1 Alarm Description
This alarm relates to the connection between the MTAS and a Media Resource Function Processor (MRFP) node. The connection relates to the Media Resource Function Controller (MRFC) function, described in MTAS Media Control Management Guide.
The alarm is not issued for a newly defined and unlocked MRFP, until the MRFP has performed a successful H.248 Service Change to the MTAS node.
The connection between the MTAS and an MRFP node is used by the MRFC function to provide the signalling plane with the possibility to control media in the communications handled by the MTAS. For example, to play network announcements and connect media to conference bridges, by using media resources in the MRFP.
The MRFC function is a part of the MTAS, and does not have the external Mr interface, as specified optionally in the IMS standard. The traffic operation requests are started by request from the MTAS services on an internal API, and it operates external MRFPs by use of the standard Mp interface with text encoded H.248 over SCTP over IPv4.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Communication problem between MTAS and MRFP. |
The heartbeat on the SCTP link has failed. |
The SCTP link between MTAS and MRFP node does not work properly. |
SCTP link. |
If communication problem prevents MTAS from controlling media resources, certain services are not working as expected. |
|
The MRFP node does not work properly, might not be operational. |
MRFP node. | |||
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6619168 |
|
Managed Object Class |
|
|
Managed Object Instance |
MtasFunction.applicationName=MtasFunction,MtasMrfc.mtasMrfc=0,MtasMrfp.mtasMrfp=<mrfpMoId> |
|
Specific Problem |
MtasMrfp, Connection to Remote MRFP Node Lost |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
x733LossOfSignal (8) |
|
Additional Text |
SCTP link failure, Mrfp MId, where MId indicates the MRFP Identity as configured in the MtasMrfp MOC for the MRFP, which is specified when the MRFP is installed with the MTAS. For more information, refer to Managed Object Model (MOM). |
|
Perceived Severity |
Major (4) |
For more information about the alarm information, refer to Handling Alarms.
2 Procedure
2.1 Handle MtasMrfp, Connection to Remote MRFP Node Lost
Prerequisites
- This instruction references the following documents:
- No tools are required.
- The following conditions must apply:
- The alarm is raised.
- No ongoing maintenance activities are affecting the network or network elements.
- The user has proper authority to handle configuration management of the network elements.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
Steps
- Check the status of the remote MRFP node to verify that MtasMrfpNodeAdministrativeState is set to UNLOCKED and MtasMrfpNodeOperationalState is set to ENABLED.
- Navigate to a MtasMrfpNode MO,
for example:
>dn ManagedElement=1,MtasFunction=MtasFunction,MtasMediaFramework=0,MtasMrf=0,MtasMpController=0
- Show the state of the MtasMrfpNode, for
example:
(MtasMpController=0)>show-table -m MtasMrfpNode
The following is an example output where both MRFPs are disabled and MRFP2 has been locked:
=================================================================================================== | mtasMrfpNode | mtasMrfpNodeAdministrativeState | mtasMrfpNodeOperationalState | ... | ... | ... | =================================================================================================== | MRFP1 | UNLOCKED | DISABLED | ... | ... | ... | | MRFP2 | LOCKED | DISABLED | ... | ... | ... | ===================================================================================================
- Navigate to a MtasMrfpNode MO,
for example:
- Are the MRFP node attributes set to UNLOCKED and ENABLED?
Yes: Continue with the next step.
No: Proceed with Step 4.
- Confirm that the alarm has ceased, refer to Check Alarm Status. Is the alarm
still active?
Yes: Continue with the next step.
No: Proceed with Step 6.
- Perform data collection using Data Collection Tool with a Full profile. For more information, refer to Data Collection Guideline for MTAS.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.

Contents