CUDB Node Fault Management Configuration Guide

Contents

1Introduction
1.1Document Purpose and Scope
1.2Revision Information
1.3Typographic Conventions

2

Alarms in the CUDB System
2.1Application Alarms
2.1.1Alarm Format and Description
2.1.2Alarm Management
2.1.3Alarm List
2.1.4Alarm Relationships
2.2Infrastructure Alarms

3

Configuration

Glossary

Reference List

1   Introduction

This document provides Fault Management (FM) information for the Ericsson Centralized User Database (CUDB).

1.1   Document Purpose and Scope

The purpose of this document is to provide a list of application alarms, and describe the alarm management and the application alarm model of the CUDB system. The infrastructure alarms of the system are not in the scope of this document, but are shortly summarized in Section 2.2.

1.2   Revision Information

Rev. A This document is based on 3/1553-CSH 109 067/9 with the following changes:
  • Updated hardware information.
  • Terminology updates throughout the document because of virtualized deployment support.
  • Section 2.1.3.10: Updated Figure 12 with licensing information and Table 11 with alarm raised by licensing problems.
Rev. B Editorial changes only.

1.3   Typographic Conventions

Typographic conventions can be found in the following document:

2   Alarms in the CUDB System

An alarm in the CUDB system is a message sent through the CUDB SNMP interface that informs the operator about a problem in the node which requires attention. The CUDB system can raise two types of alarms:

For more information on the management and alarm model of the application alarms, see Section 2.1. For a brief summary of the management of infrastructure alarms, see Section 2.2.

2.1   Application Alarms

This section describes the management and alarm model of the CUDB application alarms.

CUDB application components (including the software component, that is the operating system and Core Middleware) send their alarms through ESA. The alarms sent to ESA are formatted according to the ERICSSON-SNF-ALARM-MIB and are sent to the Network Management System (NMS). For more information, refer to ESA Fault Management, Reference [90].

2.1.1   Alarm Format and Description

An alarm model is a logical description of the CUDB system described in a tree structure. The alarm model in Figure 1 illustrates the hierarchy of the CUDB application components which are able to raise alarms.

Figure 1   CUDB Alarms Model Overview

The alarm format used by the CUDB application components is defined by the ERICSSON-SNF-ALARM-MIB. For more information, refer to ESA Fault Management, Reference [90]. The standard location for this file, as well as for other mib files used by the CUDB FM interface, is defined by Ericsson SNMP Agent (ESA) in ESA Setup and Configuration, Reference [91].

Table 1 provides relevant information about the alarms. The Severity, Alarm Event Type and Probable Cause values follow the X.733 International Telecommunications Union (ITU) recommendation, refer to Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733. CCITT Rec. X.733 (1992 E)Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733, Reference [92].

Table 1    Alarm-Related Information

Attribute Name

Attribute Value

Auto Cease

No if the alarm is not auto ceased; Yes otherwise.

Module

The CUDB application component that raises the alarm. See Figure 1 under cudb(169).

Error Code

Assigned number identifying the alarm within a certain module (application component).

Timestamp First

Date and time when the alarm was raised for the first time.

Repeated Counter

Number which indicates how many times the alarm was raised.

Timestamp Last

Date and time of the most recent alarm raise.

Resource ID

An identifier of the alarming resource. The Object Identifier (OID) derived from the alarm model is used as the base for this identifier.

Alarm Model Description

A short description of the event.

Alarm Active Description

A dynamic text with a detailed description of the event.

ITU Alarm Event Type

A text that describes the type of the selected event, for example Communications Alarm, Processing Error Alarm or Operational Violation


For more information, refer to Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733. CCITT Rec. X.733 (1992 E)Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733, Reference [92].

ITU Alarm Probable Cause

A text that describes the probable cause of the event.


For more information, refer to Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733. CCITT Rec. X.733 (1992 E)Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733, Reference [92].

ITU Alarm Perceived Severity

The status of the event. One of the following:


(1) - Cleared


(2) - Indeterminate


(3) - Critical


(4) - Major


(5) - Minor


(6) - Warning


For more information refer to Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733. CCITT Rec. X.733 (1992 E)Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733, Reference [92].

