1   Introduction

1.1   Scope

This document provides description about the internal and external connectivity of the MTAS product that is designed around the generic security principles and design rules of the Ericsson IMS System. The document also describes how these can be realized on cloud environments.

1.2   IMS Security Principles

This section describes the IMS security principles.

1.2.1   Network Architecture

Figure 1 shows the architecture of the IMS security principles in terms of modules. The IMS Central and Remote Modules are introduced to describe options for placing the IMS nodes in geographically dispersed sites in the network of an operator. A module is a grouping of nodes and infrastructure equipment that are placed in the same site.

Figure 1   IMS Network Modules

Principle 1 - MTAS is placed in an IMS Central Module

1.2.2   Network Domain Security

Network Domain Security (NDS) provides access control to the network and in particular to the sites where the Network Elements (NE) and nodes reside. The whole network is partitioned into Security Domains (SD). The different NEs are placed in different SDs based on their functionality and level of trust. Different NDS security functions at the border of each Security Domain, in the backbone and also internally within each Security Domain are applied. Only legitimate traffic is allowed to pass from one Security Domain to another by enforcing control policies for all inter-Security Domains traffic.

Apart from the IP backbone, three security domains are defined:

Figure 2   IMS Security Domains

Principle 2 - MTAS belongs to the Service and Control IMS Security Domain

1.2.3   Traffic Separation

The IMS traffic is divided into separate networks according to the traffic type and the level of security. Traffic in each category is transported over its own IP network (VPN) separated from traffic classified to other categories and IP networks.

The following is a list of VPN groups in the IMS network:

Figure 3   Traffic Separation and VPNs

The DMZ VPNs and the SC VPNs are site-internal. That is, they are not extended over the backbone. The DMZ VPNs interconnect the nodes in the DMZ SD with the switches and the IMS firewall. The SC VPNs interconnect the nodes in the S&C SD with the switches and the IMS firewall.

The CN VPNs and the Ext VPNs, span the backbone and interconnect IMS modules in different sites. These VPNs interconnect the nodes in the M&G SD with the switches, IMS firewall, and the Site Routers. The CN VPNs traverse the backbone and interconnect nodes in different IMS Modules. The Ext VPNs interconnect the IMS modules with networks that are considered ‘not trusted’.

Principle 3 - MTAS is providing its services through the SC VPNs (OM_SC and Sig_SC)

1.2.4   MTAS External Interfaces

The MTAS included SCC, Conference, ST, and MMTel IMS application servers are providing various type of services over the logical interfaces, shown in Figure 4.

Figure 4   Interfaces and Protocols Supported by MTAS

The Service Access Points are single-homed IPv4/IPv6 UDP/TCP/SCTP sockets that are bound to the OM_SC and Sig_SC VPNs as follows (VPNIP → logical interface).

1.3   Cloud Deployment Generic Principles

This section describes the generic principles related to cloud deployment.

1.3.1   Design Objectives

1.3.2   MTAS Virtual Network Function

The MTAS application system as Virtual Network Function (VNF) is built up from Virtual Machines in a 2+N-Way fashion. The supported minimum configuration is 2+2, meaning that 2 x SCs and 2 x PLs must exist in the system. The maximum configuration is 2+73 (2 x SCs and 73 x PLs). The VMs must be created on separate failure domains, on different Compute Nodes.

Figure 5   MTAS Virtual Network Function

The VMs are partitioned into a Non-elastic and an Elastic segment.

The cloud infrastructure-provided virtual network ports (→ vNICs) are used by the VMs as follows:

The details about vNICs use are provided in the next chapters.

2   MTAS Internal Communication

This section provides a description about how the MTAS VNF internal communication is accomplished, no matter of what product is providing the underlying cloud infrastructure.

All the VMs within the MTAS VNF are connected to the "<MTAS VNF>_internal" virtual network through the eth0 interface.

Figure 6   "<MTAS VNF>_internal" virtual network

2.1   TIPC

TIPC is accommodated for inter-process communication by a set of software components.

Figure 7   "<MTAS VNF>_internal" virtual network - TIPC

Upon the installation procedure, the rather simple TIPC logical network topology is established within the MTAS VNF automatically. The VMs, as TIPC nodes, are connected to each other in a full-meshed fashion through point-to-point links in Cluster = 1, Zone = 1.

