User Guide 6/1553-AXM10104/1 Uen M
[ Topics hidden with current filter selection ]

vMRF Troubleshooting Guideline
Virtual Multimedia Resource Function

Contents


1 Introduction

This document describes how to perform the troubleshooting procedure in the vMRF.

1.1 Documents

Before starting this procedure, ensure that the following documents have been read:

1.1.1 Conditions

Certain troubleshooting activities can have an impact on the node performance. For example, trace or log activation can be disturbing traffic and is not recommended without first consulting next level of maintenance support.

2 Troubleshooting Procedures

This section describes troubleshooting information for vMRF.

Problems identified that cannot be solved by using this document must be reported to the next level of maintenance support. This is to result in a Customer Service Report (CSR).

The details of the trouble reporting process is outside the scope of this document.

A manual recovery flow in Manual Recovery Flow presents a generic workflow to identify and solve problems if possible, or to collect useful data.

Trouble Cases describes specific trouble cases for various scenarios. These cases often utilize the manual recovery flow as well.

Log files of access and authorization events in the system can be collected by using the journalctl command. For more information, refer to vMRF Security Management.

It is recommended to periodically export and store the configuration of the node outside the VNF as a backup for a possible re-deployment. For more information, refer to vMRF Backup and Restore Guideline.

2.1 Manual Recovery Flow

This section describes the recommended manual recovery flow for troubleshooting purposes.

Steps

  1. Log in to the vMRF instance.
  2. Collect troubleshooting data regarding the incident in case next level support needs to be contacted. For more information on how to collect information, refer to Data Collection Guideline for vMRF.
  3. Check vMRF status, identify the faulty VM if needed. See vMRF Status Check for the procedure.
  4. Consider performing a backup. For more information refer to vMRF Backup and Restore Guideline.
  5. Lock the faulty VM. Consider graceful locking through MTAS configuration by gracefully locking the MRFP nodes in MTAS. For more information, refer to section Deactivate Gracefully in MTAS Media Control Management Guide, Reference [1]. If the VM is not available or accessible, continue with Step 7.
    Note:

    In this case the VM is locked immediately and all ongoing traffic from the VM is lost. For more information on locking a VM, refer to vMRF Configuration Management.

  6. Restart the VM from the cloud management tool.
    Note:

    If the MrfInstance MO that represents the VM is in locked state after the restart, it must be unlocked by setting the administrativeState attribute of the MO to UNLOCKED.

  7. If the problem is not solved, remove the VM from the cluster using the cloud management tool and create a new VM.

2.2 Common Procedures

This section describes procedures used during troubleshooting.

2.2.1 vMRF Status Check

This procedure describes how to verify the vMRF deployment.

The status check shows the status of all VMs in the cluster. A VM can be identified by its UUID. The UUID is visible:

2.2.1.1 vMRF Status Check on Openstack

  1. Open an SSH connection to the O&M IP address of the vMRF VNF instance using the following command:
    ssh -A -i <private key .pem file> <user ID>@<O&M IP address>
  2. Run the following command:
    cluster run verify_vmrf_node_status.py
  3. Check that all components are in the OK state.

The following example shows the printout of a successful status check:

Running command: "verify_vmrf_node_status.py" on localhost
                eth0: OK
                eth1: OK
                eth2: OK
             SC role: ACTIVE
              CoreMW: OK
                 COM: OK, RUNNING
         MrfDirector: OK, RUNNING
           CliDaemon: OK
          IpPipeline: OK
              TC-MPD: OK
            MrfAgent: OK
           CloudInit: OK
            SEC-CERT: OK
  neighbourdetection: OK

    3 Trouble Cases

    This section describes trouble cases for vMRF.

    Follow the troubleshooting workflow as shown in Figure 1.

    Deployment Related Trouble Cases Scaling Related Trouble Cases Signaling Related Trouble Cases Media Related Trouble Cases Load Related Trouble Cases Announcement Related Trouble Cases
    Figure 1   Troubleshooting Workflow

    3.1 Deployment Related Trouble Cases

    This section describes trouble cases related to deployment.

    3.1.1 VNF Does not Start

    3.1.1.1 Image Extraction Problem

    Symptom:

    Problem during image extraction.

    Possible Cause:

    Image is corrupted.

    Procedure:

    Do the following:

    Steps

    1. Verify the image using the MD5 checksum file that is provided by Ericsson.
    2. If needed, repeat the download and extraction of the vMRF package as described in the corresponding deployment guide.
    3. If the problem still exists, contact Ericsson support.

