| Attributes |
string key mandatory noNotification restricted |
-
dtmfSenderServiceId
-
The value component of the RDN.
|
DtmfSenderHighFreqency
readOnly |
-
freqHighA
-
First highfrequency value.
For allowed settable frequencies, see enumeration for DtmfSenderHighFreqency.
Unit: 1 Hz
|
DtmfSenderHighFreqency
readOnly |
-
freqHighB
-
Second highfrequency value.
For allowed settable frequencies, see enumeration for DtmfSenderHighFreqency.
Unit: 1 Hz
|
DtmfSenderHighFreqency
readOnly |
-
freqHighC
-
Third highfrequency value.
For allowed settable frequencies, see enumeration for DtmfSenderHighFreqency.
Unit: 1 Hz
|
DtmfSenderHighFreqency
readOnly |
-
freqHighD
-
Fourth highfrequency value.
For allowed settable frequencies, see enumeration for DtmfSenderHighFreqency.
Unit: 1 Hz
|
DtmfSenderLowFrequency
readOnly |
-
freqLowA
-
First low frequency value.
For allowed settable frequencies, see enumeration for DtmfSenderLowFreqency.
Unit: 1 Hz
|
DtmfSenderLowFrequency
readOnly |
-
freqLowB
-
Second low frequency value.
For allowed settable frequencies, see enumeration for DtmfSenderLowFreqency.
Unit: 1 Hz
|
DtmfSenderLowFrequency
readOnly |
-
freqLowC
-
Third low frequency value.
For allowed settable frequencies, see enumeration for DtmfSenderLowFreqency.
Unit: 1 Hz
|
DtmfSenderLowFrequency
readOnly |
-
freqLowD
-
Fourth low frequency value.
For allowed settable frequencies, see enumeration for DtmfSenderLowFreqency.
Unit: 1 Hz
|
int32 |
-
highFreqLevel
=
-9
{
-40..0
}
-
Tone level for high frequencies.
Unit: 1 dBm
|
int32 |
-
lowFreqLevel
=
-11
{
-40..0
}
-
Tone level for low frequencies.
Unit: 1 dBm
|
int32 |
-
maxDuration
=
1500
{
40..60000, 327675
}
-
The maximum tone segment time.
Note that the value 327675 equals to infinite tone.
Unit: 1 ms
Dependencies: minDuration <= maxDuration and minInterworkingDuration <= maxDuration
|
int32 |
-
minDigitPause
=
70
{
40..60000
}
-
The tone pause time. Unit: 1 ms.
|
int32 |
-
minDuration
=
70
{
40..60000
}
-
The minimum tone segment time.
Unit: 1 ms
Dependencies: minDuration <= maxDuration
|