eVIP, Configuration Fault

Contents

1Event Description

2

Handle eVIP, Configuration Fault

3

Configuration

4

Subscription

1   Event Description

The eVIP, Configuration Fault event is reported when Transport Management detects a faulty configuration. This occurs in the following situations:

Transport Management issues a stateless alarm (an event) when a faulty configuration is detected. All alarm listeners receive this event, even those who did not enter the faulty configuration, or are unaware that a reconfiguration attempt has occurred.

The configuration faults are divided into the following two types:

Table 1    eVIP, Configuration Fault Event Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

2129526884

Managed Object Class

<Managed Object (MO) where the fault was detected>

Managed Object Instance

<Distinguished Name of the MO where the fault was detected>

Event Type

communicationsAlarm (2)

Probable Cause

x736UnspecifiedReason (418)

Specific Problem

eVIP, Configuration Fault

Additional Text

Fault in eVIP Configuration

Perceived Severity

critical (3)

2   Handle eVIP, Configuration Fault

Steps

  1. Delete the MO where the fault was detected.
    Note:  
    This is only necessary if it was a semantic fault.

  2. Recreate the MO with correct configuration.
  3. Activate the MO (ALB or FEE) if necessary.
  4. Is the problem solved?
    Note:  
    If the problem is not solved, the alarm comes back when the MO is recreated.

    Yes: Proceed with Step 7.

    No: Continue with the next step.

  5. Perform data collection, refer to Data Collection Guideline.
  6. Consult the next level of maintenance support. Further actions are outside the scope of this document.
  7. Job is completed.

3   Configuration

Not Applicable.

4   Subscription

Not Applicable.