1.1 Description
The alarm is issued when a signaling link has been deactivated by an operator. It has been taken out of service.
|
Major type |
193 |
|
Minor type |
1586562568 |
|
MO Class |
N/A |
|
Specific Problem |
Link Deactivated |
|
Severity |
SEVERITY_MINOR |
The possible causes are as follows:
- An operator has sent the link deactivation order for this link.
No remedial action is required.
1.2 Prerequisites
1.2.1 Documents
Before starting this procedure, make sure that you have read the following documents:
- "Fault Management User Guide" (24/1553-APR 901 0315/2 Uen)
- "Configuring SS7, System Components" (7/1543-CNA 403 0874/1 Uen)
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
Perform the following steps:
- This is a result of the operators actions, a syslog is recorded, and the link is no longer available to traffic.
- Once dead, links may be reactivated by operator intervention.