Originating Source IP

Node IP where the alarm was raised.

Sequence Number

Number which indicates the order in which alarms are raised.

2.1.2   Alarm Management

The CUDB application does not provide specific management procedures for the mentioned alarms apart from the manual alarm clearing procedure provided by ESA, as described in Section 2.1.2.1.

2.1.2.1   Clearing Alarms

To clear an alarm, use the fmsendmessage command with the clear parameter:

# fmsendmessage -c <module> <errorcode> <resourceid> [<Alarm Active Description>] <originatingsourceip>

where:

Example 1   Clearing an Alarm

To clear the following non-autocease alarm:

---------------------------------------------------------------
Module                       : STORAGE-ENGINE
Error Code                   : 8
Resource ID                  : .1.3.6.1.4.1.193.169.1.2.8.100
Timestamp First              : Thu Sep 24 13:41:48 CEST 2015
Repeated Counter             : 1
Timestamp Last               : Thu Sep 24 13:41:48 CEST 2015
Alarm Model Description      : Memory usage at Warning level, Storage Engine.
Alarm Active Description     : Storage Engine (DS-group #100): memory usage at Warning level.
ITU Alarm Event Type         : 4
ITU Alarm Probable Cause     : 151
ITU Alarm Perceived Severity : warning
Originating source IP        : 10.143.56.132
Sequence Number              : 554
---------------------------------------------------------------

this command is used:

# fmsendmessage -c STORAGE-ENGINE 8 .1.3.6.1.4.1.193.169.1.2.8.100 "Manually cleared by User" 10.143.56.132
Warning!

Even though the help message of fmsendmessage suggests that the <sourceIP> parameter is optional, this is not the case in CUDB. If the parameter is not specified, the default value (IP address of the blade or Virtual Machine (VM) on which the command is executed) is used and the existing alarm is not cleared.

For instance, if the fmsendmessage -c STORAGE-ENGINE 8 .1.3.6.1.4.1.193.169.1.2.8.100 command is executed (where the <sourceIP> parameter is missing), the alarm shown in Example 1 is not cleared.

2.1.3   Alarm List

Alarms are grouped by different application components, as shown in Figure 1. They are described in detail in the following subsection. The alarms in the tables are in alphabetical order.

2.1.3.1   Storage Engine

Storage Engine alarms are related to the Database Cluster. The alarm model for PLDB alarms is shown in Figure 2.

Figure 2   Alarm Model for PLDB Storage Engine Alarms

The alarm model for DS and general alarms is shown in Figure 3.

Figure 3   Alarm Model for DS and General Storage Engine Alarms

Table 2 shows the list of alarms related to Storage Engine.

Table 2    Alarms Raised by Storage Engine Problems

Alarm

Operating Instruction

Storage Engine, Automatic Handling of Network Isolation not Completed for DS

Refer to Storage Engine, Automatic Handling of Network Isolation not Completed for DS, Reference [1].

Storage Engine, Automatic Handling of Network Isolation not Completed for PLDB

Refer to Storage Engine, Automatic Handling of Network Isolation not Completed for PLDB, Reference [2].

Storage Engine, Backup Fault In DS

Refer to Storage Engine, Backup Fault In DS, Reference [3].

Storage Engine, Backup Fault In PLDB

Refer to Storage Engine, Backup Fault In PLDB, Reference [4].

Storage Engine, Backup Notification Failure To Provisioning Gateway

Refer to Storage Engine, Backup Notification Failure To Provisioning Gateway, Reference [5].

Storage Engine, Data Inconsistency between Replicas Found in DS, Major

Refer to Storage Engine, Data Inconsistency between Replicas Found in DS, Major, Reference [6].

Storage Engine, Data Inconsistency between Replicas Found in DS, Minor

Refer to Storage Engine, Data Inconsistency between Replicas Found in DS, Minor, Reference [7].

Storage Engine, Data Inconsistency between Replicas Found in PLDB, Major

Refer to Storage Engine, Data Inconsistency between Replicas Found in PLDB, Major, Reference [8].