2.2   INET IPv4

The IPv4 based communication is another intra-cluster communication pattern that the system is heavily dependent on.

Figure 8   "<MTAS VNF>_internal" virtual network - INET IPv4

The system is using the 169.254.100.0/24 subnet over the "<MTAS VNF>_internal" virtual network infrastructure. Address allocation is secured by MTAS VNF internal mechanism, has no dependency on the DHCP service what the cloud infrastructure can provide. On the "<MTAS VNF>_internal" network, the DHCP service is given by the System Controllers to each other and for all PLs in a redundant fashion.

Attention!

Risk of system malfunction or traffic disturbance.

The cloud infrastructure must secure that the DHCP communication (BOOTP; UDP src/dst port: 67/68) is not filtered on the "<MTAS VNF>_internal" virtual network.

2.2.1   INET IPv4 MIP Aliases for TFTP Purpose

As a completion of the MTAS VNF internal PXE bootstrap mechanism, the System Controllers are also presenting TFTP service to each other and for all PLs in a two-way active load shared manner. The service is bound to a Movable IP (MIP) address on the "<MTAS VNF>_internal" network.

Figure 9   "<MTAS VNF>_internal" virtual network - TFTP over INET IPv4

Load sharing is achieved through allocating a MIP address to each System Controller. If there is an SC failure, the system automatically assigns both MIP addresses to the remaining SC.

2.2.2   INET IPv4 MIP Alias for NFS Purpose

System Controllers are providing NFS service to each other and for all PLs in a 1+1 redundant manner. The service is bound to a Movable IP (MIP) address on the "<MTAS VNF>_internal" network.

Figure 10   "<MTAS VNF>_internal" virtual network - NFS over INET IPv4

If there is an SC failure, the system automatically reassigns the NFS MIP address and starts the NFS service on the redundant SC pair.

2.2.3   INET IPv4 MIP Alias for Common Parts IPC Purpose

Common Parts IPC is an INET IPv4 based communication method within the MTAS VNF. A piece of internal component, called Common Parts Manager (CP-M) is providing services for the clients (Common Parts Client; CP-C). The Service Access Point of CP-M is bound to a well-know IPv4 address on the "<MTAS VNF>_internal" network. CP-M is available on either of the available PLs.

Figure 11   "<MTAS VNF>_internal" virtual network - CP-M

When the PL that is hosting the CP-M goes down for any reason (failure, scale in), the system automatically reassigns the CP-M MIP address and starts the CP-M on another PL.

2.3   INET IPv6 over MAC VLAN

Specific SW components that are running on the VMs of the MTAS VNF use Linux Containers (LXCs) to separate their functionality from the rest.

Figure 12   "<MTAS VNF>_internal" virtual network - INET IPv6 over MAC VLANs

The LXC networking is facilitated over MAC VLANs in bridge mode. The bridges are created on the vNIC (eth0) that is bound to the "<MTAS VNF>_internal" network. On L3 level, the communication is performed on the IPv6 link-local network. The MAC aliases (in Figure 12, A11 ... An2) for the LXC containers are defined through IPv6 link-local to MAC address conversion.

Because of bridge mode, the communication between two LXC containers that are on the same VM remains within the VM. But this is not the case between LXC containers that are residing on different VMs.

Attention!

Risk of system malfunction or traffic disturbance.

If the underlying cloud infrastructure is performing traffic policing based on Cloud Infrastructure Controller aware, virtual network port assigned vNIC MAC addresses, the policy rule set is to be loosened/extended. It must be secured that the communication between the VNF internal MAC aliases is not filtered by any means.

3   MTAS External Communication

This section provides a description about how MTAS VNF external communication can be accomplished. In such a scenario when the external connectivity is secured by soft routers, the deployment of the Software router VMs must take place on dedicated compute nodes, referred as "Network Nodes", to not cause background load for any of the MTAS VNF VMs.

3.1   Operation and Maintenance

3.1.1   Overview

The purpose of having this infrastructure in place is as follows:

Figure 13   MTAS VNF System Management Infrastructure

3.1.2   Routing Design

All the VMs within the MTAS VNF are connected to the "<MTAS VNF>_OM_int" virtual network infrastructure through their eth1 interfaces. This infrastructure is internal and shared with the Soft Router instances. A fixed primary IP address is assigned to all the connected virtual network ports/vNICs from the "<MTAS VNF>_OM_int_subnet_IPv4/6" link-local subnet.

