1 Overview
This instruction concerns alarm handling.
1.1 License Management, Emergency Unlock Reset Key Required Alarm Description
The License Management, Emergency Unlock Reset Key Required alarm is raised when the EmergencyUnlock.activationsLeft counter is decremented.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
1 |
License Management, Emergency Unlock Reset Key Required |
Emergency Unlock mode has been activated. |
License server |
WARNING: Emergency Unlock mode can be initiated for one additional seven-day period. MAJOR: Emergency Unlock mode cannot be reactivated. |
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
393216 |
|
Managed Object Class |
|
|
Managed Object Instance |
ManagedElement=<node_name>,SystemFunctions=1,Lm=1 |
|
Specific Problem |
License Management, Emergency Unlock Reset Key Required |
|
Event Type |
qualityOfServiceAlarm (3) |
|
Probable Cause |
m3100AlarmIndicationSignal (1) |
|
Additional Text |
Emergency Unlock Reset Key required |
|
Perceived Severity |
One of the following:
|
2 Procedure
The following procedure describes how to cease a License Management, Emergency Unlock Reset Key Required alarm.
2.1 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedures in this document.
2.1.1 Documents
Before starting this procedure, ensure that the following document is available:
2.1.2 Conditions
Before starting this procedure, ensure that the following conditions are met:
A License Management, Emergency Unlock Reset Key Required alarm is raised.
No ongoing maintenance activities are affecting the node.
The reason for entering Emergency Unlock mode is known
The user ceasing the alarm has proper authority to handle configuration management of the network elements.
An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.