Storage Engine, Data Inconsistency between Replicas Found in PLDB, Minor

Refer to Storage Engine, Data Inconsistency between Replicas Found in PLDB, Minor, Reference [9].

Storage Engine, Data Inconsistency between Replicas Repaired, DS

Refer to Storage Engine, Data Inconsistency between Replicas Repaired, DS, Reference [10].

Storage Engine, Data Inconsistency between Replicas Repaired, PLDB

Refer to Storage Engine, Data Inconsistency between Replicas Repaired, PLDB, Reference [11].

Storage Engine, Deleted Data Due to Reconciliation

Refer to Storage Engine, Deleted Data Due to Reconciliation, Reference [12].

Storage Engine, DS Cluster Down

Refer to Storage Engine, DS Cluster Down, Reference [13].

Storage Engine, DS Cluster in Maintenance Mode

Refer to Storage Engine, DS Cluster in Maintenance Mode, Reference [14].

Storage Engine, DS Cluster Node Down

Refer to Storage Engine, DS Cluster Node Down, Reference [15].

Storage Engine, Execution of Selective Replica Check Failed, DS, Major

Refer to Storage Engine, Execution of Selective Replica Check Failed, DS, Major, Reference [16].

Storage Engine, Execution of Selective Replica Check Failed, PLDB, Major

Refer to Storage Engine, Execution of Selective Replica Check Failed, PLDB, Major, Reference [17].

Storage Engine, High Load In DS

Refer to Storage Engine, High Load In DS, Reference [18].

Storage Engine, High Load In PLDB

Refer to Storage Engine, High Load In PLDB, Reference [19].

Storage Engine, Memory Usage Too High In DS, Full Threshold Reached

Refer to Storage Engine, Memory Usage Too High In DS, Full Threshold Reached, Reference [20].

Storage Engine, Memory Usage Too High In DS, Warning Threshold Reached

Refer to Storage Engine, Memory Usage Too High In DS, Warning Threshold Reached, Reference [21].

Storage Engine, Memory Usage Too High In PLDB, Major

Refer to Storage Engine, Memory Usage Too High In PLDB, Major, Reference [22].

Storage Engine, Memory Usage Too High In PLDB, Warning

Refer to Storage Engine, Memory Usage Too High In PLDB, Warning, Reference [23].

Storage Engine, No Available Master Replica for DS

Refer to Storage Engine, No Available Master Replica for DS, Reference [24].

Storage Engine, No Available Master Replica for PLDB

Refer to Storage Engine, No Available Master Replica for PLDB, Reference [25].

Storage Engine, Out Of Memory In DS

Refer to Storage Engine, Out Of Memory In DS, Reference [26].

Storage Engine, Out Of Memory In PLDB

Refer to Storage Engine, Out Of Memory In PLDB, Reference [27].

Storage Engine, Out Of Tablespace In DS

Refer to Storage Engine, Out Of Tablespace In DS, Reference [28].

Storage Engine, Out Of Tablespace In PLDB

Refer to Storage Engine, Out Of Tablespace In PLDB, Reference [29].

Storage Engine, PLDB Cluster Down

Refer to Storage Engine, PLDB Cluster Down, Reference [30].

Storage Engine, PLDB Cluster In Maintenance Mode

Refer to Storage Engine, PLDB Cluster In Maintenance Mode, Reference [31].

Storage Engine, PLDB Cluster Node Down

Refer to Storage Engine, PLDB Cluster Node Down, Reference [32].

Storage Engine, Potential Data Inconsistency between Replicas Found in DS

Refer to Storage Engine, Potential Data Inconsistency between Replicas Found in DS, Reference [33].

Storage Engine, Potential Data Inconsistency between Replicas Found in PLDB

Refer to Storage Engine, Potential Data Inconsistency between Replicas Found in PLDB, Reference [34].

Storage Engine, Replication Channels Down in DS

Refer to Storage Engine, Replication Channels Down in DS, Reference [35].

Storage Engine, Replication Channels Down in PLDB

Refer to Storage Engine, Replication Channels Down in PLDB, Reference [36].