Additional IPv4/6 addresses are assigned to the connected eth1 of the SC (SC-1_IPv4/6, SC-2_IPv4/6) and the soft router interfaces (GW1, GW2) on the created broadcast domain. These addresses are taken from the "<MTAS VNF>_OM_subnet_IPv4/6" routable subnet whereby transit is enabled by a VRRP protected gateway (OM_gateway_IPv4/6). By setting the default route against this VRRP IP on the SCs, the system management connectivity of them can be secured at once.

Beside the SC and GW addresses, there is another address reserved and shared by the System Controllers, the OM_IPv4/6 (also referred as "Muta MIP") that is active on SC where the VNF is actually providing its operation and maintenance services over the COM CLI/Netconf/SNMP interfaces.

The single point of operation and maintenance access is guaranteed for the COM NBI related inbound and outbound streams. For the outbound streams (UDP: SNMP Trap; TCP: SFTP) it is secured by indicating the OM_IPv4/6 Movable IP as the preferred source address in the default route setting. This preference is only used on the SC where the MIP is active.

Attention!

Risk of system malfunction or traffic disturbance.

The "<MTAS VNF>_OM_subnet_IPv4/6" subnet is such an overlay what the virtual networking service of the cloud environment is not aware of. Therefore, the virtual networking service must guarantee that the traffic on the subnet other than "<MTAS VNF>_OM_int_subnet_IPv4/6" is also passing through the connected virtual ports.

As long as the virtual networking firewall service is globally inactivated for other reasons, it is not an issue at all. However, if it is turned on, firewall exceptional rules must be defined for every connected port on the "<MTAS VNF>_OM_int" virtual network infrastructure (in the OpenStack case, use "allowed_address_pairs" setting on Neutron ports; the "<MTAS VNF>_OM_subnet_IPv4/6" subnet to be defined in a CIDR notation).

Note:  
The infrastructure for operation and maintenance is designed by taking an OpenStack specific issue into consideration: Neutron does not allow creating more ports on a virtual network infrastructure than the available number of IP hosts on the connected IP subnet. However, for the benefit of unified product follow-up activities (cloud infrastructure agnostic unified network design), the approach must be adopted in VMware environment too.

The "<MTAS VNF>_OM_subnet_IPv4/6" to be advertised through OSPF in the same pair of routing process instances that are used to handle VIP external connectivity in the OM_SC VPN. For additional details, see the next section.

3.2   Virtual IP Access - OM_SC VPN

3.2.1   Overview

The purpose of having this infrastructure in place is to secure connectivity to the MTAS services that are bound to Virtual IPs available through the OM_SC VPN. These services are:

The VMs that are playing the role of PL, but maximum 4 at any given moment, are connected to the "<MTAS VNF>_om_sc_sp" virtual network through the eth2 interface. Routing can either be dynamic or static on this infrastructure; dynamic is preferred. Mixed routing fashion is not supported in the IPv4/IPv6 dual-stack scenario. That is: either use dynamic for both IPv4 and IPv6, or use static for both of IPv4 and IPv6.

3.2.2   Dynamic Routing Design

The dynamic routing reference design is considering the following constraints:

Figure 14   MTAS VNF Virtual IP Access - OM_SC VPN, dynamic routing design

The 'om_sc_sp_vr1' and 'om_sc_sp_vr2' routing instances are ABRs in two areas:

Preferably, OSPF must be combined with BFD to achieve faster forwarding path failure detection.

3.2.3   Static Routing Design

Using static routing over the <MTAS_VNF>_om_sc_sp infrastructure is an option if the soft routers are supporting BFD. The following constraints are considered:

Figure 15   MTAS VNF Virtual IP Access - OM_SC VPN, static routing design

The connected PLs embedded routing instances are split into two groups; two routing instances in each group.

The routes towards the VIP addresses are injected into OSPF by the Soft Routers.

3.3   Virtual IP Access - Sig_SC VPN

3.3.1   Overview

The purpose of having this infrastructure in place is to secure connectivity to the MTAS services that are bound to Virtual IPs available through the Sig_SC VPN. These services are:

The VMs that are playing the role of PL, but maximum 4 at any given moment, are connected to the "<MTAS VNF>_sig_sc_sp" virtual network through the eth3 interface. Routing can either be dynamic or static on this infrastructure; dynamic is preferred. Mixed routing fashion is not supported in the IPv4/IPv6 dual-stack scenario. That is: either use dynamic for both IPv4 and IPv6, or use static for both of IPv4 and IPv6.

