>CudbNotificationObjectClass=1
(config-CudbNotificationObjectClass=1)>dn="serv=csps"
(config-CudbNotificationObjectClass=1)>name=CsPsLocationData
(config-CudbNotificationObjectClass=1)>type=related
(config-CudbNotificationObjectClass=1)>CudbNotificationAttr=1
(config-CudbNotificationAttr=1)>name=SGSNNUM
(config-CudbNotificationAttr=1)>send=true
(config-CudbNotificationAttr=1)>up
(config-CudbNotificationObjectClass=1)>up
(config-CudbNotificationEvent=2)>show verbose
CudbNotificationEvent=2
cudbNotificationEventId="2"
eventId="SAE-HSS"
notificationString="mobilityEvent"
userLabel=[] <empty>
CudbNotificationEndPoint=1
CudbNotificationObjectClass=1Each operation is executed as a unique transaction.
- Commit the changes by executing the commit command.
- Check the log files to see the result of the operations. For more information, see CUDB Node Logging Events, Reference [7].
- Check the configuration changes with the show ManagedElement=1,CudbSystem=1,CudbNotificationEvent=2 command.
- Note:
- Remember to use show verbose instead of show for not mandatory attributes that must have no set value, or for optional attributes whose value is set to the default one.
- Exit from the configuration mode by executing the end command.
- Exit from the CUDB configuration CLI console by executing the exit command.
- Note:
- Configuration changes in the examples above can also be performed through the NETCONF client.
Refer to CUDB Notifications, Reference [18] for more information about Notifications Parameters.
Refer to the Object Model Modification Procedure in CUDB Node Configuration Data Model Description, Reference [3] for more information on all the steps required to modify the object model (for example, on using the administrative operation applyConfig to activate the changes).
20.34 Configuring QoS in CUDB
In CUDB the Differentiated Services (DiffServ) computer networking architecture is used to provide QoS (Quality of Service). The basic principle of DiffServ is the classification of IP packets by applying a special marking on them, that is placing a DSCP mark in the IPv4 TOS field. Based on this mark, the DiffServ-Aware routers in the DiffServ domain can handle the traffic (Per Hop Behavior) depending on the traffic class which the packet belongs to. After that, QoS is provided by iptables. Using this method, the outgoing packages are marked with the preconfigured DSCP values. Refer to CUDB Node Network Description, Reference [12] for more information on the preconfigured values.
- Note:
- Configuring QoS is restricted to Ericsson personnel. Contact the next level of maintenance support to perform such procedures.
Glossary
For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [22].
Reference List
| CUDB Documents |
|---|
| [1] CUDB Node Commands and Parameters. |
| [2] CUDB Users and Passwords, 3/00651-HDA 104 03/9 |
| [3] CUDB Node Configuration Data Model Description. |
| [4] CUDB Node Fault Management Configuration Guide. |
| [5] CUDB Counters List. |
| [6] CUDB Performance Guide. |
| [7] CUDB Node Logging Events. |
| [8] CUDB Security and Privacy Management. |
| [9] CUDB Backup and Restore Procedures. |
| [10] CUDB Node Preventive Maintenance. |
| [11] CUDB Data Storage Handling. |
| [12] CUDB Node Network Description. |
| [13] CUDB Import and Export Procedures. |
| [14] CUDB LDAP Schema Management Graphical User Interface. |
| [15] CUDB Health Check. |
| [16] CUDB High Availability. |
| [17] CUDB Multiple Geographical Areas. |
| [18] CUDB Notifications. |
| [19] CUDB Subscription Reallocation. |
| [20] CUDB LDAP Interwork Description. |
| [21] CUDB LDAP Data Views Management. |
| [22] CUDB Glossary of Terms and Acronyms. |
| Other Ericsson Documents |
|---|
| [23] COM Management Guide. |
| [24] COM NETCONF Interface Base. |
| [25] LDE Management Guide. |
| [26] eVIP Management Guide. |
| Other Documents and Online References |
|---|
| [27] OpenLDAP, ldapsearch Tool Manual. |

Contents