1 Introduction
This document describes the License Management, Capacity Usage Threshold Reached alarm and provides instructions for fault management.
1.1 Alarm Description
License Management, Capacity Usage Threshold Reached is raised when the number of reserved tokens in a capacity license approaches the licensedCapacityLimit.
This primary alarm is issued by the ManagedElement=1,SystemFunctions=1,Lm=1,LicenseId=<licenseId> Managed Object (MO).
Possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault |
Impact |
|---|---|---|---|---|
|
351 |
License Management, Capacity Usage Threshold Reached |
Requested capacity has exceeded the |
LM Server |
Requested capacity may be unavailable. |
The following consequences are expected if the alarm condition is not resolved:
- The application may not be able to use additional instances of the licensed feature.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
activeSeverity |
WARNING: The reserved capacity of the license identified by the CapacityKey.capacityKeyId has passed the warning threshold defined by the Lm.capacityAlarmThreshold parameter but is still below the total licensed capacity. MAJOR: The CapacityKey.licensedCapacityLimit of the license identified by the capacityKeyId has been reached.
|
|
additionalInfo |
N/A
|
|
additionalText |
"Capacity usage threshold reached"
|
|
eventType |
QUALITYOFSERVICEALARM
|
|
lastEventTime |
A timestamp of the last alarm update, such as an alarm status change or severity change.
|
|
majorType |
193
|
|
minorType |
393219
|
|
originalAdditionalText |
Content of the additionalText field when the alarm was raised.
|
|
originalEventTime |
Timestamp when the alarm was raised.
|
|
originalSeverity |
Value of the activeSeverity level when the alarm was raised.
|
|
probableCause |
351 (x733 Threshold Crossed)
|
|
sequenceNumber |
The notification identity for this object instance. It is not the same as the fmAlarmId since multiple notifications may be sent for one alarm instance. This value changes for every notification (such as a severity change, alarm clear, and so on).
|
|
source |
ManagedElement=1,SystemFunctions=1,Lm=1,License=<licenseId>
|
|
specificProblem |
License Management, Capacity Usage Threshold Reached
|
1.2 Prerequisites
This section lists the prerequisite documents, tools, and conditions for the alarm handling procedure.
1.2.1 Documents
Review the following documents before starting the procedure:
- Personal Health and Safety Information (Reference [1])
- System Safety Information (Reference [2])
- The user guide for your LM deployment:
- "Installing License Key Files" in the LM User Guide for Sentinel RMS (Reference [3])
- "Installing License Key Files" in the LM User Guide for ELIM (Reference [4])
- "Obtaining License Key Files" in the LM User Guide for Arwa (Reference [5])
- "Configuration Management Using CLI" in the COM Management Guide for your version of the product software.
1.2.2 Tools
Ensure that the following tools are available before starting the procedure:
For more information on these tools, refer to the documentation for your version of the product software.
1.2.3 Conditions
Ensure that the following conditions are met before starting the procedure:
- Know the IP address of the blade where the active COM CLI is running.
- Have the proper authority to handle configuration management of the network elements.
- Be familiar with basic UNIX commands.
2 Procedure
This section describes the alarm handling procedure.
2.1 Analyzing the Alarm
The License Management, Capacity Usage Threshold Reached alarm will clear automatically when the reserved capacity drops below the Lm.capacityAlarmThreshold minus a hysteresis value defined by the Lm.capacityAlarmHysteresis configuration parameter. For more information about Lm.capacityAlarmThreshold and Lm.capacityAlarmHysteresis, refer to "Configuration Management" in the user guide for your LM deployment.
- LM User Guide for Sentinel RMS (Reference [3])
- LM User Guide for ELIM (Reference [4])
- LM User Guide for Arwa (Reference [5])
If the alarm persists, or if it is triggered frequently, adjusting the LM configuration, ordering a new license with higher capacity, or both may be required.
To better determine the fault location and cause do the following:
- From a terminal window, use ssh to connect to the COM
CLI Management System server port (default 22) on the blade where
the active COM CLI is running:
ssh <username>@<blade_IP_address> -p 22 -t -s cli
The COM CLI opens after supplying your password.
