1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The SAPC raises this alarm when there is no connectivity to the:
- SMS center destination.
- web service end point destination.
The SAPC clears the alarm when it successfully:
- Sends a bind request to the SMS center destination.
- Delivers a SOAP Notification to the web service end point destination.
The possible causes of this alarm are:
- The SAPC does not have connectivity to the SMS center destination.
- The web service end point destination does not answer a SOAP request.
As a result of the fault, the SAPC can not send:
- SMS notifications messages to the SMS center destination
- SOAP requests to the web service end point destination.
1.1.1 Alarm Attributes
The main attributes of the alarm are the following:
|
Attribute Name |
Attribute Value |
|---|---|
|
Alarm Type Id |
ConnectionNotificationServerFailed |
|
Major Type |
193 |
|
Minor Type |
7077893 |
|
Specific Problem |
Policy Control, Connection to Notification Server Failed. |
|
Severity |
Minor |
|
Source |
ManagedElement=1,PolicyControlFunction=1,Network=1,SmsCenter=1,SmsCenterDestination=<serverAddress> ManagedElement=1,PolicyControlFunction=1,Network=1,WebServiceEndPoints=1,WebServiceEndPoint=<webServiceEndPoint>,WebServiceEndPointDestination=<webServiceUrl> Example: ManagedElement=1,PolicyControlFunction=1,Network=1,SmsCenter=1,SmsCenterDestination=1.2.3.4 |
|
Probable Cause |
100505 |
|
Event Type |
Communications |
|
Additional Text |
Connection to Notification Server Failed |
|
Last Event Time |
YYYY-MM-DDTHH:mm:ss<time zone> |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions needed before performing steps to cease the alarm.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
- For information about the notifications configuration, refer to Configuration Guide for End User Notifications.
- For information about Fault Management, refer to Fault Management.
1.2.2 Tools
No specific tools are required.
1.2.3 Conditions
No conditions.
2 Procedure
Do the following:
- Check that the notification server (source field in Table 1) is up and running and is accepting connections.
- Check the TCP/IP connectivity between the SAPC and the notification server.
- Check the configuration objects related to the notification
server (source field in Table 1) in the SAPC:
For SMS: SmsCenter, SmsDestination.
For SOAP: WebServiceEndPoint, WsDestination.
For more information on how to configure, refer to Configuration Guide for End User Notifications.
- If the alarm does not cease, consult next level of maintenance support. Further actions are outside the scope of this procedure.