1 Introduction
This instruction concerns alarm handling for the SAF, AMF SI Unassigned alarm.
1.1 Alarm Description
This alarm is associated with the Service Availability Forum (SAF). Refer toCUDB Node Fault Management Configuration Guide, Reference [1] for more information.
For information on the possible alarm causes and the corresponding fault reasons, fault locations, and impacts, refer to COM SA, AMF SI Unassigned, Reference [2].
The alarm attributes are listed and explained in Table 1.
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
Yes |
|
Module |
SAF |
|
Error Code |
2 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raise. |
|
Resource ID |
.1.3.6.1.4.1.193.169.9.2. .<length>.<NOI> |
|
Alarm Model Description |
AMF SI Unassigned, SAF |
|
Alarm Active Description |
SAF platform: AMF SI Unassigned @<NON> |
|
ITU Alarm Event Type |
other (1) |
|
ITU Alarm Probable Cause |
softwareProgramError (546) |
|
ITU Alarm Perceived Severity |
(4) – Major |
|
Originating source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which the alarms are raised. |
For further information about attribute descriptions refer to CUDB Node Fault Management Configuration Guide, Reference [1].
In Table 1, the indicated variables are as follows:
- <NON> is the
notifying object name that indicates where the component that generates
the alarm is. For example:
ManagedElement=1,SaAmfApplication.safApp=ERIC-CUDB_CUDBOI,SaAmfSI.safSi=2N-1
- <NOI> is the
notifying object identifier. It corresponds to <NON> in a dot-separated, ASCII-decimal-encoded, character-per-character
format. For example:
77.97.110.97.103.101.100.69.108.101.109.101.110.116.61.49.44.83.97.65.109.102.65.112.112.108.105.99.97.116.105.111.110.46.115.97.102.65.112.112.61.69.82.73.67.45.67.85.68.66.95.67.85.68.66.79.73.44.83.97.65.109.102.83.73.46.115.97.102.83.105.61.50.78.45.49 for ManagedElement=1,SaAmfApplication.safApp=ERIC-CUDB_CUDBOI,SaAmfSI.safSi=2N-1.
- <length> is the number of characters in <NON>, which is equivalent to the number of octets in <NOI>. In the previous example, <length> is 76.
The alarm can be cleared following the instructions specified in COM SA, AMF SI Unassigned, Reference [2].
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
- CUDB Node Fault Management Configuration Guide, Reference [1], regarding alarm configuration.
- System Safety Information, Reference [3]
- Personal Health and Safety Information, Reference [4]
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
Do the following:
- Follow the instructions specified in COM SA, AMF SI Unassigned, Reference [2], and refer to Core MW Management Guide, Reference [5] for more information on the proposed troubleshooting commands. The alarm must cease.
- If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.