    3.1.1.2 vMRF Instantiation not Possible in OpenStack

    Symptom:

    • Heat stack creation failed due to error: No valid host found. There are not enough hosts available.

    Possible Causes:

    • Low vCPU resources

    • Low memory

    • Problem in network allocation. Compute nova log shows: Failed to allocate the network(s)

    Procedure:

    Do the following:

    Steps

    1. In case of network allocation problem, check the neutron logs and configuration. Correct the network configuration.
    2. Ensure that the environment fulfills hardware, software, and network requirements. The main requirements are listed in vMRF Infrastructure Requirements.
    3. Follow the deployment instruction described in Deployment Guide for OpenStack.
    4. If the problem still exists, contact Ericsson support.

    3.1.2 Cyclic Kernel Restart

    Symptom:

    • Cyclic kernel restart.

    Procedure:

    Do the following:

    Steps

    1. Perform the manual recovery flow procedure, as described in Manual Recovery Flow.
    2. If the problem still exists, contact Ericsson support.

    3.1.3 VM Stuck

    Symptoms:

    • ssh connection to VM is not possible:

      ssh mrsv-admin@192.160.112.15
      ssh: connect to host 192.160.112.15 port 22: No route to host
      
    • vMRF is disabled in vMTAS:

      >show  ManagedElement=1,MtasFunction=MtasFunction,⇒
      MtasMediaFramework=0,MtasMrf=0,MtasMpController=0,MtasMrfpNode=1
      MtasMrfpNode=1
         mtasMrfpNodeAdministrativeState=UNLOCKED
         mtasMrfpNodeMId="[10.52.58.222]:2944"
         mtasMrfpNodeOperationalState=DISABLED
      
    • VM console is inaccessible or console shows problems

    Procedure:

    Steps

    1. Perform the manual recovery flow procedure, as described in Manual Recovery Flow.
    2. If the problem still exists, contact Ericsson support.

    3.1.4 No Console Connection in Openstack

    Symptoms:

    • Console is not available.

    Procedure:

    Do the following:

    Steps

    1. Restart OpenStack nova services.

    3.1.5 No ssh Connection into VM

    3.1.5.1 OpenStack

    Symptom:

    • No route to host.

      ssh mrsv-admin@192.160.112.15
      ssh: connect to host 192.160.112.15 port 22: No route to host
      

    Possible Causes:

    • No IP available

    • Floating IP problem

    • Routing problem

    • Security group problem

    Procedure:

    Steps

    1. Check console connection.
    2. Check if there is an IP address for eth1.
    3. Check if the floating IP is associated with the VM.
    4. Check if ssh is enabled in the security groups of the VM.
    5. Check connectivity and routing firewalls towards the cloud environment.
    6. Perform the manual recovery flow procedure, as described in Manual Recovery Flow.
    7. If the problem still exists, contact Ericsson support.

    3.1.6 Wrong cloud-init Syntax

    Symptom:

    • cloud-init process indicates problem.

    Procedure:

    Steps

    1. Check the user-data.txt file delivered in the release package. Modify it if needed.
    2. If the problem still exists, contact Ericsson support.

    3.1.7 No Running MRF Processes on SC

    Symptom:

    • Status check shows following printout:

      Running command: "verify_vmrf_node_status.py" on localhost
                      eth0: OK
                      eth1: OK
                      eth2: OK
                   SC role: not_available
                    CoreMW: ERROR
                       COM: OK, NOT RUNNING
               MrfDirector: OK, NOT RUNNING
                 CliDaemon: OK
                IpPipeline: OK
                    TC-MPD: OK
                  MrfAgent: ERROR
                 CloudInit: NOT RUN YET
                  SEC-CERT: OK
        neighbourdetection: OK
      

    Procedure:

    Steps

    1. Perform the manual recovery flow procedure, as described in Manual Recovery Flow.
    2. If the problem still exists, contact Ericsson support.

    3.2 Scaling Related Trouble Cases

    This section describes trouble cases related to scaling.

