1 Overview
1.1 Description
This operating instruction describes, using an example, how to configure Signaling System 7 defined by Intelligent Network Application Part (INAP) for the following standards:
- European Telecommunication Standard Institute (ETSI)
The procedure described in this example shows a complete configuration with usable values. For a specific customer configuration, other values may be relevant.
1.2 Prerequisites
1.2.1 Documents
For configuration parameter information, see ETSI INAP Information Model.
1.2.2 Tools
Signaling Manager is supposed to be used for module configuration. For more details, see Reference [1].
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- Configuration has been performed according to ”Configuring SS7 TCAP”, Reference [2].
2 Procedure
2.1 Configuring INAP
- Add an element on INAP. An instance of an INAP is added.
- Select the added INAP element to edit its properties.
Figure 2 Added INAP element in Signaling Manager Navigation Pane
- Note:
- You do not need to define an INAP Subsystem if you are not going to use orders on INAP Subsystems.
2.2 Configuring INAP Subsystem
- Add an element on INAP Subsystems. An instance of an INAP Subsystem called INAP Subsystem:[undef] is added.
- Note:
- As it is seen in the name of the added INAP Subsystem:[undef], the Tcap Subsystem reference is not set by default.
- Select the added INAP Subsystem:[undef], and assign the Tcap Subsystem reference.
3 Recommended SS7 Parameters
This section contains information about specific SS7 parameters or options. Most of these values will work for an SS7 stack in a running network and are not described specifically here. In some case though, parameters may need to be modified. These parameters or options are described in the table below.
3.1 INAP
The following properties can be found in Signaling System/INAP/INAP.
|
Property Name |
Recommended Value |
Comments |
|
Max Subsystems |
2 |
The maximum number of concurrent INAP subsystems |
|
Max Dialogues |
5000 |
The maximum number of dialogues available for the INAP module |
Glossary
| TCAP |
| Transaction Capabilities Application Part |
Reference List
| [1] Signaling Manager User Guide, 1553-CNA 403 0874 Uen/1 |
| [2] Configuring SS7 TCAP, 4/1543-CNA 403 0874 Uen/1 |