1 Introduction
This instruction concerns alarm handling for the Licensing, Capacity Usage Threshold Reached, Major alarm.
1.1 Alarm Description
This alarm is raised when the reserved capacity limit in a capacity license has been reached.
The alarm is issued in the following situations:
- The capacity usage limit has been reached for the Payload Blades / Virtual Machines.
- The capacity usage limit has been reached for the HLR Profile.
- The capacity usage limit has been reached for the HSS-IMS Profile.
- The capacity usage limit has been reached for the HSS-EPC Profile.
- The capacity usage limit has been reached for the AUC Profile.
- The capacity usage limit has been reached for the Small Generic Profile.
- The capacity usage limit has been reached for the Medium Generic Profile.
- The capacity usage limit has been reached for the Large Generic Profile.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The licence capacity limit of the capacity profile license has been reached. |
The capacity usage limit has been reached. |
The requested capacity has reached the total licensed capacity defined in the capacity profile license. |
License Manager |
Violation of license agreements. |
|
The license capacity limit of the Payload Blades / Virtual Machines capacity license has been reached. |
The capacity usage limit has been reached. |
The requested capacity has reached the total licensed capacity defined in the Payload Blades / Virtual Machines capacity license. |
License Manager |
Additional capacity exceeding the usage limit is unavailable. |
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
Yes |
|
Module |
LICENSING |
|
Error Code |
6 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raise. |
|
Resource ID |
1.3.6.1.4.1.193.169.14.2.3.<# SUB_LICENSE_SUFFIX> |
|
Alarm Model Description |
License Management, Licensing |
|
Alarm Active Description |
Capacity Usage Threshold Reached for <#LICENSE_TYPE>, Major |
|
ITU Alarm Event Type |
qualityOfServiceAlarm (3) |
|
ITU Alarm Probable Cause |
thresholdCrossed (549) |
|
ITU Alarm Perceived Severity |
(4) – Major |
|
Originating source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which the alarms are raised. |
The available values of the <#SUB_LICENSE_SUFFIX> and <#LICENSE_TYPE> variables shown in Table 2 are listed
below. The list follows the below format:
"<#SUB_LICENSE_SUFFIX>" for the <#LICENSE_TYPE>.
- "1" for the Payload Blades / VMs.
- "2" for the HLR Profile.
- "3" for the HSS-IMS Profile.
- "4" for the HSS-EPC Profile.
- "5" for the AUC Profile.
- "6" for the Small Generic Profile.
- "7" for the Medium Generic Profile.
- "8" for the Large Generic Profile.
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
- CUDB Node Fault Management Configuration Guide, Reference [1], regarding alarm configuration.
- System Safety Information, Reference [3]
- Personal Health and Safety Information, Reference [4]
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
If the alarm is raised, then refer to the License Management, Capacity Usage Threshold Reached, Reference [5] document for the procedure to perform.
- Note:
- Perform only the actions that are applicable for LM deployments using ELIM license key files. The applicable severity is "Major".
Glossary
For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [2].
Reference List
| CUDB Documents |
|---|
| [1] CUDB Node Fault Management Configuration Guide. |
| [2] CUDB Glossary of Terms and Acronyms. |
| Other Ericsson Documents |
|---|
| [3] System Safety Information. |
| [4] Personal Health and Safety Information. |
| [5] License Management, Capacity Usage Threshold Reached. |

Contents