1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is a primary alarm. The alarm is issued by a service of the Core Middleware (Core MW) component, which is not modeled as a Managed Object (MO).
The alarm is issued when the AMF cannot successfully instantiate a software component.
Depending on the software component, a successful instantiation can, for example, encompass the following:
- A successful start of processes
- A successful creation of files
- A successful execution of commands
A software component instantiation can fail, either when encountering an error situation, or when it is unable to complete successfully within a specified time, and all subsequent attempts to revive the component did not resolve the issue.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Software failure in the reported component. |
The component AMF tries to instantiate does not acknowledge its successful instantiation in time. |
The component is defect. |
The component that fails to be instantiated. |
The service the component provides is lost. |
|
The High Availability (HA) configuration for the component is not correct. |
The AMF configuration of the component is not correct, for example, defines an incorrect instantiation command or too short time for instantiation. |
The AMF configuration for the component is defect. |
The configuration of the component that fails to be instantiated. |
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
18568 |
|
Minor Type |
131074 |
|
Source(1) |
safApp=<*>,safSg=<*>,safSu=<*>,safComp=<*> |
|
Specific Problem |
|
|
Event Type |
processingErrorAlarm (4) |
|
Probable Cause |
x736UnspecifiedReason (418) |
|
Additional Text |
Instantiation of Component <LDAP DN of component> failed |
|
Perceived Severity |
major (4) |
(1) As sent by Core MW in NTF alarm notification.
It is changed when converted to FM model alarm.
- Note:
- The alarm can appear as a result of initial installation or software upgrade.
1.2 Prerequisites
Before starting this procedure, ensure that the following documents have been read:
- System Safety Information
- Personal Health and Safety Information
- COM Management Guide
2 Procedure
This section describes the procedure to follow when this alarm is received.
2.1 Actions for All Causes
To cease the alarm:
- Consult the next level of maintenance support for an analysis of the root cause to the component instantiation failure.
- When the cause has been identified and relevant corrective
measures have been taken, cease the alarm:
cmw-alarm-clear instantiation <Managed Object>
Here <Managed Object> is the DN of alarming object and given by the field source in the alarm.
- Restart the software correctly:
cmw-node-reboot <hostname>
Here <hostname> is the hostname of the computer hosting the component for which instantiation failed.
- Confirm that the alarm does not reappear.
If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.