3.3.2   Routing Design

The routing can be designed in a similar fashion as in case of the OM_SC VPN, along with the Sig_SC VPN-related entities (VIP addresses, networks) as they are depicted in the following figure:

Figure 16   MTAS VNF Virtual IP Access - Sig_SC VPN

The dynamic/static VIP routing aspects are not detailed nor repeated in Figure 16, refer to Section 3.2.2 Dynamic Routing Design and Section 3.2.3 Static Routing Design.

3.4   External Connectivity Through ASIC Routers

In specific environments, there be legacy ASIC routers available and the intention is, for performance and cost saving reasons, or both, to (re)use them for providing redundant L3 functions. This chapter describes on a high level how such switching/routing environment can be established.

3.4.1   Operation and Maintenance

This chapter describes how the operation and maintenance external connectivity looks like in such an L2/L3 eco-system whereby the redundant L3 functions are provided by ASIC routers.

Figure 17   MTAS VNF System Management Infrastructure Through ASIC L3

The L3 functions are placed into Virtual Router Functions (VRFs) those are created/managed in physically separated, redundant ASIC routers. The segmentation ID and the VLAN ID of the "<MTAS VNF>_OM_int" infrastructure is agreed between the administrators of the Cloud Infrastructure and the ASIC routers.

The routing principles are the same as depicted in Section 3.1. The only difference is: while in case of soft routers the "<MTAS VNF>_OM_int" infrastructure is shared by the MTAS- and the soft router VNFs, in the connected ASIC router scenario, the "<MTAS VNF>_OM_int" network remains private for the MTAS VNF. The VRFs are connected to the network segment (-> VLAN) in a "hidden" manner; those are not appearing as managed cloud resources for any of the cloud services (including Nova, Neutron, ...).

3.4.2   Virtual IP Access

On OM_SC VPN, this chapter describes how the Virtual IP external connectivity looks like in such an L2/L3 eco-system whereby the redundant L3 functions are provided by ASIC routers. The setup is the same in the Sig_SC VPN.

Figure 18   MTAS VNF Virtual IP Access Through ASIC L3 - OM_SC VPN

The L3 functions are placed into Virtual Router Functions (VRFs) those are created/managed in physically separated, redundant ASIC routers. The segmentation ID and the VLAN ID of the "<MTAS VNF>_om_sc_sp" infrastructure is agreed between the administrators of the Cloud Infrastructure and the ASIC routers.

The routing principles are the same as depicted in Section 3.2 (and in Section 3.3). The only difference is: while in case of soft routers the "<MTAS VNF>_om_sc_sp" infrastructure is shared by the MTAS- and the soft router VNFs, in the connected ASIC router scenario, the "<MTAS VNF>_om_sc_sp" network remains private for the MTAS VNF. The VRFs are connected to the network segment (-> VLAN) in a "hidden" manner; those are not appearing as managed cloud resources for any of the cloud services (including Nova, Neutron, ...).

3.5   Appendix - Configuration Templates

The VIP independent system management and Operation and Maintenance infrastructure is established upon the orchestration of the MTAS VNF. For that, the site-specific details to be provided through the orchestration engine of the given cloud infrastructure. For further details, refer to MTAS SW Installation.

Once MTAS is deployed, the Virtual IP access specifics can be configured over the COM NBI interface. For that, follow the below steps.

3.5.1   Create Floating EvipNodes

Floating EvipNodes cannot be predefined at design time, since their priority cannot be changed once they exist. However, their priority must be adjusted in-line with the chosen VIP routing strategy. Set the priorities as follows (EvipNode(s) / priority):

By substituting the priorities into the below template, issue the commands over the COM NBI.

