Instances in

Management Information Base

Ss7CafAlarmModelSmNtfInstances



NtfMap=1
NameValue
baseDn
bindTimer10000
dnFormatDefault
majorId24209
ntfmapId1
ownDnSM_NTF_Agent=1
queueSize1000
tryagainCount10
tryagainTimer5000
vendorId193

    +-Notification=0
NameValue
alarmDocRefSS7 CAF OAM Connection Lost
classMinorId2304
eventTypeALARM_COMMUNICATION
moduleIdSAF_OAM
notificationId0
probableCauseUNSPECIFIED_REASON
severitySEVERITY_MAJOR

    +-Notification=1
NameValue
alarmDocRefSS7 CAF Process Down
classMinorId513
eventTypeALARM_COMMUNICATION
moduleIdECM
notificationId1
probableCauseCONFIGURATION_OR_CUSTOMIZATION_ERROR
severitySEVERITY_MAJOR

    +-Notification=111
NameValue
alarmDocRefSS7 CAF Route Set Failure
classMinorId1647
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId111
probableCauseREMOTE_NODE_TRANSMISSION_ERROR
severitySEVERITY_WARNING

    +-Notification=12
NameValue
alarmDocRefSS7 CAF SCTP IP Path is Down
classMinorId40204
eventTypeALARM_COMMUNICATION
moduleIdSCTP
notificationId12
probableCauseOUT_OF_SERVICE
severitySEVERITY_WARNING

    +-Notification=124
NameValue
alarmDocRefSS7 CAF SP State Change
classMinorId1660
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId124
probableCauseREMOTE_NODE_TRANSMISSION_ERROR
severitySEVERITY_MINOR

    +-Notification=126
NameValue
alarmDocRefSS7 CAF State Change
classMinorId1662
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId126
probableCauseREMOTE_NODE_TRANSMISSION_ERROR
severitySEVERITY_MINOR

    +-Notification=170
NameValue
alarmDocRefSS7 CAF Congestion Status Change
classMinorId1706
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId170
probableCauseCONGESTION
severitySEVERITY_WARNING

    +-Notification=2
NameValue
alarmDocRefSS7 CAF ECM Goes Down
classMinorId514
eventTypeALARM_COMMUNICATION
moduleIdECM
notificationId2
probableCauseUNSPECIFIED_REASON
severitySEVERITY_MINOR

    +-Notification=238
NameValue
alarmDocRefLicenseThresholdReached
classMinorId1774
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId238
probableCauseCONGESTION
severitySEVERITY_MINOR

    +-Notification=3
NameValue
alarmDocRefSS7 CAF Start Process Failed
classMinorId515
eventTypeALARM_COMMUNICATION
moduleIdECM
notificationId3
probableCauseCONFIGURATION_OR_CUSTOMIZATION_ERROR
severitySEVERITY_MAJOR

    +-Notification=30
NameValue
alarmDocRefSS7 CAF Local Link Congestion
classMinorId1566
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId30
probableCauseCONGESTION
severitySEVERITY_WARNING

    +-Notification=4
NameValue
alarmDocRefSS7 CAF Link out of service
classMinorId1540
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId4
probableCauseOUT_OF_SERVICE
severitySEVERITY_MAJOR

    +-Notification=40
NameValue
alarmDocRefSS7 CAF Dialogue Threshold High Watermark Exceeded ANSI TCAP
classMinorId2088
eventTypeALARM_COMMUNICATION
moduleIdANSITCAP
notificationId40
probableCauseTHRESHOLD_CROSSED
severitySEVERITY_WARNING

    +-Notification=42
NameValue
alarmDocRefSS7 CAF Remote SSN Status Change
classMinorId1322
eventTypeALARM_COMMUNICATION
moduleIdSCCP
notificationId42
probableCauseREMOTE_NODE_TRANSMISSION_ERROR
severitySEVERITY_WARNING

    +-Notification=43
NameValue
alarmDocRefSS7 CAF DPC State Change
classMinorId3115
eventTypeALARM_COMMUNICATION
moduleIdISUP
notificationId43
probableCauseCONGESTION
severitySEVERITY_MINOR

    +-Notification=44
NameValue
alarmDocRefSS7 CAF Resource Group State Change
classMinorId3116
eventTypeALARM_COMMUNICATION
moduleIdISUP
notificationId44
probableCauseOUT_OF_SERVICE
severitySEVERITY_MINOR

    +-Notification=46
NameValue
alarmDocRefSS7 CAF SCCP Bind Request
classMinorId1326
eventTypeALARM_COMMUNICATION
moduleIdSCCP
notificationId46
probableCauseUNSPECIFIED_REASON
severitySEVERITY_MINOR

    +-Notification=47
NameValue
alarmDocRefSS7 CAF SCCP Unbind Request
classMinorId1327
eventTypeALARM_COMMUNICATION
moduleIdSCCP
notificationId47
probableCauseUNSPECIFIED_REASON
severitySEVERITY_MINOR

    +-Notification=49
NameValue
alarmDocRefSS7 CAF Connections Exceed High Threshold
classMinorId1329
eventTypeALARM_COMMUNICATION
moduleIdSCCP
notificationId49
probableCauseTHRESHOLD_CROSSED
severitySEVERITY_WARNING

    +-Notification=5
NameValue
alarmDocRefSS7 CAF Remote Processor Outage
classMinorId1541
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId5
probableCauseOUT_OF_SERVICE
severitySEVERITY_WARNING

    +-Notification=58
NameValue
alarmDocRefSS7 CAF SSC Received
classMinorId1338
eventTypeALARM_COMMUNICATION
moduleIdSCCP
notificationId58
probableCauseCONGESTION
severitySEVERITY_WARNING

    +-Notification=6
NameValue
alarmDocRefSS7 CAF ECM Goes Active
classMinorId518
eventTypeALARM_COMMUNICATION
moduleIdECM
notificationId6
probableCauseUNSPECIFIED_REASON
severitySEVERITY_MINOR

    +-Notification=8
NameValue
alarmDocRefSS7 CAF Link Deactivated
classMinorId1544
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId8
probableCauseOUT_OF_SERVICE
severitySEVERITY_MINOR

    +-Notification=84
NameValue
alarmDocRefSS7 CAF Call Control Replaced
classMinorId3156
eventTypeALARM_COMMUNICATION
moduleIdISUP
notificationId84
probableCauseUNSPECIFIED_REASON
severitySEVERITY_MINOR

    +-Notification=88
NameValue
alarmDocRefSS7 CAF Number of Circuits Exceed High Water Mark
classMinorId3160
eventTypeALARM_COMMUNICATION
moduleIdISUP
notificationId88
probableCauseTHRESHOLD_CROSSED
severitySEVERITY_WARNING

    +-Notification=91
NameValue
alarmDocRefSS7 CAF Link Unavailable for UP
classMinorId1627
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId91
probableCauseOUT_OF_SERVICE
severitySEVERITY_WARNING

    +-Notification=93
NameValue
alarmDocRefSS7 CAF Dialogue Threshold High Watermark Exceeded
classMinorId1117
eventTypeALARM_COMMUNICATION
moduleIdTCAP
notificationId93
probableCauseTHRESHOLD_CROSSED
severitySEVERITY_WARNING

    +-Notification=94
NameValue
alarmDocRefSS7 CAF Low Link Availability
classMinorId1630
eventTypeALARM_COMMUNICATION
moduleIdMTPL3
notificationId94
probableCauseTHRESHOLD_CROSSED
severitySEVERITY_WARNING