    3.2.1 vMRF VM Joins Wrong Cluster

    Symptoms:

    • A vMRF VM joins a different network cluster

    mrsv-admin@42198368-bedd-898f-0d15-533ee8ad7dc4:~$ sudo journalctl | grep tipc
    Jan  9 00:42:18 kontron-am4024e kernel: [   36.890082] tipc: Started in network mode
    Jan  9 00:42:18 kontron-am4024e kernel: [   36.891668] tipc: Own node address <1.1.3>, network identity 4711
    Jan  9 00:42:18 kontron-am4024e kernel: [   36.893952] tipc: Enabled bearer <eth:et<eth0>, ⇒
    discovery domain <1.1.0>, priority 10
    Jan  9 00:42:18 kontron-am4024e kernel: [   36.897451] tipc: Established link <1.1.3:eth0-1.1.1:eth0> ⇒
    on network plane A
    Jan  9 00:42:18 kontron-am4024e kernel: [   36.899559] tipc: Established link <1.1.3:eth0-1.1.2:eth0> ⇒
    on network plane A

    1.1.3:eth0-1.1.1:eth0 implies problem. Correct tipc connection in vMRF is from eth0 to eth0: <1.1.10:eth0-1.1.15:eth0>

    Possible Cause:

    • Problem in cloud networking, incorrect network configuration, open network.

    Procedure:

    Steps

    1. Check and reconfigure cloud networking.

    3.3 Signaling Related Trouble Cases

    This section describes trouble cases related to signaling.

    3.3.1 No IP Address Available for Signaling

    Symptom:

    • IP address not available. Status check shows the following printout:

      Running command: "verify_vmrf_node_status.py" on localhost:
                      eth0: OK
                      eth1: OK
                      eth2: NO IPv4 ADDRESS
                   SC role: ACTIVE
                    CoreMW: OK
                       COM: OK, RUNNING
               MrfDirector: OK, RUNNING
                 CliDaemon: OK
                IpPipeline: OK
                    TC-MPD: OK
                  MrfAgent: OK
                 CloudInit: OK
                  SEC-CERT: OK
        neighbourdetection: OK
      

    Possible Causes:

    • Hardware problem

    • VLAN tagging problem

    • OpenStack configuration problem

    Procedure:

    Steps

    1. Check DHCP server.
    2. Check connectivity to DHCP server, physical connectivity, vlan tagging.
    3. Check OpenStack security groups.

    3.3.2 No Connection to NextHop

    Symptoms:

    • SCTP operational state of MRF application is disabled:

    mrsv-admin@fi2-vmrf-com-uplift-cl2:~$ cluster run cli_tool mrf_appl status
    Running command: "cli_tool mrf_appl status" on host: 192.168.0.3 (fi2-vmrf-com-uplift-cl2)
    [2017-01-09 11:50:55.383]
    
    Signalling State:
    ===================
    
    H248Interface-Id: 3 H248Interface-LDN: "MediaResourceFunction=1,MrfH248Control=1,MrfH248Interface=BLR2_16_2_mrf4" H248Interface association state: UNLOCKED
    H248Interface Service Change state: NOT_STARTED
    Sctp operational state: DISABLED
    Remote IP Address: 10.52.60.8 Remote Port: 21614
    ===================
    
    H248Interface-Id: 2 H248Interface-LDN: "MediaResourceFunction=1,MrfH248Control=1,MrfH248Interface=BLR2_16_2_mrf3" H248Interface association state: UNLOCKED
    H248Interface Service Change state: NOT_STARTED
    Sctp operational state: DISABLED
    Remote IP Address: 10.52.60.8 Remote Port: 21613
    ===================
    
    H248Interface-Id: 1 H248Interface-LDN: "MediaResourceFunction=1,MrfH248Control=1,MrfH248Interface=BLR2_16_2_mrf2" H248Interface association state: UNLOCKED
    H248Interface Service Change state: COMPLETED
    Sctp operational state: ENABLED
    Remote IP Address: 10.52.60.8 Remote Port: 21612
    ===================
    
    LocalEndpoint Id: 3
    Dscp: 40
    Local port: 2944
    ===================
    
    Sctp socket state: INITIATED.
    DHCP assigned IP: 10.52.61.219
    ===================
    
    MRF instance administrative state: UNLOCKED
    ===================
    
    Running command: "cli_tool mrf_appl status" on host: 192.168.0.4 (fi2-vmrf-com-uplift-cl2-0)
    [2017-01-09 11:50:54.517]
    
    Signalling State:
    ===================
    
    H248Interface-Id: 3 H248Interface-LDN: "MediaResourceFunction=1,MrfH248Control=1,MrfH248Interface=BLR2_16_2_mrf4" H248Interface association state: UNLOCKED
    H248Interface Service Change state: NOT_STARTED
    Sctp operational state: DISABLED
    Remote IP Address: 10.52.60.8 Remote Port: 21614
    ===================
    
