| Attributes |
SeverityLevel[0..1] noNotification readOnly |
-
activeSeverity
-
The perceived severity of the alarm.
It may change during the alarm's lifetime.
Specification: RFC3877
|
AdditionalInformation[0..] noNotification readOnly |
-
additionalInfo
-
Further information about the problem.
The information is represented as a set of data structures with two items of information, an identifier and a value. It may change during the alarm's lifetime.
|
string[0..1] noNotification readOnly |
-
additionalText
-
Extra information about the alarm.
It may change during the alarm's lifetime.
|
EventType[0..1] noNotification readOnly |
-
eventType
-
General category for the alarm.
Specification: ITU-T X.733 X.736
|
string key mandatory noNotification restricted |
-
fmAlarmId
-
Holds the name used when identifying the MO.
|
DateTime[0..1] noNotification readOnly |
-
lastEventTime
-
The timestamp of when the alarm was last updated.
This is set at alarm information change or severity change.
|
uint32[0..1] noNotification readOnly |
-
majorType
-
The attributes majorType and minorType are the two key attributes used to identify the alarm type.
|
uint32[0..1] noNotification readOnly |
-
minorType
-
The attributes majorType and minorType are the two key attributes used to identify the alarm type.
|
string[0..1] noNotification readOnly |
-
originalAdditionalText
-
The additional text set when the alarm was raised.
This attribute is set when the alarm is raised and will not change during the alarm's lifetime.
|
DateTime[0..1] noNotification readOnly |
-
originalEventTime
-
The timestamp when the alarm was raised.
This attribute is set when the alarm is raised and will not change during the alarm's lifetime.
|
SeverityLevel[0..1] noNotification readOnly |
-
originalSeverity
-
The perceived severity set when the alarm was raised.
It will not change during the alarm's lifetime.
Specification: RFC3877
|
ProbableCause[0..1] noNotification readOnly |
-
probableCause
-
Qualifies and provides further information on the reason for the event.
A standard set of probableCause values is provided in the ERICSSON-ALARM-PC-MIB.
|
int64[0..1] noNotification readOnly |
-
sequenceNumber
-
A unique identity for every notification sent.
This identity changes at every notification, that is, severity change and information change. It is not the same as the fmAlarmId as multiple notifications may be sent for one alarm instance.
|
string[0..1] noNotification readOnly |
-
source
-
The distinguished name of the alarming object.
|
string[0..1] noNotification readOnly |
-
specificProblem
-
Provides further refinement to the information given by probableCause.
Can be used to find an associated operating instruction (OPI).
|