Storage Engine, Replication Delay Too High In DS

Refer to Storage Engine, Replication Delay Too High In DS, Reference [37].

Storage Engine, Replication Delay Too High In PLDB

Refer to Storage Engine, Replication Delay Too High In PLDB, Reference [38].

Storage Engine, Replication Stopped Working in DS

Refer to Storage Engine, Replication Stopped Working in DS, Reference [39].

Storage Engine, Replication Stopped Working in PLDB

Refer to Storage Engine, Replication Stopped Working in PLDB, Reference [40].

Storage Engine, Restore Fault in DS

Refer to Storage Engine, Restore Fault in DS, Reference [41].

Storage Engine, Restore Fault in PLDB

Refer to Storage Engine, Restore Fault in PLDB, Reference [42].

Storage Engine, Tablespace Usage Too High In DS, Warning

Refer to Storage Engine, Tablespace Usage Too High In DS, Warning, Reference [43].

Storage Engine, Tablespace Usage Too High In PLDB, Warning

Refer to Storage Engine, Tablespace Usage Too High In PLDB, Warning, Reference [44].

Storage Engine, Temporary Data Inconsistency

Refer to Storage Engine, Temporary Data Inconsistency, Reference [45].

Storage Engine, Unable to Synchronize Cluster in DS, Major

Refer to Storage Engine, Unable to Synchronize Cluster in DS, Major, Reference [46].

Storage Engine, Unable to Synchronize Cluster in DS, Warning

Refer to Storage Engine, Unable to Synchronize Cluster in DS, Warning, Reference [47].

Storage Engine, Unable to Synchronize Cluster in PLDB, Major

Refer to Storage Engine, Unable to Synchronize Cluster in PLDB, Major, Reference [48].

Storage Engine, Unable to Synchronize Cluster in PLDB, Warning

Refer to Storage Engine, Unable to Synchronize Cluster in PLDB, Warning, Reference [49].

Storage Engine, Unrepaired Data Inconsistency between Replicas, PLDB

Refer to Storage Engine, Unrepaired Data Inconsistency between Replicas, PLDB, Reference [50].

Storage Engine, Unrepaired Data Inconsistency between Replicas, DS

Refer to Storage Engine, Unrepaired Data Inconsistency between Replicas, DS, Reference [51].

2.1.3.2   Lightweight Directory Access Protocol Front End

The alarm model for Lightweight Directory Access Protocol (LDAP) Front End (FE)-related alarms is shown in Figure 4.

Figure 4   Alarm Model for LDAP Alarms

Table 3 shows the list of alarms related to LDAP FE.

Table 3    Alarms Raised by LDAP FE Problems

Alarm

Operating Instruction

LDAP Front End, High Load in LDAP Processing Layer

Refer to LDAP Front End, High Load in LDAP Processing Layer, Reference [53]

LDAP Front End, Processing Capacity Below Minimum

Refer to LDAP Front End, Processing Capacity Below Minimum, Reference [54]

LDAP Front End, Processing Redundancy Lost

Refer to LDAP Front End, Processing Redundancy Lost, Reference [55]

LDAP Front End, Server Down

Refer to LDAP Front End, Server Down, Reference [56]

2.1.3.3   Server Platform

The alarm model for Server Platform-related alarms is shown in Figure 5.

Figure 5   Alarm Model for Server Platform Alarms

Table 4 shows the list of alarms related to Server Platform.

Table 4    Alarms Raised by Server Platform Problems

Alarm

Operating Instruction

Server Platform, Storage Performance Degradation Detected

Refer to Server Platform, Storage Performance Degradation Detected, Reference [52]

2.1.3.4   Operating System

The alarm model for Operating System-related alarms is shown in Figure 6.

Figure 6   Alarm Model for Operating System Alarms

Table 5 shows the list of alarms related to the Operating System.

Table 5    Alarms Raised by Operating System Problems

Alarm

Operating Instruction

Operating System, Disk Usage Too High

Refer to Operating System, Disk Usage Too High, Reference [57]

Operating System, Server Configuration Backup Fault

Refer to Operating System, Server Configuration Backup Fault, Reference [58]

2.1.3.5   Control

The alarm model for node visibility and global system status related alarms is shown in Figure 7.