    H248Interface-Id: 2 H248Interface-LDN: "MediaResourceFunction=1,MrfH248Control=1,MrfH248Interface=BLR2_16_2_mrf3" H248Interface association state: UNLOCKED
    H248Interface Service Change state: NOT_STARTED
    Sctp operational state: DISABLED
    Remote IP Address: 10.52.60.8 Remote Port: 21613
    ===================
    
    H248Interface-Id: 1 H248Interface-LDN: "MediaResourceFunction=1,MrfH248Control=1,MrfH248Interface=BLR2_16_2_mrf2" H248Interface association state: UNLOCKED
    H248Interface Service Change state: ONGOING_COLD_BOOT
    Sctp operational state: DISABLED
    Remote IP Address: 10.52.60.8 Remote Port: 21612
    ===================
    
    LocalEndpoint Id: 4
    Dscp: 40
    Local port: 2944
    ===================
    
    Sctp socket state: INITIATED.
    DHCP assigned IP: 10.52.61.215
    ===================
    
    MRF instance administrative state: UNLOCKED
    ===================

    Possible Causes:

    • VLAN tagging problem in cloud

    • VLAN tagging problem in site switches or routers

    • Physical connectivity problem

    • Security group problem

    Procedure:

    Steps

    1. Check if the MRF H.248 Link Unavailable alarm is active. Clear the alarm using the alarm instruction.
    2. Check if VM has IP address for eth2.
    3. Check that SCTP is enabled in the security groups of the VM.
    4. Check connectivity and routing firewalls towards the cloud environment.
    5. Restart mrf process from CLI: sudo systemctl restart mrf_appl.service
    6. Perform the manual recovery flow procedure, as described in Manual Recovery Flow.
    7. If the problem still exists, contact Ericsson support.

    3.3.3 No Connection to O&M IP Address

    Symptom:

    • The remote host key for the SSH connection to the O&M IP address has changed.

    @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
    @    WARNING: REMOTE HOST IDENTIFICATION HAS CHANGED!     @
    @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
    IT IS POSSIBLE THAT SOMEONE IS DOING SOMETHING NASTY!
    Someone could be eavesdropping on you right now (man-in-the-middle attack)!
    It is also possible that the RSA host key has just been changed.
    The fingerprint for the RSA key sent by the remote host is
    <fingerprint>.
    Please contact your system administrator.
    Add correct host key in ~/.ssh/known_hosts to get rid of this message.
    Offending key in ~/.ssh/known_hosts: <line number of the offending key>
    Permission denied (publickey,password).
    

    Possible Cause:

    • After manual VNF upgrade, a new VM takes the ACTIVE SC role but has a different remote host SSH key than the old VM.

    Procedure:

    Steps

    1. Remove the offending key from ~/.ssh/known_hosts using the following command:
      sed -i '<line number of the offending key>d' ~/.ssh/known_hosts

      The offending key is deleted, the warning message will not be displayed as long as the ACTIVE SC role stays in the current VNF.

    3.4 Media Related Trouble Cases

    This section describes trouble cases related to media.

    3.4.1 No Connection to Client

    Symptom:

    • Client is not reachable. Ping request from the IP address ends in timeout.

    mrsv-admin@fi1-vmrf:~$ cli_tool ipp conf
    Configuration:
    Network (id:1)               default_network
        VLAN ID                  -
        UDP Port Range           1024..65535
        Media IP IF (id:1)
            Ethdev               em1 (id:0)
            MAC                  FA:16:EE:FC:14:7A
            Link                 UP
            IP                   10.52.58.133
            Status               DHCP OK
        Media IP IF (id:2)
            Ethdev               em1 (id:0)
            MAC                  FA:16:EE:FC:14:7A
            Link                 UP
            IP                   2001:1b70:8298:2038::5
            Status               DHCP OK
            Link local           fe80::f816:eeff:fefc:147a
        Static Route (id:4)
            IP                   0.0.0.0/0
            Nexthop (id:4)
                MAC              00:30:88:11:DB:83
                IP               10.52.58.129
        Static Route (id:6)
            IP                   ::/0
            Nexthop (id:6)
                MAC              00:30:88:11:DB:83
                IP               fe80::230:88ff:fe11:db83
    mrsv-admin@fi1-vmrf:~$
    
    mrsv-admin@fi1-vmrf:~$ cli_tool ipp ping -m 1 10.52.45.129
    PING 10.52.45.129 56 bytes of data
    Timeout (3000 ms)
    mrsv-admin@fi1-vmrf:~$

    Possible Causes:

    • Problem in static route

    • Problem in client

    Procedure:

    Steps

    1. Check static route in vMRF.
    2. Check routing on site.
    3. Check client using Wireshark.
    4. Check that connection is OK:
      mrsv-admin@fi1-vmrf:~$ cli_tool ipp ping -m 1 10.52.45.129
      PING 10.52.45.129 56 bytes of data
      56 bytes from 10.52.45.129: icmp_seq=0 ttl=62 time=0 ms
      mrsv-admin@fi1-vmrf:~$

    3.5 Load Related Trouble Cases

    This section describes trouble cases related to load.

