1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is raised when a Diameter peer node has been disabled, either administratively or by the system because of a fault.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Diameter peer node disabled |
The Diameter peer node has been disabled |
Diameter peer node disabled |
Not applicable |
The communication with the peer node is lost |
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2250572780 |
|
Managed Object Class |
|
|
Managed Object Instance |
ManagedElement=<node_name>,<ManagedFunction>=<FunctionId>,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=<stackId>,DIA-CFG-PeerNodeContainer=<stackId>,DIA-CFG-NeighbourNode=<hostId>#<stackId> |
|
Specific Problem |
vDicos, Diameter Peer Node Disabled |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
m3100Unavailable (14) |
|
Additional Text |
Detailed Information: Peer Node disabled by OAM, IRP Cause: 14 |
|
Perceived Severity |
minor (5) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- A vDicos, Diameter Peer Node Disabled alarm is raised.
- System authorization and authentication have passed successfully.
- Diameter configuration data is correctly defined.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
The alarm is cleared automatically when alarm vDicos, Diameter Own Node Disabled is raised. Alarms for peer nodes related to the own node are cleared and a new alarm is raised for the own node.
Do the following:
- Navigate to the DIA-CFG-NeighbourNode managed object, for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc
- Enter Config mode:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>configure
- Enable the peer node:
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=true
- Commit the setting:
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit
- Verify the setting:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show enabled
enabled=true
- Is the alarm cleared?
Yes: Proceed with Step 9.
No: Continue with the next step.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.