SS7 CAF Process Down
Diameter Signaling Controller

Contents

1Overview
1.1Alarm Description

2

Procedure

1   Overview

This document is the Operating Instructions (OPI) for the alarm SS7 CAF Process Down.

1.1   Alarm Description

This is an alarm of severity MAJOR.

The alarm is issued when an attempt to start a process is failed.

The possible alarm causes and fault locations are explained in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

  • A process is crashed or killed.

  • ECM was unable to connect to the process after it was started.

  • A controlled takedown of the process was made.

  • Internal cluster network problems

An attempt to start a process failed.

  • Process crashed, killed or unavailable

  • Internal cluster network problems

Internal cluster network

Normally this is a non-fatal alarm; the ECM will try to start the process again.


If the alarm is raised more than 5 times within 5 minutes or is persistent for 5 minutes, follow the procedure below.

The following alarm attributes apply to this alarm:

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

1586561537

Managed Object Class

N/A

Specific Problem

Process Down

Perceived Severity

SEVERITY_MAJOR

2   Procedure

Perform the following steps if the alarm is raised multiple times or persistent:

  1. Check other alarms from the cluster about the internal cluster network status.
  2. Collect the ecm.log and ss7trace.log located in /opt/sign/log.

    Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.

  3. Contact next level of support and provide the files collected in Step 2 above.


Copyright

© Ericsson AB 2014. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
Ericsson is a trademark of Telefonaktiebolaget LM Ericsson.
All trademarks are properties of their respective owners.

    SS7 CAF Process Down         Diameter Signaling Controller