1 Overview
The purpose of this document is to provide system administrators clear operating instructions for recovering from a node failure or IP network loss, and to make traffic or provisioning available until the CUDB site or IP network becomes operational again.
1.1 Description
This document describes the Partial Recovery procedure that can be used as an emergency work-around solution for both available redundancy configurations. These configurations are as follows:
- 1+1 double geographically redundant CUDB system, with two sites. For more information, refer to CUDB High Availability, Reference [1].
- 1+1+1 triple geographically redundant CUDB system, with three sites. For more information, refer to CUDB High Availability, Reference [1].
1.2 Prerequisites
The procedure can be applied in the following situations:
- Symmetrical split situation.
- In case of 1+1 double redundancy, one site is down for a long time. A site is considered down if all the nodes of the sites are down. If the surviving site is not hosting the master instance for PLDB, update operations from any Provisioning user are rejected. For more information, refer to CUDB High Availability, Reference [1].
- In case of 1+1 double redundancy, an IP backbone failure isolates the sites from each other. One of the sites is not hosting the master instance for PLDB. Update operations from any Provisioning user are rejected in that site. Apply procedure to recover provisioning traffic through that specific site.
- In case of 1+1+1 triple redundancy, one site fails, leaving the rest of the system in majority. After that, an IP backbone failure isolates the remaining sites from each other. Same as previous situation.
- Minority situation.
- In case of 1+1+1 triple redundancy, two of the sites are down for a long time.
- In case of 1+1+1 triple redundancy, a simultaneous IP backbone failure isolates the three sites from each other.
- Note:
- Do not execute the procedures of this document in case of a majority situation.
To detect the detailed situations above, check the following alarms in the CUDB system:
- Minority situation:
In this situation, two Control, Remote Site Unreachable, Reference [2], alarms are raised, one for each unreachable site. In case two of the sites are down, these alarms are only raised on the surviving site. In case the three sites are isolated among them, these alarms are raised on all the sites. This alarm is raised in the node where the System Monitor (SM) leader is located.
- Symmetrical split situation:
In this situation, the Control, Remote Site Unreachable, Reference [2], and Control, Potential Split Brain Detected, Reference [3] alarms are raised on the surviving sites.
For more information, refer to Control, Remote Site Unreachable, Reference [2], and Control, Potential Split Brain Detected, Reference [3].
In any other situation, the system is in majority situation, and the Partial Recovery procedure cannot be applied.
The system must satisfy all the conditions listed above: in case of any differences in the setup, the instructions of this document are not applicable.
As a result of this procedure, the PLDB and DSG masterships are moved to the surviving CUDB site to recover provisioning.
The partial recovery procedure consists of two procedures:
- An Emergency Procedure, which must be applied when the symmetrical split or minority situation occurs.
- A Recovery Procedure, which must be applied when the split situation ends, so that all sites are operational.
The Selective Replica Check and Data Repair processes are part of the Automatic Handling of Network Isolation function. The aim of this automatic process in CUDB is to attempt to handle and repair data loss that happened due to network split or unexpected PLDB or DSG mastership change. For more information on the Selective Replica Check and Data Repair processes, refer to CUDB Data Storage Handling, Reference [5].
1.3 Typographic Conventions
Typographic conventions can be found in the following document:
2 Procedure in Case of Site Failure
This section describes the procedure to follow in case of site failure.
2.1 Situations
This procedure can be applied in the following situations:
- Situation 1: In a 1+1 double geographical redundant CUDB system, one site fails (symmetrical split situation).
- Situation 2: In
a 1+1+1 triple geographical redundant CUDB system, two sites fail
(minority situation).
In Situation 2, the site in minority cannot handle any kind of traffic. To allow traffic operations only over DSGs, go to Section 2.2.2.
In both cases, the surviving site is not hosting the master instance for PLDB. Update operations from any Provisioning user are rejected.
2.2 Emergency Procedure
This section describes the emergency procedure for provisioning recovery and traffic recovery.
2.2.1 Enabling Provisioning
In the situations listed in Section 2.1, only one site is alive in the CUDB system. This site is called the "surviving site". Perform the following steps in case of site failure:
- Make sure that the failing CUDB sites cannot
join to the CUDB system in an uncontrolled manner during the execution
of the procedure.Warning!
This preparatory step must be performed to avoid any potential conflicts and interference from the failed sites during the execution of the procedure.
