1 Description
This instruction describes how to instantiate a Virtualized Network Function (VNF) using Ericsson Orchestrator (EO).
Instantiation in EO consists of preparatory steps, during which HOT files, the VNF configuration file, and other Cloud infrastructure-related input are provided. The actual instantiation is done by EO triggering an instantiation workflow in VNF-LCM.
For more information about the VNF-LCM, see MTAS VNF Lifecycle Management.
2 Procedure
2.1 Instantiate a VNF
Prerequisites
- No tools are required.
- The following condition must apply:
- The Onboard procedure is completed. For more information, see Onboard VNF Package on EO.
- The user is logged on to EO.
Steps
- In the EO, start a new Virtual Application (VAPP).
- In Resources > Packages, select the package to deploy and click Deploy.
- On the Search for Offers view, select values for the mandatory fields, and click Next.
- On the Choose Offer view, select the VNF package to be used for instantiation, and click Next.
- On the Set VIM Criteria view, click Next.
- On the Choose VIM Zone view, select the desired VIM zone, and click Next.
- On the Enter Attributes view, provide
values for the fields of the VAPP Attributes tab:
- Virtual Application Name, which is also the name of the Heat stack
- VNF Manager - The VNF Manager chosen during onboarding is pre-selected.
- Flavor - The virtual hardware configuration
of the VNF, for example: number of vCPUs and memory size.
- Note:
- The value provided for Flavor is not used at this point, but as it is a mandatory field, a dummy value must be provided.
- On the Enter Attributes view, provide the VNFD_Wrapper.json file on the Configuration tab. It is possible to overwrite the VNFD_Wrapper.json file provided during onboarding either by uploading an updated file or by modifying the attribute values on the Configuration tab.
- Click Submit Order to finalize instantiation.
Result:
On the opening window, click View Asset List to check the status of the instantiation order. EO triggers an instantiation workflow in VNF-LCM, and the VNF becomes visible in the used VNFM.- Note:
- If the EO and the VNF-LCM are in a mutually granting connection, the new instance appears in the VNF-LCM after a successful instantiation from the EO.
2.2 Troubleshooting
If the workflow execution fails, inspect the relevant logs to identify the cause of the failure.
Steps
- Increase the log level from INFO to DEBUG. For information on how to change log level, see VNF-Lifecycle Manager System Administration Guide, 1543-APR 901 0578.
- Inspect the following logs to identify the cause of the
failure:
- Jboss Server log: /ericsson/3pp/jboss/standalone/log/server.log
- System log: /var/log/messages
- Workflow log: the Workflow Log view in the VNF-LCM
- If a problem cannot be solved, consult the next level of maintenance support and provide the logs. Further actions are outside the scope of this instruction.

Contents