Change Alarm Type Severity

Contents

1Introduction
1.1Prerequisites

2

Procedure

1   Introduction

This document describes how to change the alarm type severity. The user can experience that the designed alarm severity does not match the actual perceived severity in the network solution and can change its value.

1.1   Prerequisites

This section describes the prerequisites, which must be fulfilled before using the procedure.

1.1.1   Conditions

The following conditions must apply:

2   Procedure

To change the alarm type severity:

  1. Navigate to the FmAlarmType managed object, for example:

    >dn ManagedElement=NODE06ST,SystemFunctions=1,Fm=1,FmAlarmModel=SwM,FmAlarmType=FallbackOperationStartingSoon

  2. Show the alarm severity:

    (FmAlarmType=FallbackOperationStartingSoon)>show defaultSeverity

    defaultSeverity=[]
  3. Enter Config mode:

    (FmAlarmType=FallbackOperationStartingSoon)>configure

  4. Change the alarm type severity, for example:

    (config-FmAlarmType=FallbackOperationStartingSoon)>configuredSeverity=MINOR

  5. Commit the change:

    (config-FmAlarmType=FallbackOperationStartingSoon)>commit

  6. Verify the change:

    (FmAlarmType=FallbackOperationStartingSoon)>show configuredSeverity

    configuredSeverity=MINOR