ManagedElement=1,Transport=1,Evip=1,EvipDeclarations=1,EvipCluster=1
EvipNode=3
distribution="floating"
floatPriority="<priority>"
up
EvipNode=4
distribution="floating"
floatPriority="<priority>"
up
EvipNode=5
distribution="floating"
floatPriority="<priority>"
up
EvipNode=6
distribution="floating"
floatPriority="<priority>"
up
EvipNode=7
distribution="floating"
floatPriority="<priority>"
up
EvipNode=8
distribution="floating"
floatPriority="<priority>"
up
EvipNode=9
distribution="floating"
floatPriority="<priority>"
up
EvipNode=10
distribution="floating"
floatPriority="<priority>"
up
EvipNode=11
distribution="floating"
floatPriority="<priority>"
up
EvipNode=12
distribution="floating"
floatPriority="<priority>"
top
commit -s

Note:  
Modifying the floatPriority attribute of predefined EvipNode Managed Object Instances can be possible in a later MTAS release.

3.5.2   Create LBEs and SEs

Load Balancer and Security Elements cannot be created until floating EvipNodes do not exist. Create these entities by issuing the following commands

ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=mtas_om,EvipLbes=1
EvipLbe=lbe_1
node="3"
up
EvipLbe=lbe_2
node="4"
up
EvipLbe=lbe_3
node="5"
up
EvipLbe=lbe_4
node="6"
up
EvipLbe=lbe_5
node="7"
up
EvipLbe=lbe_6
node="8"
up
EvipLbe=lbe_7
node="9"
up
EvipLbe=lbe_8
node="10"
up
EvipLbe=lbe_9
node="11"
up
EvipLbe=lbe_10
node="12"
top
commit -s
ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=mtas_om,EvipSes=1
EvipSe=se_1
node="3"
up
EvipSe=se_2
node="4"
up
EvipSe=se_3
node="5"
up
EvipSe=se_4
node="6"
up
EvipSe=se_5
node="7"
up
EvipSe=se_6
node="8"
up
EvipSe=se_7
node="9"
up
EvipSe=se_8
node="10"
up
EvipSe=se_9
node="11"
up
EvipSe=se_10
node="12"
top
commit -s
ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=mtas_sig,EvipLbes=1
EvipLbe=lbe_1
node="3"
up
EvipLbe=lbe_2
node="4"
up
EvipLbe=lbe_3
node="5"
up
EvipLbe=lbe_4
node="6"
up
EvipLbe=lbe_5
node="7"
up
EvipLbe=lbe_6
node="8"
up
EvipLbe=lbe_7
node="9"
up
EvipLbe=lbe_8
node="10"
up
EvipLbe=lbe_9
node="11"
up
EvipLbe=lbe_10
node="12"
top
commit -s
ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=mtas_sig,EvipSes=1
EvipSe=se_1
node="3"
up
EvipSe=se_2
node="4"
up
EvipSe=se_3
node="5"
up
EvipSe=se_4
node="6"
up
EvipSe=se_5
node="7"
up
EvipSe=se_6
node="8"
up
EvipSe=se_7
node="9"
up
EvipSe=se_8
node="10"
up
EvipSe=se_9
node="11"
up
EvipSe=se_10
node="12"
top
commit -s

3.5.3   Define the VIP Addresses

ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=mtas_om,EvipVips=1
EvipVip=<OM VIP IPv4 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<OM VIP IPv6 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<CAI3G VIP IPv4 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<CAI3G VIP IPv6 Address>
deflt="no"
equivSrcAddr="no"
top
commit -s
ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=mtas_sig,EvipVips=1
EvipVip=<Traffic VIP IPv4 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<Traffic VIP IPv6 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<Ut VIP IPv4 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<Ut VIP IPv6 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<SIGTRAN1 VIP IPv4 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<SIGTRAN1 VIP IPv6 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<SIGTRAN2 VIP IPv4 Address>
deflt="no"
equivSrcAddr="no"
up
EvipVip=<SIGTRAN2 VIP IPv6 Address>
deflt="no"
equivSrcAddr="no"
top
commit -s

3.5.4   Create the FEE Elements

The FEE elements are carrying the MTAS VNF embedded routing instances (four FEEs in both VPNs -> ALBs), as they are referred to in the document. The following chapters are providing instructions how to define them, depending on the chosen VIP routing strategy.

