| 1 | Introduction |
| 1.1 | Target Groups |
| 1.2 | Typographic Conventions |
| 1.2.1 | Parameters |
2 | Configuration |
3 | Disk Partitioning |
Reference List | |
1 Introduction
This document describes the basic information on how to configure a virtualized Ericsson Dynamic Activation (EDA) system. By using this document readers are able to get necessary information about the parameters used in the installation.
1.1 Target Groups
The target groups for this document are as follows:
- Network Administrator
- System Administrators
- System Integrator
- Technicians who perform hardware installation and the first power on
Basic knowledge about Linux and general information about Dynamic Activation is needed for installation of the software.
1.2 Typographic Conventions
Typographic conventions are described in the document Library Overview, Reference [3].
For information about abbreviations used throughout this document refer to Glossary of Terms and Acronyms, Reference [1].
1.2.1 Parameters
The parameters in this document can be of the following types:
P - Predefined, not possible to change.
C - Customer configured after discussions with Ericsson.
D - Default, possible to change.
S - Site specific parameters. The site specific parameters can be identified in Customer Questionnaire for Virtual and Cloud Deployment, Reference [2].
2 Configuration
The following tables list parameters used when configuring Dynamic Activation in a virtualized deployment.
Table 1 contains cluster wide parameters, and Table 2 contains node specific parameters.
For more detailed information regarding network configuration, refer to Network Description and Configuration for Virtual and Cloud Deployment, Reference [4].
- Note:
- If IPv6 is used for one of the applicable parameters in the table below, all IPv6 parameters throughout this document become mandatory.
|
Parameter |
Description |
Type |
|---|---|---|
|
O&M VIPv4 |
Source and destination IP address for all GUI and SNMP traffic |
S, IP address |
|
O&M VIPv6 (Optional) |
S, IP address | |
|
Traffic VIPv4 |
Source and destination IP address for all provisioning traffic. |
S, IP address |
|
Traffic VIPv6 (Optionall) |
Source and destination IP address for all provisioning traffic. |
S, IP address |
|
Private VIPv4 |
Internal moveable IP address, used as NAT gateway address for real servers |
S, IP address |
|
Private VIPv6 (Optional) |
Internal moveable IP address, used as NAT gateway address for real servers |
S, IP address |
|
Domain Name |
The name of the domain that the nodes in the virtual cluster will belong to. For example epk.ericsson.se |
S, Domain name |
|
DNS Primary IP |
Address to primary DNS |
S, IP address |
|
DNS Secondary IP |
Address to secondary DNS |
S, IP address |
|
NTP Primary IP |
Address to primary NTP server |
S, IP address |
|
NTP Secondary IP |
Address to secondary NTP server |
S, IP address |
|
O&M Bridge |
The name of the bridge that enables access to the O&M network |
S, Bridge name |
|
Traffic Bridge |
The name of the bridge that enables access to the Traffic network |
S, Bridge name |
|
Private Bridge |
The name of the bridge that enables access to the Private network |
S, Bridge name |
|
O&M Gateway IPv4 |
Address to gateway for communicating with servers on the O&M network |
S, IP address |
|
O&M Gateway IPv6 (Optional) |
Address to gateway for communicating with servers on the O&M network |
S, IP address |
|
Traffic Gateway IPv4 |
Address to gateway for communicating with servers on the Traffic network |
S, IP address |
|
Traffic Gateway IPv6 (Optional) |
Address to gateway for communicating with servers on the Traffic network |
S, IP address |
|
O&M Netmask |
Netmask for the O&M network |
S, Netmask |
|
Traffic Netmask |
Netmask for the Traffic network |
S, Netmask |
|
Private Netmask |
Netmask for the Private network |
S, Netmask |
|
Virtual Router ID |
S, Virtual Router ID | |
|
OSS IP |
Address to the OSS towards which the cluster will send alarms |
S, IP address |
|
Parameter |
Description |
Type |
|---|---|---|
|
VM ID |
The name of the VM in the hypervisor |
S, VM name |
|
VM Host Name |
The hostname of the actual VM (not the host) |
S, Hostname |
|
#vCPUs |
The number of vCPUs that must be allocated to this VM |
S, #vCPUs |
|
Amount of RAM |
The amount of memory that must be allocated to this VM |
S, Amount of RAM |
|
O&M IPv4 |
The address of this VM that will use to communicate on the O&M network |
S, IP address |
|
O&M IPv6 (Optional) |
The address of this VM that will use to communicate on the O&M network |
S, IP address |
|
Traffic IPv4 |
The address of this VM that will use to communicate on the Traffic network |
S, IP address |
|
Traffic IPv6 (Optional) |
The address of this VM that will use to communicate on the Traffic network |
S, IP address |
|
Internal IPv4 |
The address of this VM that will use to communicate on the Private network |
S, IP address |
|
Internal IPv6 (Optional) |
The address of this VM that will use to communicate on the Private network |
S, IP address |
3 Disk Partitioning
The following table lists configurable parameters for disk partitioning.
For information about changing size of the partitions, see System Administrators Guide for Virtual and Cloud Deployment, Reference [5].
|
Label |
Device name |
Mount point |
Size |
Description |
Type |
|---|---|---|---|---|---|
|
CAS_DATA |
/dev/mapper/volgroup00-lv_casdata |
/var/cassandra/data |
Same as the size of the raw disk created and attached from the host system - 40GB |
Cassandra Data storage. |
P |
Reference List
| [1] Glossary of Terms and Acronyms, 0033-CSH 109 628 Uen |
| [2] Customer Questionnaire for Virtual and Cloud Deployment, 2/1057-CSH 109 628 Uen |
| [3] Library Overview, 18/1553-CSH 109 628 Uen |
| [4] Network Description and Configuration for Virtual and Cloud Deployment, 1/1551-CSH 109 628 Uen |
| [5] System Administrators Guide for Virtual and Cloud Deployment, 3/1543-CSH 109 628 Uen |

Contents