- Execute the cudbTakeAllMasters command.
- Only applicable in Situation 1.
Only if the surviving site does not host the PLDB master, execute the cudbTakeAllMasters command on any CUDB node of the surviving site. For more information, refer to CUDB Node Commands and Parameters, Reference [4].
- Only applicable in Situation 2.
Execute the cudbTakeAllMasters command on any CUDB node of the surviving site. For more information, refer to CUDB Node Commands and Parameters, Reference [4].
- Only applicable in Situation 1.
- After the above command has been executed,
provisioning must be available.Warning!
After successful command execution, provisioning continues. However, the system is not geographically redundant, so the missing sites and the system backbone must be restored immediately. The system recovers geographical redundancy after the recovery procedure (described in Section 2.3) is executed.
2.2.2 Enabling Traffic
Only applicable in Situation 2.
To allow the traffic operations in the DSGs, execute the cudbServiceContinuity command in the surviving site by performing the following steps.
- Note:
- The cudbServiceContinuity command does not avoid that this site could be chosen later as “surviving
site” to recover the provisioning (see Section 2.2.1).
If the automaticServiceContinuity parameter is enabled, this will be done automatically (for more information, refer to CUDB High Availability, Reference [1]).
- Execute the cudbServiceContinuity command on one node (and only one node) of the surviving site. For
more information, refer to CUDB Node Commands and Parameters, Reference [4].Warning!
This command cannot be undone: once it is executed, the DSG masterships are moved to the surviving site. Killing the command during waiting does not stop the process of taking the mastership.
- After the above command has been executed, traffic must be available in all DSGs.
- To recover the provisioning, execute the specific emergency procedure (see Section 2.2.1).
2.3 Recovery Procedure
When the failed sites are working again, perform the following steps to make sure the original geographical redundancy configuration (either 1+1 double, or 1+1+1 triple geographical redundancy) is recovered:
- Before connecting the CUDB nodes in the failed
sites to the CUDB system, set the PLDB and all the DS Units in each
node to maintenance mode executing the following command in each of
the nodes of the failed sites:
cudbManageStore -a -o maintenance
- Use the following
command to check which node runs the SM leader:
cudbSystemStatus -B
- Check that the Control, Remote Site Unreachable, Reference [2], alarm is not raised. To do so, login to the node where the SM leader
is located, and check for the alarms raised in the node with the following
command:
cudbSystemStatus -a
If the Control, Remote Site Unreachable, Reference [2], alarm is raised, then the original 1+1 double geographical redundant or 1+1+1 triple geographical redundant CUDB system is not yet recovered. Check that the nodes in the failed sites are properly connected to the CUDB system.
- To set all the PLDB and DS Units to ready,
execute the following command in each node of the failed sites:
cudbManageStore -a -o ready
- At this point, the PLDB and the DS Units
in the nodes of the failed sites become slaves of the master PLDB
and master DS Units hosted in the surviving site, and start to gather
the differences from the masters. Check the replication status of
the nodes by executing the following command:
cudbSystemStatus -R
- If a slave database cluster is unable to
sync with the current master, check if Storage Engine, Unable to Synchronize Cluster in DS, Major, Reference [7] or Storage Engine, Unable to Synchronize Cluster in PLDB, Major, Reference [8] is raised. In those cases, execute the following command to restore
the slave DS Unit or PLDB where the replication is not running:
cudbUnitDataBackupAndRestore
For more information, refer to CUDB Backup and Restore Procedures, Reference [9].
- Note:
- In case the Automatic Handling of Network Isolation or the
Self-Ordered Backup and Restore functions or both are enabled, alarms
related to these functions will appear before the Storage Engine, Unable to Synchronize Cluster in DS, Major, Reference [7] or Storage Engine, Unable to Synchronize Cluster in PLDB, Major, Reference [8].
In case if Self-Ordered Backup and Restore process restores the replication automatically, these alarms will not be raised at all.
Once the replication is working, if needed, move the DSG mastership to the desired node by using the cudbDsgMastershipChange command, taking into account if Automatic Mastership Change function is active.
For more information about the commands used in this section, refer to CUDB Node Commands and Parameters, Reference [4]. For more information on the Automatic Handling of Network Isolation procedure, refer to CUDB High Availability, Reference [1].
3 Procedure in Case of IP Backbone Failure
This section describes the procedure to follow in case of an IP backbone failure.