Figure 7   Alarm Model for Control Alarms

Table 6 shows the list of alarms related to Control.

Table 6    Alarm Raised by Control Problems

Alarm

Operating Instruction

Control, Automatic Master Election Locked Down

Refer to Control, Automatic Master Election Locked Down, Reference [59]

Control, Blackboard Coordination Cluster Down

Refer to Control, Blackboard Coordination Cluster Down, Reference [60]

Control, Blackboard Coordination Server Down

Refer to Control, Blackboard Coordination Server Down, Reference [61]

Control, Potential Split Brain Detected

Refer to Control, Potential Split Brain Detected, Reference [62]

Control, Remote Node Unreachable

Refer to Control, Remote Node Unreachable, Reference [63]

Control, Remote Site Unreachable

Refer to Control, Remote Site Unreachable, Reference [64]

2.1.3.6   Application Counters

The alarm model for Application Counters-related alarms is shown in Figure 8.

Figure 8   Alarm Model for Application Counters Alarms

Table 7 shows the list of alarms related to Application Counters.

Table 7    Alarm Raised by Application Counters Problems

Alarm

Operating Instruction

Application Counters, Fault In Subscriber Statistic Application

Refer to Application Counters, Fault In Subscriber Statistic Application, Reference [65]

2.1.3.7   Service Availability Forum

The alarm model for Service Availability Forum (SAF)-related alarms is shown in Figure 9.

Figure 9   Alarm Model for SAF Alarms

Table 8 shows the list of alarms related to SAF.

Table 8    Alarms Raised by SAF Problems

Alarm

Operating Instruction

SAF, AMF Component Cleanup Failed

Refer to SAF, AMF Component Cleanup Failed, Reference [66]

SAF, AMF Component Instantiation Failed

Refer to SAF, AMF Component Instantiation Failed, Reference [67]

SAF, AMF SI Unassigned

Refer to SAF, AMF SI Unassigned, Reference [68]

SAF, CLM Cluster Node Unavailable

Refer to SAF, CLM Cluster Node Unavailable, Reference [69]

SAF, LOTC Disk Replication Communication Failed

Refer to SAF, LOTC Disk Replication Communication Failed, Reference [70]

SAF, LOTC Disk Replication Consistency Failed

Refer to SAF, LOTC Disk Replication Consistency Failed, Reference [71]

SAF, LOTC Ethernet Bonding Failed

Refer to SAF, LOTC Ethernet Bonding Failed, Reference [72]

SAF, LOTC Memory Usage Failed

Refer to SAF, LOTC Memory Usage Failed, Reference [73]

SAF, LOTC Time Synchronization Failed

Refer to SAF, LOTC Time Synchronization Failed, Reference [74]

2.1.3.8   Security

The alarm model for Security-related alarms is shown in Figure 10.

Figure 10   Alarm Model for Security Alarms

Table 9 shows the list of alarms related to Security.

Table 9    Alarms Raised by Security Problems

Alarm

Operating Instruction

Security, OAM User Exceeded Number Of Failed Logins

Refer to Security, OAM User Exceeded Number Of Failed Logins, Reference [75]

Security, OAM User Gaining Privilege Failed

Refer to Security, OAM User Gaining Privilege Failed, Reference [76]

Security, OAM User Privilege Raise To Root Failed

Refer to Security, OAM User Privilege Raise To Root Failed, Reference [77]

Security, Root Login Failed

Refer to Security, Root Login Failed, Reference [78]

2.1.3.9   Preventive Maintenance

The alarm model for Preventive Maintenance underlaying related alarms is shown in Figure 11.

Figure 11   Alarm Model for Preventive Maintenance

Table 10 shows the list of alarms related to Preventive Maintenance.

Table 10    Alarm Raised by Preventive Maintenance Problems

Alarm

Operating Instruction

Preventive Maintenance, Logchecker Found Error(s)

Refer to Preventive Maintenance, Logchecker Found Error(s), Reference [79].

