vDicos, Diameter Peer Node Disabled

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

The alarm is raised when a Diameter peer node has been disabled, either administratively or by the system because of a fault.

The possible alarm causes and fault locations are explained in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Diameter peer node disabled

The Diameter peer node has been disabled

Diameter peer node disabled

Not applicable

The communication with the peer node is lost

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

2250572780

Managed Object Class

DIA-CFG-NeighbourNode

Managed Object Instance

ManagedElement=<node_name>,<ManagedFunction>=<FunctionId>,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=<stackId>,DIA-CFG-PeerNodeContainer=<stackId>,DIA-CFG-NeighbourNode=<hostId>#<stackId>

Specific Problem

vDicos, Diameter Peer Node Disabled

Event Type

communicationsAlarm (2)

Probable Cause

m3100Unavailable (14)

Additional Text

Detailed Information: Peer Node disabled by OAM, IRP Cause: 14

Perceived Severity

minor (5)

1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

This instruction references the following documents:

1.2.2   Tools

No tools are required.

1.2.3   Conditions

Before starting this procedure, ensure that the following conditions are met:

2   Procedure

The alarm is cleared automatically when alarm vDicos, Diameter Own Node Disabled is raised. Alarms for peer nodes related to the own node are cleared and a new alarm is raised for the own node.

Do the following:

  1. Navigate to the DIA-CFG-NeighbourNode managed object, for example:

    >dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc

  2. Enter Config mode:

    (DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>configure

  3. Enable the peer node:

    (config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=true

  4. Commit the setting:

    (config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit

  5. Verify the setting:

    (DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show enabled

    enabled=true
  6. Is the alarm cleared?

    Yes: Proceed with Step 9.

    No: Continue with the next step.

  7. Perform data collection, refer to Data Collection Guideline.
  8. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  9. Job is completed.


Copyright

© Ericsson AB 2015, 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    vDicos, Diameter Peer Node Disabled