1 Overview
This document is the Operating Instructions (OPI) for the alarm SS7 CAF Start Process Failed.
1.1 Alarm Description
This is an alarm of severity MAJOR.
The alarm is issued when an attempt to start a process failed.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
An attempt to start a process failed. |
|
Internal cluster network |
Normally this is a non-fatal alarm; the ECM will automatically make new attempts to start the process. If the alarm is raised more than 5 times within 5 minutes or is persistent for 5 minutes, follow the procedure below. |
The following alarm attributes apply to this alarm:
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586561539 |
|
Managed Object Class |
N/A |
|
Specific Problem |
Start Process Failed |
|
Perceived Severity |
SEVERITY_MAJOR |
2 Procedure
Perform the following steps if the alarm is raised multiple times or is persistent:
- Collect the ss7trace.log located in /opt/sign/log.
Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.
- Contact next level of support and provide the files collected in Step 1 above.