vDicos, Diameter Peer Node Disabled

Contents


1   Alarm Description

The alarm is raised when a Diameter peer node has been disabled.

Table 1    vDicos, Diameter Peer Node Disabled Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Diameter peer node disabled

The Diameter peer node has been disabled

Diameter peer node disabled

Peer node configuration

The communication with the peer node is lost

The alarm is cleared automatically when alarm vDicos, Diameter Own Node Disabled is raised. Alarms for peer nodes related to the own node are cleared and a new alarm is raised for the own node.

2   Procedure

2.1   Handle Alarm vDicos, Diameter Peer Node Disabled

Prerequisites

Steps

  1. Contact the network or node administrator. Is the node administratively disabled for maintenance reasons?

    Yes: Proceed with Step 8.

    No: Continue with the next step.

  2. Navigate to the DIA-CFG-NeighbourNode managed object, for example:

    >dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc

  3. Enable the Diameter peer node:

    (DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>configure

    (config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=true

    (config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit

  4. Verify the setting:

    (DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show enabled

    enabled=true
  5. Is the alarm cleared?

    Yes: Proceed with Step 8.

    No: Continue with the next step.

  6. Perform data collection, refer to Data Collection Guideline.
  7. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  8. Job is completed.