2.1.3.10   Licensing

The alarm model for Licensing - related alarms is shown in Figure 12.

Figure 12   Alarm Model for Licensing Alarms

Table 11 shows the list of alarms related to Licensing.

Table 11    Alarms Raised by Licensing Problems

Alarm

Operating Instruction

Licensing, Autonomous Mode Activated

Refer to Licensing, Autonomous Mode Activated, Reference [80].

Licensing, Capacity Usage Threshold Reached, Major

Refer to Licensing, Capacity Usage Threshold Reached, Major, Reference [81].

Licensing, Capacity Usage Threshold Reached, Warning

Refer to Licensing, Capacity Usage Threshold Reached, Warning, Reference [82].

Licensing, Emergency Unlock Reset Key Required

Refer to Licensing, Emergency Unlock Reset Key Required, Reference [83].

Licensing, Key File Fault

Refer to Licensing, Key File Fault, Reference [84].

Licensing, License Key Not Available, Major

Refer to Licensing, License Key Not Available, Major, Reference [85].

Licensing, License Key Not Available, Minor

Refer to Licensing, License Key Not Available, Minor, Reference [86].

Licensing, License Manager Not Available

Refer to Licensing, License Manager Not Available, Reference [87].

2.1.4   Alarm Relationships

The following alarm relationships are present in the system:

2.2   Infrastructure Alarms

Consider the following regarding infrastructure alarms:

3   Configuration

Some of the alarms are raised when the value of a parameter in CUDB goes above a configured threshold. See the specific alarm OPIs for information on the applicable parameters and thresholds, and how to configure them. It is also possible to configure the NMS IP address where alarm traps are sent. The version used for SNMP is version 3.

For more details about how to configure SNMP for CUDB application components, refer to ESA Fault Management, Reference [91]. For more information on configuring SNMP for infrastructure components, see Section 2.2.

Note:  
In CUDB ESA configuration, the Master Agent Main Port is 60.


Glossary

For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [89].


