| 1 | Introduction |
| 1.1 | Target Groups |
| 1.2 | Typographic Conventions |
| 1.2.1 | Parameters |
2 | Configuration |
3 | Disk Partitioning |
Reference List | |
1 Introduction
This document describes the basic information on how to configure a Dynamic Activation system in an OpenStack deployment. By using this document readers are able to get necessary information about the parameters used in the installation.
1.1 Target Groups
The target groups for this document are as follows:
- Network Administrator
- System Administrators
- System Integrator
- Technicians who perform the VNF installation
Basic knowledge about Linux and general information about Dynamic Activation is needed for installation of the software.
1.2 Typographic Conventions
Typographic conventions are described in the document Library Overview, Reference [3].
For information about abbreviations used throughout this document refer to Glossary of Terms and Acronyms, Reference [1].
1.2.1 Parameters
The parameters in this document can be of the following types:
P - Predefined, not possible to change.
C - Customer configured after discussions with Ericsson.
D - Default, possible to change.
S - Site specific parameters. The site specific parameters can be identified in Customer Questionnaire for Virtual and Cloud Deployment, Reference [2].
2 Configuration
The following tables list parameters used when configuring Dynamic Activation in an OpenStack environment.
For more detailed information regarding network configuration, refer to Network Description and Configuration for Virtual and Cloud Deployment, Reference [4].
- Note:
- For Dynamic Activation deployed in OpenStack environment, only pure IPv4 is supported.
|
Parameter |
Description |
Type |
|---|---|---|
|
Stack Name |
Name of the infra stack to be created |
S, Name |
|
Name of Provider Network |
Name of the external/provider network |
S, Name |
|
Management/provisioning network address |
Internal network handling provisioning and O&M operations |
S, IP address |
|
Internal Network Address |
Internal network handling all internal communication between the instances |
S, IP Address |
|
Parameter |
Description |
Type |
|---|---|---|
|
Stack Name |
Name of the cluster stack to be created |
S, Name |
|
VM hostname prefix |
The prefix that will be used in the beginning of the host names of all EDA VM instances. A node number postfix will also be added to complete host names, -1, -2, -3, -4, and so on |
S, Name |
|
Name of provider Network |
Name of the external/provider network |
S, Name |
|
EDA cluster VRID |
Virtual router ID, must be unique when deploying several vEMA cluster in the same subnet. Value 0-255 |
S, Virtual Router ID |
|
Name of the vEDA image |
Image name for deploying EDA compute instance |
S, vEDA Name |
|
EDA VM flavor |
EDA flavor to be used for all instances in the cluster |
S, Flavor Name |
|
Availability Zone |
Choose in which Zone the EDA cluster will be deployed in |
S, Zone Name |
|
Volume Size |
Size of the blockstorage that will be created and attached to node-1, node-2 and node-3. Used by cassandra |
S, IP address |
|
Number of EDA instances in addition to the minimum 3 mandatory instances |
Additional EDA instances to be deployed. 1 will create 4 in total, 2 will create 5 in total and so on. |
S, No of EDA instances |
|
VM TimeZone |
The timezone to be set on VM's |
S, Time Zone |
|
NTP server IP |
S, IP address | |
|
DNS server IP |
S, IP address | |
|
Redundant NTP server IP |
IP address for the redundant external NTP server, if not used leave the default value |
S, IP address |
|
Redundant DNS server IP |
IP address for the redundant external DNS server, if not used leave the default value |
S, IP address |
3 Disk Partitioning
The following table lists configurable parameters for disk partitioning.
For information about changing size of the partitions, see System Administrators Guide for Virtual and Cloud Deployment, Reference [5].
|
Label |
Device name |
Mount point |
Size |
Description |
Type |
|---|---|---|---|---|---|
|
CAS_DATA |
/dev/vdb2 |
/var/cassandra/data |
Ephemeral storage allocated to VM during deploy time –10 GB (CAS_COMLOG) |
Cassandra Data storage. |
P |
Reference List
| [1] Glossary of Terms and Acronyms, 0033-CSH 109 628 Uen |
| [2] Customer Questionnaire for Virtual and Cloud Deployment, 2/1057-CSH 109 628 Uen |
| [3] Library Overview, 18/1553-CSH 109 628 Uen |
| [4] Network Description and Configuration for Virtual and Cloud Deployment, 1/1551-CSH 109 628 Uen |
| [5] System Administrators Guide for Virtual and Cloud Deployment, 3/1543-CSH 109 628 Uen |