1 Alarm Description
The alarm is raised when the Service Continuity As Base services are enabled through the mtasSccAdministrativeState attribute, but the license allowing use of the services is not available in the Network License Server (NeLS).
The alarm is cleared when a valid license is installed or when the mtasSccAdministrativeState attribute is disabled.
For more information about licenses, refer to License Management and MTAS Licenses.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
A Service Continuity As Base license is not present. |
MTAS is unable to get license details from NeLS. |
The NeLS server is unreachable, or the relevant license is unavailable, has expired, or is corrupted. |
NeLS server |
MTAS cannot handle Service Continuity As Base services. |
|
Possible IP network issue | ||||
(1) Transport Layer Security (TLS)
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6619237 |
|
Managed Object Class |
|
|
Managed Object Instance |
MtasFunction.applicationName=MtasFunction,MtasLicenses.mtasLicenses=0 |
|
Specific Problem |
MtasLicenses, Scc Base License Absent |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
m3100Unavailable(14) |
|
Additional Text |
No License found or License Server Not reachable or License expired or License Server in LOCKED mode |
|
Perceived Severity |
critical (3) |
|
Additional Info |
- |
For more information about the alarm information, refer to Handling Alarms.
2 Procedure
2.1 Handle MtasLicenses, Scc Base License Absent
Prerequisites
- This instruction references the following documents:
- No tools are required.
- The following conditions must apply:
- The alarm is raised.
- No ongoing maintenance activities are affecting the network or network elements.
- The user has proper authority to handle configuration management of the network elements.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
Steps
- If there is a network-related alarm on the ME, act on it first.
- If there is a License Management, Autonomous Mode Activated alarm on the ME, act on it.
- If there is a License Management, Key File Fault alarm on the ME, act on it.
- Check if a valid vMtasSccBase license (CXC4012152) is installed. For more information, refer to View License Information.
- If no license is present or if the granted status of the license is false and expiration shows an already elapsed date, proceed with Step 8.
- Check the alarm status, refer to Check Alarm Status. Is the alarm
still active?
Yes: Continue with the next step.
No: Proceed with Step 9.
- Perform data collection using Data Collection Tool with a Full profile. For more information, refer to Data Collection Guideline for MTAS.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.

Contents