class Fm

ManagedElement
SystemFunctions
Fm
FmAlarm [0..]
FmAlarmModel [0..]

The root MOC of the Fault Management branch.

This MO is created by the system.

Attributes
string
key
mandatory
noNotification
restricted
fmId
Holds the name used when identifying the MO.
uint32[0..1]
heartbeatInterval = 60
The interval in seconds, with which a heartbeat notification is sent to all alarm consumers.
DateTime[0..1]
noNotification
readOnly
lastChanged
The timestamp of when any alarm was last changed.
With this attribute, an external system can determine if a resynchronization operation is needed, such as following a loss and restore of a communications link.
uint64[0..1]
noNotification
readOnly
lastSequenceNo
The last used sequence number for an alarm state change notification.
The sequence numbers are consecutive. With this attribute, an external system can determine if a resynchronization operation is needed, such as following a loss and restore of a communications link.
uint32[0..1]
noNotification
readOnly
sumCritical
Shows the number of active alarms with perceived severity 'critical'.
uint32[0..1]
noNotification
readOnly
sumMajor
Shows the number of active alarms with perceived severity ‘major’.
uint32[0..1]
noNotification
readOnly
sumMinor
Shows the number of active alarms with perceived severity ‘minor’.
uint32[0..1]
noNotification
readOnly
sumWarning
Shows the number of active alarms with perceived severity ‘warning’.
uint32[0..1]
noNotification
readOnly
totalActive
Shows the total number of currently active alarms.
This corresponds to the the total number of instantiated FmAlarm objects.