3.1 Situation
This procedure can be applied in the following situations:
- Situation 1: In a 1+1 double geographical redundant CUDB system, an IP backbone failure isolates the sites from each other (symmetrical split situation).
- Situation 2: In a 1+1+1 triple geographical redundant CUDB system, one site fails, leaving the rest of the system in majority. After that, an IP backbone failure isolates the remaining sites from each other (symmetrical split situation).
- Situation 3: In a 1+1+1 triple geographical redundant CUDB system, an IP backbone failure isolates the sites from each other causing all nodes to be in minority.
- Situation 4: In a 1+1+1 triple geographical redundant CUDB system, an IP backbone failure isolates one site from the others, being two sites in majority and the other one in minority.
In Situations 1 and 2, one of the sites is not hosting the master instance for PLDB. Update operations from any Provisioning user are rejected in that site. Apply procedure to recover provisioning traffic through that specific site.
In Situation 3, there are no master instances either for PLDB or any DSG in any of the sites.
In Situation 4, there are no master instances either for PLDB or any DSG in the site in minority.
In Situations 3 and 4, the site in minority cannot handle any kind of traffic. To allow traffic operations only over DSGs, go to Section 3.2.2.
3.2 Emergency Procedure
In case of the situations described in Section 3.1, the sites in the system are alive, but are isolated from each other (except Situation 2, where two sites are alive, and one is down). Therefore, the site where full service is to be granted (traffic and provisioning) must be chosen as the "surviving site". Execute the below procedure on the surviving site.
3.2.1 Enabling Provisioning
This procedure is only applicable to Situations 1 and 2.
If Selective Replica Check and Data Repair are enabled, after the backbone problem is fixed and the sites are rejoined, Automatic Handling of Network Isolation fixes data inconsistencies caused by the split and re-establishes replication in the slave replicas, so there is no need to select a surviving site. For more information on Automatic Handling of Network Isolation, please refer to CUDB Automatic Handling of Network Isolation Output Description, Reference [6].
If Selective Replica Check and Data Repair are disabled, perform the following:
Execute the below procedure only on one node of the selected surviving site. Disable the rest of the sites, so that they do not join the system during the execution of the procedure. The execution of this procedure on the remote nodes leads to data inconsistency and data loss without any rollback possibility.
Do not select an unstable node in the surviving site. The node selected to execute the below steps in the surviving site must be free of Operating System (OS) alarms and SAF alarms.- Set the PLDB and DS Units to maintenance
mode in all nodes on the sites not selected as the surviving site.
Use the following command to do so:
cudbManageStore -a -o maintenance
Warning!As the IP backbone is down, this step must be performed locally on-site by the operator (no remote configuration is available). Therefore, operators must be prepared to execute the below commands on remote nodes as well in time. Ericsson takes no responsibility for any data inconsistency if the commands in this step are not executed in time, or at all.
- Only if the PLDB master is not in the surviving site, execute the cudbTakeAllMasters command on one node (and only one node) of the surviving site. For more information refer to CUDB Node Commands and Parameters, Reference [4].
- After the above command has been executed,
provisioning must be available.Warning!
After successful command execution, provisioning continues. However, the system is not geographically redundant, so the missing sites and the system backbone must be restored immediately. The system recovers geographical redundancy after the recovery procedure (described in Section 3.3) is executed.
This procedure is only applicable to Situation 3.
If Selective Replica Check and Data Repair are enabled, perform the following:
Do not select an unstable node. The node selected to execute the below steps must be free of OS and SAF alarms.
- Execute the cudbTakeAllMasters command on one node (and only one node) of the site where provisioning is to be enabled. For more information, refer to CUDB Node Commands and Parameters, Reference [4].
- After the above command has been executed,
provisioning must be available.Warning!
After successful command execution, provisioning continues. However, the system is not geographically redundant, so the missing sites and the system backbone must be restored immediately. The system recovers geographical redundancy after the recovery procedure (described in Section 3.3) is executed.
If Selective Replica Check and Data Repair are disabled, perform the following:
Execute the below procedure only on one node of the selected surviving site. Disable the rest of the sites, so that they do not join the system during the execution of the procedure. The execution of this procedure on the remote nodes leads to data inconsistency and data loss without any rollback possibility.
Do not select an unstable node in the surviving site. The node selected to execute the below steps in the surviving site must be free of OS and SAF alarms.- Set the PLDB and DS Units to maintenance
mode in all nodes on the sites not selected as the surviving site.