    3.5.1 Disturbances in Traffic

    Symptoms:

    • Temporary or permanent stoppage of traffic

    Possible Cause:

    • Software problem

    Procedure:

    Do the following:

    Steps

    1. Check crash dumps.

    1. Collect related data and contact Ericsson support. For more information on how to collect information, refer to Data Collection Guideline for vMRF.

    3.5.2 Speech Quality Problem

    3.5.2.1 Bandwidth Limitation

    Symptom:

    • Bad speech quality

      Bandwidth limitation can be checked by using the ipp discard-counters command:

      mrsv-admin@fi8-mrs:~$ cluster run cli_tool ipp discard-counters
      RX_BANDWIDTH_POLICING_DROP_TRAFFIC                      : 6286 
      

    Possible Cause:

    • Bandwidth limitation

    Procedure:

    Steps

    1. Check that needed bandwidth is not limited.

    3.5.2.2 Packet Loss in vSwitch

    Symptom:

    Bad speech quality.

    Possible Cause:

    • Packet loss in vSwitch.

    Procedure:

    Steps

    1. Check packet loss in vSwitch by using the ipp internals command:
      cluster run cli_tool ipp internals -l 1
       portname dir   max burst       total    discards        lost
            em1 out          64  3168760208           0      300455
      vswitch lost: 390124
      
    2. Check packet loss in vSwitch by using the cloud management tool.
    3. Add more VMs to the cluster if needed.

    3.5.2.3 Packet Loss on Site

    Symptom:

    Bad speech quality.

    Possible Causes:

    • Packet loss on site.

    • Packet loss/error counters are incremented in site switches or routers and cloud server switches.

    Procedure:

    Steps

    1. Check connectivity, configuration, VLANs, routing firewalls towards cloud environment.

    3.6 Announcement Related Trouble Cases

    This section describes trouble cases related to announcements.

    3.6.1 vMRF Cannot Play Announcement

    Symptoms:

    • vMRF cannot play announcement
    mrsv-admin@fi2-vmrf-20170116-084636-cl1:~$ cli_tool mrf_appl h248-counters
    [2017-01-17 09:36:08.190]
    
    Modify Request total: 1472180 (Emergency: 0 IEPS: 0 Priority: 0)
            Pendings: 0
            Pending limit exceeded: 0
            Retransmissions: 0
            Retransmission limit exceeded: 0
    
            24 (Emergency: 0 IEPS: 0 Priority: 0) replied with error 514 (GCP_MEDIA_GATEWAY_CANNOT_SEND_THE_SPECIFIED_ANNOUNCEMENT)
            Originated from CRH at location 66 (visible as ERR_LOC_00066 in source code)
    

    Possible Causes:

    Procedure:

    Steps

    1. Run the following command:

      cli_tool mrf_appl announcement-status --status

      Example

      mrsv-admin@fi2-vmrf-20170116-084636-cl1:~$ cli_tool mrf_appl announcement-status --status
      --------------------------------------------------------------------------------------------------------------------------------------------------
      ANNOUNCEMENT FAULTS
      --------------------------------------------------------------------------------------------------------------------------------------------------
      time                          faultId   category              announcementId      language       description
      ---------------------------------------------------------------------------------------------------------------------------------------------------
      2017-01-17T09:34:48+00:00     1         CONFIGURATION FAULT   27                  en-GB          Missing BasicAnnouncement MO configuration.
                                                                                                       Announcement requested in H.248 is not configured.
      
      ----------------------------------------------------------------------------------------------------------------------------------------------------
      
    2. Depending on the problem cause indicated in the description column, add missing MO configuration or correct the faulty logic file.

      For more information on announcement MO configuration and logic files, refer to vMRF Configuration Management.

    Reference List

    [1]

    MTAS Media Control Management Guide, 19/1553-AVA 901 29/9