1 Description
This instruction describes how to terminate a Virtualized Network Function (VNF) using Ericsson Orchestrator (EO).
2 Procedure
2.1 Terminate a VNF
Prerequisites
- The following condition must apply:
Steps
- In EO, select the Virtual Application (VAPP) to terminate and click Delete.
- On the Terminate VAPP form, provide termination options, and click Terminate.
The following termination options are available:
- Graceful
The Virtual Machines (VMs) in the cluster are gracefully locked, the VNF instance gradually stops processing traffic. The VNF is terminated after the expiration of the graceful termination period.
- Forceful
The VNF is terminated immediately, all ongoing traffic is lost. This option must be confirmed on the next view, as it stops all traffic.
- Graceful termination time-out (sec)
The graceful termination time-out value defines after how many seconds the VNF is terminated when graceful termination has been applied but there is still ongoing traffic. Default value: -1, meaning that there is no graceful termination period, that is, the VNF is terminated only after all VMs stopped processing traffic.
- Note:
- Do not modify configuration data in the Configuration Parameters field.
- Graceful
- Click Terminate.
Result:
The VMs in the cluster are terminated with the method selected in Step 2, the VNF instance stops processing traffic, and is terminated.- Note:
- If the EO and the VNF-LCM are in a mutually granting connection, the new instance disappears from the VNF-LCM database after a successful termination from the EO.
2.2 Troubleshooting
If the workflow execution fails, inspect the relevant logs to identify the cause of the failure.
Steps
- Increase the log level from INFO to DEBUG. For information on how to change log level, see VNF-Lifecycle Manager System Administration Guide, 1543-APR 901 0578.
- Inspect the following logs to identify the cause of the
failure:
- Jboss Server log: /ericsson/3pp/jboss/standalone/log/server.log
- System log: /var/log/messages
- Workflow log: the Workflow Log view in the VNF-LCM
- If a problem cannot be solved, consult the next level of maintenance support and provide the logs. Further actions are outside the scope of this instruction.

Contents