3.5.4.1   Dynamic Routing

A FEE element using dynamic routing can be created by using the following template:

ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=<ALB name>,EvipFees=1,EvipFee=<FEE ID>
externalInterface="<Interface ID>"
extIfBridging="0"
node="<EvipNode ID>"
EvipRoutingSetup=ospfv2
EvipParam=local_address
value="<Local IPv4 address (in CIDR notation)>"
up
EvipParam=area
value="<Area ID>"
up
EvipParam=area_type
value="stub"
up
EvipParam=router_id
value="<Router ID>"
up
EvipParam=router_priority
value="0"
up
up
EvipRoutingSetup=bfd_ospfv2
EvipParam=bfd_interval
value="300"
up
EvipParam=echo
value="no"
up
EvipParam=minrx
value="300"
up
EvipParam=multiplier
value="3"
up
up
EvipRoutingSetup=ospfv3
EvipParam=area
value="<Area ID>"
up
EvipParam=area_type
value="stub"
up
EvipParam=router_id
value="<Router ID>"
up
EvipParam=router_priority
value="0"
up
up
EvipRoutingSetup=bfd_ospfv3
EvipParam=bfd_interval
value="300"
up
EvipParam=echo
value="no"
up
EvipParam=minrx
value="300"
up
EvipParam=multiplier
value="3"
top
commit -s

Create all the FEE elements by following the template and substituting the parameter values that are taken from Table 1.

Table 1    Summary of FEE elements within the MTAS VNF, dynamic routing

ALB Name

FEE ID

Interface ID

EvipNode ID

Local IPv4 Address

OSPFv2 Area ID

OSPFv2 Router ID

OSPFv3 Area ID

OSPFv3 Router ID

mtas_om

fee_1

eth2

3

<for example 10.0.12.1/25>

<for example 0.1.1.1>

<for example 1.1.1.1>

<for example 0.1.1.1>

<for example 1.1.1.1>

mtas_om

fee_2

eth2

4

<for example 10.0.12.2/25>

<for example 0.1.1.1>

<for example 1.1.1.2>

<for example 0.1.1.1>

<for example 1.1.1.2>

mtas_om

fee_3

eth2

5

<for example 10.0.12.3/25>

<for example 0.1.1.1>

<for example 1.1.1.3>

<for example 0.1.1.1>

<for example 1.1.1.3>

mtas_om

fee_4

eth2

6

<for example 10.0.12.4/25>

<for example 0.1.1.1>

<for example 1.1.1.4>

<for example 0.1.1.1>

<for example 1.1.1.4>

mtas_sig

fee_1

eth3

3

<for example 10.1.12.1/25>

<for example 0.0.1.1>

<for example 1.1.1.1>

<for example 0.0.1.1>

<for example 1.1.1.1>

mtas_sig

fee_2

eth3

4

<for example 10.1.12.2/25>

<for example 0.0.1.1>

<for example 1.1.1.2>

<for example 0.0.1.1>

<for example 1.1.1.2>

mtas_sig

fee_3

eth3

5

<for example 10.1.12.3/25>

<for example 0.0.1.1>

<for example 1.1.1.3>

<for example 0.0.1.1>

<for example 1.1.1.3>

mtas_sig

fee_4

eth3

6

<for example 10.1.12.4/25>

<for example 0.0.1.1>

<for example 1.1.1.4>

<for example 0.0.1.1>

<for example 1.1.1.4>

Note:  
The IP addresses, Area IDs, and Router IDs are site-specific, an alignment is required. The other parameters (ALB name, FEE ID, Interface ID, and EvipNode ID) must not be changed.

3.5.4.2   Static Routing

A FEE element using static routing can be created by using the following template:

ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=<ALB name>,EvipFees=1,EvipFee=<FEE ID>
externalInterface="<Interface ID>"
extIfBridging="0"
node="<EvipNode ID>"
EvipRoutingSetup=bfd_static
EvipParam=multiplier
value="3"
up
EvipParam=minrx
value="300"
up
EvipParam=local_address
value="<Local IPv4 address (in CIDR notation)>"
up
EvipParam=gateway
value="<GW IPv4 address>"
up
EvipParam=echo
value="no"
up
EvipParam=bfd_interval
value="300"
up
up
EvipRoutingSetup=bfd_static6
EvipParam=multiplier
value="3"
up
EvipParam=minrx
value="300"
up
EvipParam=local_address
value="<Local IPv6 address (in CIDR notation)>"
up
EvipParam=gateway
value="<GW IPv6 address>"
up
EvipParam=echo
value="no"
up
EvipParam=bfd_interval
value="300"
top
commit -s

Create all the FEE elements by following the template and substituting the parameter values that are taken from Table 2.