Reference List

CUDB Documents
[1] Storage Engine, Automatic Handling of Network Isolation not Completed for DS.
[2] Storage Engine, Automatic Handling of Network Isolation not Completed for PLDB.
[3] Storage Engine, Backup Fault In DS.
[4] Storage Engine, Backup Fault In PLDB.
[5] Storage Engine, Backup Notification Failure To Provisioning Gateway.
[6] Storage Engine, Data Inconsistency between Replicas Found in DS, Major.
[7] Storage Engine, Data Inconsistency between Replicas Found in DS, Minor.
[8] Storage Engine, Data Inconsistency between Replicas Found in PLDB, Major.
[9] Storage Engine, Data Inconsistency between Replicas Found in PLDB, Minor.
[10] Storage Engine, Data Inconsistency between Replicas Repaired, DS.
[11] Storage Engine, Data Inconsistency between Replicas Repaired, PLDB.
[12] Storage Engine, Deleted Data Due to Reconciliation.
[13] Storage Engine, DS Cluster Down.
[14] Storage Engine, DS Cluster in Maintenance Mode.
[15] Storage Engine, DS Cluster Node Down.
[16] Storage Engine, Execution of Selective Replica Check Failed, DS, Major.
[17] Storage Engine, Execution of Selective Replica Check Failed, PLDB, Major.
[18] Storage Engine, High Load In DS.
[19] Storage Engine, High Load In PLDB.
[20] Storage Engine, Memory Usage Too High In DS, Full Threshold Reached.
[21] Storage Engine, Memory Usage Too High In DS, Warning Threshold Reached.
[22] Storage Engine, Memory Usage Too High In PLDB, Major.
[23] Storage Engine, Memory Usage Too High In PLDB, Warning.
[24] Storage Engine, No Available Master Replica for DS.
[25] Storage Engine, No Available Master Replica for PLDB.
[26] Storage Engine, Out Of Memory In DS.
[27] Storage Engine, Out Of Memory In PLDB.
[28] Storage Engine, Out Of Tablespace In DS.
[29] Storage Engine, Out Of Tablespace In PLDB.
[30] Storage Engine, PLDB Cluster Down.
[31] Storage Engine, PLDB Cluster In Maintenance Mode.
[32] Storage Engine, PLDB Cluster Node Down.
[33] Storage Engine, Potential Data Inconsistency between Replicas Found in DS.
[34] Storage Engine, Potential Data Inconsistency between Replicas Found in PLDB.
[35] Storage Engine, Replication Channels Down in DS.
[36] Storage Engine, Replication Channels Down in PLDB.
[37] Storage Engine, Replication Delay Too High In DS.
[38] Storage Engine, Replication Delay Too High In PLDB.
[39] Storage Engine, Replication Stopped Working in DS.
[40] Storage Engine, Replication Stopped Working in PLDB.
[41] Storage Engine, Restore Fault in DS.
[42] Storage Engine, Restore Fault in PLDB.
[43] Storage Engine, Tablespace Usage Too High In DS, Warning.
[44] Storage Engine, Tablespace Usage Too High In PLDB, Warning.
[45] Storage Engine, Temporary Data Inconsistency.
[46] Storage Engine, Unable to Synchronize Cluster in DS, Major.
[47] Storage Engine, Unable to Synchronize Cluster in DS, Warning.
[48] Storage Engine, Unable to Synchronize Cluster in PLDB, Major.
[49] Storage Engine, Unable to Synchronize Cluster in PLDB, Warning.
[50] Storage Engine, Unrepaired Data Inconsistency between Replicas, PLDB.
[51] Storage Engine, Unrepaired Data Inconsistency between Replicas, DS.
[52] Server Platform, Storage Performance Degradation Detected.
[53] LDAP Front End, High Load in LDAP Processing Layer.
[54] LDAP Front End, Processing Capacity Below Minimum.
[55] LDAP Front End, Processing Redundancy Lost.
[56] LDAP Front End, Server Down.
[57] Operating System, Disk Usage Too High.
[58] Operating System, Server Configuration Backup Fault.
[59] Control, Automatic Master Election Locked Down.
[60] Control, Blackboard Coordination Cluster Down.
[61] Control, Blackboard Coordination Server Down.
[62] Control, Potential Split Brain Detected.
[63] Control, Remote Node Unreachable.
[64] Control, Remote Site Unreachable.
[65] Application Counters, Fault In Subscriber Statistic Application.
[66] SAF, AMF Component Cleanup Failed.
[67] SAF, AMF Component Instantiation Failed.
[68] SAF, AMF SI Unassigned.
[69] SAF, CLM Cluster Node Unavailable.
[70] SAF, LOTC Disk Replication Communication Failed.
[71] SAF, LOTC Disk Replication Consistency Failed.
[72] SAF, LOTC Ethernet Bonding Failed.
[73] SAF, LOTC Memory Usage Failed.
[74] SAF, LOTC Time Synchronization Failed.
[75] Security, OAM User Exceeded Number Of Failed Logins.
[76] Security, OAM User Gaining Privilege Failed.
[77] Security, OAM User Privilege Raise To Root Failed.
[78] Security, Root Login Failed.
[79] Preventive Maintenance, Logchecker Found Error(s).
[80] Licensing, Autonomous Mode Activated.
[81] Licensing, Capacity Usage Threshold Reached, Major.
[82] Licensing, Capacity Usage Threshold Reached, Warning.
[83] Licensing, Emergency Unlock Reset Key Required.
[84] Licensing, Key File Fault.
[85] Licensing, License Key Not Available, Major.
[86] Licensing, License Key Not Available, Minor.
[87] Licensing, License Manager Not Available.
[88] CUDB Consistency Check.
[89] CUDB Glossary of Terms and Acronyms.
Other Ericsson Documents
[90] ESA Fault Management.
[91] ESA Setup and Configuration.
Other Documents and Online References
[92] Information Technology - Open Systems Interconnection - Systems Management Alarm Reporting Function ITU-T X.733. CCITT Rec. X.733 (1992 E) http://www.itu.int/rec/T-REC-X.733/.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    CUDB Node Fault Management Configuration Guide