| 1 | Introduction |
| 1.1 | Target Groups |
| 1.2 | Typographic Conventions |
| 1.2.1 | Parameters |
2 | Configuration |
3 | Disk Partitioning |
Reference List | |
1 Introduction
This document describes the basic information on how to configure a Dynamic Activation system in a Cloud Execution Environment (CEE) deployment. By using this document readers are able to get necessary information about the parameters used in the installation.
1.1 Target Groups
The target groups for this document are as follows:
- Network Administrator
- System Administrators
- System Integrator
- Technicians who perform the VNF installation
Basic knowledge about Linux and general information about Dynamic Activation is needed for installation of the software.
1.2 Typographic Conventions
Typographic conventions are described in the document Library Overview, Reference [3].
For information about abbreviations used throughout this document refer to Glossary of Terms and Acronyms, Reference [1].
1.2.1 Parameters
The parameters in this document can be of the following types:
P - Predefined, not possible to change.
C - Customer configured after discussions with Ericsson.
D - Default, possible to change.
S - Site specific parameters. The site specific parameters can be identified in Customer Questionnaire for Virtual and Cloud Deployment, Reference [2].
2 Configuration
The following tables list parameters used when configuring Dynamic Activation in a CEE environment.
For more detailed information regarding network configuration, refer to Network Description and Configuration for Virtual and Cloud Deployment, Reference [4].
|
Parameter |
Description |
Type |
|---|---|---|
|
Management/provisioning network address |
The address for the network in which Dynamic Activation must expose its public addresses. Must be at least a size /28 network. |
S, IP Network |
|
Management network gateway |
The address to the gateway of the management network. This is often the first address in the network. |
S, IP Address |
|
Public Management DHCP net pool start |
Start of management network IP address allocation pool for dynamic allocation of Dynamic Activation external interfaces. Normally the first IP address is allocated to the vrrp gateway in the CMXes and the following two are the CMX-26 and CMX-28 IP addresses. |
S, IP Address |
|
Public Management DHCP net pool end |
End of management network IP address allocation pool for dynamic allocation of Dynamic Activation external interfaces. The last IP address is used for broadcast. |
S, IP Address |
|
VLAN ID (Customer Edge Router) |
The VLAN ID configured in the customer edge router for the management network. |
|
|
Internal Network Address |
The address for the internal network in which Dynamic Activation internal interfaces will reside. Must be at least a size /24 network. |
S, IP Network |
|
Instance host name prefix |
The prefix name that will be the first part of all host instance names. |
S, Name |
|
DNS Primary IP |
Address to primary DNS |
S, IP address |
|
Redundant DNS Server IP |
Address to secondary DNS |
S, IP address |
|
NTP Server IP |
Address to primary NTP server |
S, IP address |
|
Redundant NTP Server IP |
Address to secondary NTP server |
S, IP address |
|
Ephemeral size |
Size of the ephemeral disk that will be attached to each Dynamic Activation VM running Cassandra (node-1, node-2, node-3) |
S, Size in GB |
|
Time zone |
Time zone where the Dynamic Activation system will be located. |
S, Time Zone |
|
Virtual Router ID |
S, Virtual Router ID |
3 Disk Partitioning
The following table lists configurable parameters for disk partitioning.
For information about changing size of the partitions, see System Administrators Guide for Virtual and Cloud Deployment, Reference [5].
|
Label |
Device name |
Mount point |
Size |
Description |
Type |
|---|---|---|---|---|---|
|
CAS_DATA |
/dev/vdb2 |
/var/cassandra/data |
Ephemeral storage allocated to VM during deploy time –10 GB (CAS_COMLOG) |
Cassandra Data storage. |
P |
Reference List
| [1] Glossary of Terms and Acronyms, 0033-CSH 109 628 Uen |
| [2] Customer Questionnaire for Virtual and Cloud Deployment, 2/1057-CSH 109 628 Uen |
| [3] Library Overview, 18/1553-CSH 109 628 Uen |
| [4] Network Description and Configuration for Virtual and Cloud Deployment, 1/1551-CSH 109 628 Uen |
| [5] System Administrators Guide for Virtual and Cloud Deployment, 3/1543-CSH 109 628 Uen |

Contents