SAF, AMF Component Cleanup Failed
Ericsson Centralized User Database

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

Reference List

1   Introduction

This instruction concerns alarm handling for the SAF, AMF Component Cleanup Failed alarm.

1.1   Alarm Description

This alarm is associated with the Service Availability Forum (SAF). Refer to CUDB Node Fault Management Configuration Guide, Reference [1] for more details.

For information on the possible alarm causes and the corresponding fault reasons, fault locations, and impacts, refer to COM SA, AMF Component Cleanup Failed, Reference [2].

The alarm attributes are listed and explained in Table 1.

Table 1    Alarm Attributes

Attribute Name

Attribute Value

Auto Cease

No

Module

SAF

Error Code

1

Timestamp First

Date and time when the alarm was raised for the first time.

Repeated Counter

Number which indicates how many times the alarm was raised.

Timestamp Last

Date and time of the most recent alarm raise.

Resource ID

.1.3.6.1.4.1.193.169.9.1. <length>.<NOI>

Alarm Model Description

AMF Component Cleanup Failed, SAF

Alarm Active Description

SAF platform: Component Cleanup Failed @<NON>

ITU Alarm Event Type

other (1)

ITU Alarm Probable Cause

softwareProgramError (546)

ITU Alarm Perceived Severity

(3) – Critical

Originating Source IP

Node IP where the alarm was raised.

Sequence Number

Number which indicates the order in which the alarms are raised.

For further information about field descriptions refer to CUDB Node Fault Management Configuration Guide, Reference [1].

In Table 1, the indicated variables are as follows:

1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that you have read the following documents:

1.2.2   Tools

Not applicable.

1.2.3   Conditions

Not applicable.

2   Procedure

Do the following:

  1. In a first approach, the alarm can be cleared with the previous <NON>, <NOI> and <length> and the following command:

    If the alarm is on SC 1: cmw-alarm-clear cleanup ManagedElement=1,SaAmfApplication.safApp=ERIC-CUDB_CUDBOI,SaAmfSG.safSg=2N,SaAmfSU.safSu=SC-1,SaAmfComp.safComp=CUDBOI

    If the alarm is on SC 2: cmw-alarm-clear cleanup ManagedElement=1,SaAmfApplication.safApp=ERIC-CUDB_CUDBOI,SaAmfSG.safSg=2N,SaAmfSU.safSu=SC-2,SaAmfComp.safComp=CUDBOI

    Refer to Core MW Management Guide, Reference [5] for more information on the cmw-alarm-cease command.

  2. For further details, follow the instructions specified in COM SA, AMF Component Cleanup Failed, Reference [2]. Refer to Core MW Management Guide, Reference [5] for more information on the commands used in the procedure.
  3. Further actions are outside the scope of this Operating Instruction.

Reference List

CUDB Documents
[1] CUDB Node Fault Management Configuration Guide.
Other Ericsson Documents
[2] COM SA, AMF Component Cleanup Failed.
[3] System Safety Information.
[4] Personal Health and Safety Information.
[5] Core MW Management Guide.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    SAF, AMF Component Cleanup Failed         Ericsson Centralized User Database