Use the following command to do so:
cudbManageStore -a -o maintenance
Warning!As the IP backbone is down, this step must be performed locally on-site by the operator (no remote configuration is available). Therefore, operators must be prepared to execute the below commands on remote nodes as well in time. Ericsson takes no responsibility for any data inconsistency if the commands in this step are not executed in time, or at all.
- Execute the cudbTakeAllMasters command on one node (and only one node) of the surviving site. For more information, refer to CUDB Node Commands and Parameters, Reference [4].
- After the above command has been executed,
provisioning must be available.Warning!
After successful command execution, provisioning continues. However, the system is not geographically redundant, so the missing sites and the system backbone must be restored immediately. The system recovers geographical redundancy after the recovery procedure (described in Section 3.3) is executed.
3.2.2 Enabling Traffic
This procedure is only applicable in Situations 3 and 4.
To allow the traffic operations in the DSGs, execute the cudbServiceContinuity command in the site in minority by performing the following steps.
- Note:
- The cudbServiceContinuity command does not
avoid that this site could be chosen later as “surviving site”
to recover the provisioning (see Section 3.2.1).
If the automaticServiceContinuity parameter is enabled, this will be done automatically (for more information, refer to CUDB High Availability, Reference [1]).
As the IP backbone is down, this step must be performed locally on-site by the operator (no remote configuration is available).
- Execute the cudbServiceContinuity command on one node (and only one node) of the surviving site. For
more information, refer to CUDB Node Commands and Parameters, Reference [4].Warning!
This command cannot be undone: once it is executed, the DSG masterships are moved to the surviving site. Killing the command during waiting does not stop the process of taking the mastership.
- After the above command has been executed, traffic must be available in all DSGs.
- To recover the provisioning in this site, execute the specific emergency procedure (see Section 3.2.1).
3.3 Recovery Procedure
When the IP Backbone is working again, follow the steps below to restore the original redundancy configuration:
- Note:
- In case the Selective Replica Check and Data Repair were enabled while performing the procedures in Section 3.2, skip until Step 5.
- Use the
following command to check which node runs the SM leader:
cudbSystemStatus -B
- Check that the Control, Remote Site Unreachable, Reference [2], alarm is not raised. To do so, login to the node where the SM leader
is located, and check for the alarms raised in the node with the following
command:
cudbSystemStatus -a
If the Control, Remote Site Unreachable, Reference [2], alarm is raised, then the original 1+1 double geographical redundant or 1+1+1 triple geographical redundant CUDB system is not yet recovered. Check that the nodes in the failed sites are properly connected to the CUDB system.
- To set all the PLDB and DS Units to ready,
execute the following command in all the nodes of the sites not selected
as the surviving site:
cudbManageStore -a -o ready
- At this point in time, the PLDB and the DS
Units in the nodes of the failed sites become slaves of the master
PLDB and master DS Units hosted in the surviving site, and start to
gather the differences from the masters. Check the replication status
of the nodes by executing the following command:
cudbSystemStatus -R
- If a slave database
cluster is unable to sync with the current master, check if Storage Engine, Unable to Synchronize Cluster in DS, Major, Reference [7] or Storage Engine, Unable to Synchronize Cluster in PLDB, Major, Reference [8] is raised. In those cases, execute the following command to restore
the slave DS Unit or PLDB where the replication is not running:
cudbUnitDataBackupAndRestore
For more information, refer to CUDB Backup and Restore Procedures, Reference [9].
- Note:
- In case the Automatic Handling of Network Isolation or the
Self-Ordered Backup and Restore functions or both are enabled, alarms
related to these functions will appear before the Storage Engine, Unable to Synchronize Cluster in DS, Major, Reference [7] or Storage Engine, Unable to Synchronize Cluster in PLDB, Major, Reference [8].
In case if Self-Ordered Backup and Restore process restores the replication automatically, these alarms will not be raised at all.
Once the replication is working, if needed, move the DSG mastership to the desired node by using the cudbDsgMastershipChange command, taking into account if Automatic Mastership Change function is active.
For more information about the commands used in this section, refer to CUDB Node Commands and Parameters, Reference [4]. For more information on the Automatic Handling of Network Isolation procedure, refer to CUDB High Availability, Reference [1].
Glossary
For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [10].