Replenish Emergency Unlock Activations

Contents

1Introduction
1.1Prerequisites

2

Procedure

1   Introduction

This document describes how to replenish the Emergency Unlock activation.

The number of Emergency Unlock activations is restricted. By default, Emergency Unlock mode can only be activated twice. Once the two activations have been used, an Emergency Unlock reset key must be ordered from the Ericsson software supply organization. The corresponding key file must then be installed on the Managed Element (ME) to reset the number of Emergency Unlock activations to two.

Do!

Carefully read the following information before proceeding.

Follow these instructions when attribute activationsLeft is below 2. Do not leave the ME with activationsLeft equal to zero. Preventively run this instruction when the value is below 2. Omitting to follow these instructions can lead to future service impact on the ME.

1.1   Prerequisites

This section describes the prerequisites, which must be fulfilled before using the procedure.

1.1.1   Conditions

The following conditions must apply:

2   Procedure

To replenish the Emergency Unlock activation:

  1. Navigate to the Lm managed object, for example:

    >dn ManagedElement=NODE06ST,SystemFunctions=1,Lm=1

  2. Refresh the license inventory to ensure that the license changes are applied:

    (Lm=1)>refreshLicenseInventory

    The system returns true if the operation is successful.

  3. Verify that the value of counter activationsLeft has been reset:

    (Lm=1)>EmergencyUnlock=1

    (EmergencyUnlock=1)>show activationsLeft

    When counter activationsLeft has been reset, the system returns the following:

    activationsLeft=2

    Note:  
    The value is back to 2. Alarm License Management, Emergency Unlock Reset Key Required is cleared.

  4. If the counter has not been reset, order an extra refresh of the license inventory:

    (Lm=1)>refreshLicenseInventory

    The system returns true if the operation is successful.