- Retrieve the current percentage value of the capacityAlarmHysteresis configuration parameter:
show verbose ManagedElement=1, SystemFunctions=1, Lm=1, capacityAlarmHysteresis
- Retrieve the current percentage value of the capacityAlarmThreshold configuration parameter:
show verbose ManagedElement=1, SystemFunctions=1, Lm=1, capacityAlarmThreshold
- Retrieve information about the affected capacity license:
ManagedElement=1, SystemFunctions=1, Lm=1
show --moc CapacityKey --condition (keyId=="<licenseId>")
Where <licenseId> is the license identify from the alarm source. For example:
(Lm=1)>show --moc CapacityKey --condition (keyId=="FAT1020383") CapacityKey=1 capacityUnit="token" expiration="2016-10-1" grantedCapacityLevel=900 keyId="FAT1020383" licensedCapacityLimitReached=false name="FAT1020383" productType="" validFrom="2014-3-5" version="1.0" licensedCapacityLimit value=1000 - Provide the LM configuration and license information for
capacity planning.
- After obtaining a work order to adjust the LM configuration, refer to Section 2.2.
- After obtaining a work order for a new license with higher capacity, refer to Section 2.3 or Section 2.4.
2.2 Actions to Adjust the LM Configuration
After obtaining a work order to adjust the LM configuration:
- From a terminal window, use ssh to connect to the COM
CLI Management System server port (default 22) on the blade where
the active COM CLI is running:
ssh <username>@<blade_IP_address> -p 22 -t -s cli
The COM CLI opens after supplying your password.
- Verify that the capacityAlarmHysteresis configuration parameter has the proper value:
show verbose ManagedElement=1, SystemFunctions=1, Lm=1, capacityAlarmHysteresis
- If required, set a new percentage value for Lm.capacityAlarmHysteresis with the following commands:
configure
ManagedElement=1, SystemFunctions=1, Lm=1, capacityAlarmHysteresis=<n>
Where <n> is the new parameter value.
commit
- Verify that the capacityAlarmThreshold configuration parameter has the proper value:
show verbose ManagedElement=1, SystemFunctions=1, Lm=1, capacityAlarmThreshold
- If required, set a new percentage value for capacityAlarmThreshold with the following commands:
configure
ManagedElement=1, SystemFunctions=1, Lm=1, capacityAlarmThreshold=<n>
Where <n> is the new parameter value.
commit
- Check the alarm status.
If the alarm is still active, or if it is triggered frequently, a new license with higher capacity may be required.
2.3 Actions to Order and Install a New License Key File
- Note:
- This procedure only applies to Sentinel RMS, ELIM, and Arwa No Connection deployments.
After obtaining a work order for a new license with higher capacity:
- If required, contact your Ericsson supplier and order a new license key file with the required changes.
- Install the new license key file.
For more information on installing a license key file, refer to "Installing License Key Files" in the user guide for your LM deployment.
- Note:
- For Arwa No Connection, refer to the ELIM documentation.
- After installing the license key file, use ssh to connect
to the COM CLI Management System server port (default 22) on the blade
where the active COM CLI is running:
ssh <username>@<blade_IP_address> -p 22 -t -s cli
The COM CLI opens after supplying your password.
- Check the alarm status.
- If the alarm is still active, trigger an additional refresh
of the license inventory to ensure that the license changes are applied:
ManagedElement=1, SystemFunctions=1, Lm=1, refreshLicenseInventory
The system returns true if the action was executed successfully.
- Verify that the license inventory has been synchronized
with the new license key file by checking the lastLicenseInventoryRefresh timestamp:
show ManagedElement=1, SystemFunctions=1, Lm=1, lastLicenseInventoryRefresh
A recent timestamp indicates a successful update.
- Check the alarm status.
If the alarm is still active, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
2.4 Actions to Obtain New License Keys for Arwa
- Note:
- This procedure is not applicable to LM deployments using Arwa No Connection. When deployed in Arwa No Connection mode, LM uses ELIM formatted license key files to store license information locally. For more information on ordering and installing a new license key file, refer to Section 2.3.
After obtaining a work order for a new license with higher capacity:
- If required, contact your Ericsson supplier to order an entitlement containing the necessary licenses.
- After the new license keys have been provisioned in Arwa,
use ssh to connect to the COM CLI Management System server port (default
22) on the blade where the active COM CLI is running:
ssh <username>@<blade_IP_address> -p 22 -t -s cli
The COM CLI opens after supplying your password.
- Check the alarm status.
- If the alarm is still active, trigger an additional refresh
of the license inventory to ensure that the license changes are applied:
ManagedElement=1, SystemFunctions=1, Lm=1, refreshLicenseInventory
The system returns true if the action was executed successfully.
- Verify that the license inventory has been synchronized
with Arwa by checking the lastLicenseInventoryRefresh timestamp:
show ManagedElement=1, SystemFunctions=1, Lm=1, lastLicenseInventoryRefresh
A recent timestamp indicates a successful update.
- Check the alarm status.
If the alarm is still active, consult the next level of maintenance support. Further actions are outside the scope of this instruction.