1 Overview
1.1 Description
The alarm is issued when the Ericsson Centralized User Database (CUDB) tries to send a notification about a started or finished backup procedure to the Provisioning Gateway (PG), but the sending fails.
The alarm attributes are listed and explained in Table 1:
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
No |
|
Module |
STORAGE-ENGINE |
|
Error Code |
16 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raised. |
|
Resource ID |
.1.3.6.1.4.1.193.169.1.3.1 |
|
Alarm Model Description |
Backup Notification to PG Failed, Storage Engine. |
|
Alarm Active Description |
Storage Engine: Notification to PG Failed. |
|
ITU Alarm Event Type |
communicationsAlarm (2) |
|
ITU Alarm Probable Cause |
communicationsSubsystemFailure (505) |
|
ITU Alarm Perceived Severity |
(4) – Major |
|
Originating Source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which alarms were raised. |
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].
The possible causes of the alarm are as follows:
- Wrong PG server definition.
- Network connection problems.
1.2 Prerequisites
1.2.1 Documents
Refer to CUDB System Administrator Guide, Reference [2] for further information.
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
Perform the following steps:
- Check the PG server definition, refer to CUDB System Administrator Guide, Reference [2] for information about PG node configuration. In case of wrong configuration, configure again in a proper way.
- Check the network connections and fix them. The network connection failures are out of these scope of this Operation Instruction.
- If one of the previous problems has been fixed, clear the alarm manually according to the procedure detailed in CUDB Node Fault Management Configuration Guide, Reference [1].
- Manually notify the PG to resume the provisioning process
by executing the following command:
cudbResumeProvisioningNotification
- If the alarm is raised again, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
Glossary
For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [3].
Reference List
| CUDB Documents |
|---|
| [1] CUDB Node Fault Management Configuration Guide. |
| [2] CUDB System Administrator Guide. |
| [3] CUDB Glossary of Terms and Acronyms. |