class Fm

ManagedElement
+-SystemFunctions
+-Fm
+-FmAlarm [0..]
+-FmAlarmModel [0..]

The root MOC of the Fault Management branch.

This MO is created by the system.

Attributes
string
key
mandatory
noNotification
restricted
fmId
The value component of the RDN.
uint32[0..1]
heartbeatInterval = 60
The interval in seconds, with which a heartbeat notification is sent to all alarm consumers.
DateTime[0..1]
noNotification
readOnly
lastChanged
The timestamp of when any alarm was last changed.
With this attribute, an external system can determine if a resynchronization operation is needed, such as following a loss and restore of a communications link.
uint64[0..1]
noNotification
readOnly
lastSequenceNo
The last used sequence number for an alarm state change notification.
The sequence numbers are consecutive. With this attribute, an external system can determine if a resynchronization operation is needed, such as following a loss and restore of a communications link.
uint32[0..1]
noNotification
readOnly
sumCritical
Shows the number of active alarms with perceived severity 'critical'.
uint32[0..1]
noNotification
readOnly
sumMajor
Shows the number of active alarms with perceived severity ‘major’.
uint32[0..1]
noNotification
readOnly
sumMinor
Shows the number of active alarms with perceived severity ‘minor’.
uint32[0..1]
noNotification
readOnly
sumWarning
Shows the number of active alarms with perceived severity ‘warning’.
uint32[0..1]
noNotification
readOnly
totalActive
Shows the total number of currently active alarms.
This corresponds to the the total number of instantiated FmAlarm objects.

  class Fm