MtasCharging, Request Transmission Problem
MTAS

Contents


1   Alarm Description

The MtasCharging, Request Transmission Problem alarm is raised when an Accounting-Request (ACR) charging event buffering in Backup Handler crosses the arm threshold value of MtasChargingBufferedEventsCount. Single alarm is raised per MTAS instance when there is a connectivity problem or service unavailable for at least one of the target CDFs and the MtasChargingBufferedEventsCount crosses arm threshold value. The alarm is cleared when the connection to the charging system is restored and the number of buffered charging events decreases below the disarm threshold value.

The default arm and disarm threshold values respectively are 10000 and 8000.

The alarm is issued in the following situations:

Table 1    MtasCharging, Request Transmission Problem Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Event buffering crosses arm threshold value.

A charging request transmission has failed and charging information is sent for Backup.

Charging Server does not work properly, might not be operational.

Charging Server.

Local event buffering has limited capacity compared to the Charging Server, which can induce loss of charging information if the Charging Server cannot be reached / used for a longer time and the local buffer gets full.

Connection to the Charging Server does not work properly.

Connection to the Charging Server.

 
Note:  
The alarm can appear as a result of the maintenance activity.

Table 2    MtasCharging, Request Transmission Problem Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

6619207

Managed Object Class

MtasCharging

Managed Object Instance

MtasFunction.applicationName=MtasFunction,MtasCharging.mtasCharging=0

Specific Problem

MtasCharging, Request Transmission Problem

Event Type

qualityOfServiceAlarm (3)

Probable Cause

x733ThresholdCrossed (351)

Additional Text

MtasChargingBufferedEventsCount, charging information sent to back up. Check connection to charging system or Charging System Status.

Perceived Severity

Minor (5)

For more information about the alarm information, refer to Handling Alarms.

2   Procedure

2.1   Handle Alarm MtasCharging, Request Transmission Problem

Prerequisites

Steps

  1. The alarm is automatically cleared when all ACR events are transferred to Charging Server.

    The alarm is ceased after a maximum of 15 minutes (the granularity period of MtasThresholdMonitor) or after the Backed up ACR events count reach below the disarm threshold value (see MtasChargingBufferedEventsCount).

  2. Check the alarm status, refer to Check Alarm Status. Is the alarm still active?

    Yes: Continue with the next step.

    No: Proceed with Step 7.

  3. Check connection status to the Charging Server. The following alarms can indicate that there is a problem with the connection:
  4. Check the alarm status. Is the alarm still active?

    Yes: Continue with the next step.

    No: Proceed with Step 7.

  5. Perform data collection using Data Collection Tool with a Full profile. For more information, refer to Data Collection Guideline for MTAS.
  6. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  7. Job is completed.