Policy Control, EBM Communication Failure
Ericsson Service-Aware Policy Controller

Contents

1EBM Communication Failure Alarm Description

2

EBM Communication Failure Procedure
2.1Handle Alarm Policy Control, EBM Communication Failure

1   EBM Communication Failure Alarm Description

The SAPC raises this alarm in the following cases:

The SAPC clears this alarm in the following cases:

The main attributes of this alarm are the following:

Table 1    EBM Communication Failure Alarm Attributes

Attribute Name

Attribute Value

Alarm Type Id

EbmCommunicationFailure

Major Type

193

Minor Type

7077903

Specific Problem

Policy Control, EBM Communication Failure

Severity

Major

Source

ManagedElement=1,PolicyControlFunction=1,Network=1,EbmServers=1,EbmServer=<ip>:<port>


or


ManagedElement=1,PolicyControlFunction=1,Network=1,EbmServers=1(1)

Probable Cause

100505

Event Type

Communications

Additional Text

Failed to establish communication with the EBM Server. <No communication after three attempts | No EBM_VIP configured | No EBM Server configured>.

Last Event Time

YYYY-MM-DDTHH:mm:ss<time zone>

(1)   If no EBM server or EBM VIP address is configured.


2   EBM Communication Failure Procedure

2.1   Handle Alarm Policy Control, EBM Communication Failure

Prerequisites

Steps

  1. Check that the EBM server is functioning properly and is accepting connections.
  2. Check that the EBM server related data are properly configured in the SAPC. For further details, refer to Configuration Guide for Event-Based Monitoring.
  3. Check that the EBM VIP is configured properly. For further details, refer to Adapt Cluster Tool.
  4. If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this procedure.