1 Overview
This document is the Operating Instructions (OPI) for the alarm SS7 CAF AS State Change.
1.1 Alarm Description
This is an alarm of severity MINOR.
The alarm is issued when a local or remote Logical Application (SG/AS/IPS) has changed its state.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
A local or remote Logical Application (SG/AS/IPS) has changed its state. |
|
Remote Signaling Gateway Process Remote Signaling Process |
Normally this is a non-fatal alarm. This alarm is always accompanied by SS7 CAF SP State Change alarm. |
The following alarm attributes apply to this alarm:
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586562686 |
|
Managed Object Class |
N/A |
|
Specific Problem |
SS7 CAF State Change |
|
Perceived Severity |
SEVERITY_MINOR |
2 Procedure
Perform the following steps if the alarm is raised multiple times or persistent:
- Check if there is a SS7 CAF SCTP IP Path is Down alarm for the relevant association, and fix this alarm first.
- Check if the remote SPs have been taken out of order. Check that the IP/SCTP layer works correctly.
- Check network for any disturbances on the remote side.
- Collect the ecm.log and ss7trace.log located in /storage/no-backup/ss7caf-ana90137/log.
Also collect the current configuration which is located in the folder /storage/system/config/ss7caf-ana90137/etc. Collect the file active.om.cim and all the files with the extension *.cnf.
- If remote SPs status differ from Available or the alarm is persistent, contact next level of support.