1 Alarm Description
The alarm is raised when a valid Business Line (BL) voice base license is not available in the Network License Server (NeLS) and the following conditions apply:
- The MMTel-AS is configured to serve business users (attribute mtasMmtServedSubscriberType is set to BUSINESS or BUSINESS_AND_CONSUMER).
- The basic MMTel services are enabled through the mtasMmtAdministrativeState attribute.
The alarm is cleared when at least one of the following conditions apply:
- A valid vMtasBLVoiceBase license is installed.
- Attribute mtasMmtAdministrativeState is locked.
For more information about licenses, refer to License Management and MTAS Licenses.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The Business Line AS Base license is not present. |
MTAS is unable to get license details from NeLS. |
The NeLS server is unreachable, or the license is unavailable, has expired, or is corrupted. |
NeLS server |
MTAS cannot handle Business Line AS Base services. |
|
Possible IP network issue | ||||
(1) Transport Layer Security (TLS)
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6619223 |
|
Managed Object Class |
|
|
Managed Object Instance |
MtasFunction.applicationName=MtasFunction,MtasLicenses.mtasLicenses=0 |
|
Specific Problem |
MtasMmt, Business Line AS Base License Absent |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
Unavailable(14) |
|
Additional Text |
No License found or License Server Not reachable or License expired or License Server in LOCKED mode |
|
Perceived Severity |
critical (3) |
|
Additional Info |
- |
For more information about the alarm information, refer to Handling Alarms.
2 Procedure
2.1 Handle MtasMmt, Business Line AS Base License Absent
Prerequisites
- This instruction references the following documents:
- No tools are required.
- The following conditions must apply:
- The alarm is raised.
- No ongoing maintenance activities are affecting the network or network elements.
- The user has proper authority to handle configuration management of the network elements.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
Steps
- If there is any network-related alarm on the ME, act on it first.
- If there is a License Management, Autonomous Mode Activated alarm on the ME, act on it.
- If there is a License Management, Key File Fault alarm on the ME, act on it.
- Check if a valid vMtasBLVoiceBase license (CXC4012166) is installed. For more information, refer to View License Information.
- If no license is present, or if the granted status of the license is false, and expiration shows an already elapsed date, proceed with Step 8.
- Check the alarm status, refer to Check Alarm Status. Is the alarm
still active?
Yes: Continue with the next step.
No: Proceed with Step 9.
- Perform data collection using Data Collection Tool with a Full profile. For more information, refer to Data Collection Guideline for MTAS.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.