Table 2    Summary of FEE elements within the MTAS VNF, static routing

ALB Name

FEE ID

Interface ID

EvipNode ID

Local IPv4 Address

GW IPv4 Address

Local IPv6 Address

GW IPv6 Address

mtas_om

fee_1

eth2

3

<for example 10.0.12.1/25>

<for example 10.0.12.125>

<for example fd00:0:a00:c00::1/64>

<for example fd00:0:a00:c00::fffd/64>

mtas_om

fee_2

eth2

4

<for example 10.0.12.2/25>

<for example 10.0.12.126>

<for example fd00:0:a00:c00::2/64>

<for example fd00:0:a00:c00::fffe/64>

mtas_om

fee_3

eth2

5

<for example 10.0.12.3/25>

<for example 10.0.12.125>

<for example fd00:0:a00:c00::3/64>

<for example fd00:0:a00:c00::fffd/64>

mtas_om

fee_4

eth2

6

<for example 10.0.12.4/25>

<for example 10.0.12.126>

<for example fd00:0:a00:c00::4/64>

<for example fd00:0:a00:c00::fffe/64>

mtas_sig

fee_1

eth3

3

<for example 10.1.12.1/25>

<for example 10.1.12.125>

<for example fd00:0:a01:c00::1/64>

<for example fd00:0:a01:c00::fffd/64>

mtas_sig

fee_2

eth3

4

<for example 10.1.12.2/25>

<for example 10.1.12.126>

<for example fd00:0:a01:c00::2/64>

<for example fd00:0:a01:c00::fffe/64>

mtas_sig

fee_3

eth3

5

<for example 10.1.12.3/25>

<for example 10.1.12.125>

<for example fd00:0:a01:c00::3/64>

<for example fd00:0:a01:c00::fffd/64>

mtas_sig

fee_4

eth3

6

<for example 10.1.12.4/25>

<for example 10.1.12.126>

<for example fd00:0:a01:c00::4/64>

<for example fd00:0:a01:c00::fffe/64>

Note:  
The IP addresses are site-specific, an alignment is required. The other parameters (ALB name, FEE ID, Interface ID, and EvipNode ID) must not be changed.

3.5.5   Create Flow Policies

After performing all of the configurations, the Service Access Points (representations of the MTAS Logical Interfaces) are still closed. To enable incoming streams passing through the mtas_om and mtas_sig containers (ALBs), flow policies must be defined.

3.5.5.1   Flow Policies for TCP/UDP

Flow policies for incoming TCP/UDP streams can be created by using the following template:

ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=<ALB name>,EvipFlowPolicies=1,EvipFlowPolicy=<FlowPolicy ID>
dest=<VIP address>
addressFamily=<Address family>
protocol=<Protocol family>
destPort=<DST port>
targetPool=<Target pool>
top
commit -s

Create all the required flow policies, in-line with Table 3. Refer to MTAS Hardening Guide for further details regarding MTAS supported TCP/UDP SAPs.

Table 3    Summary of MTAS flow policies for incoming TCP/UDP streams

ALB Name

FlowPolicy ID

Protocol Family

DST Port

Target Pool

Address Family

VIP Address

mtas_om

ProvisioningLDAP

tcp

17323

PLs_srr

ipv4

<OM VIP IPv4 Address>

mtas_om

ProvisioningLDAP_secure

tcp

17423

PLs_srr

ipv4

<OM VIP IPv4 Address>

mtas_om

RoRf_1

tcp

3868

PLs_rr

ipv4

<OM VIP IPv4 Address>

mtas_om

RoRf_2

tcp

3869

PLs_rr

ipv4

<OM VIP IPv4 Address>

mtas_om

RoRf_3

tcp

3870

PLs_rr

ipv4

<OM VIP IPv4 Address>

mtas_om

RoRf_4

tcp

3871

PLs_rr

ipv4

<OM VIP IPv4 Address>

mtas_om

RoRf_5

tcp

3872

PLs_rr

ipv4

<OM VIP IPv4 Address>

mtas_om

CAI3G

tcp

8095

PLs_srr

ipv4

<CAI3G VIP IPv4 Address>

mtas_om

CAI3G-HTTPS

tcp

8443

PLs_srr

ipv4

<CAI3G VIP IPv4 Address>

mtas_sig

XCAP

tcp

8090

PLs_rr

ipv4

<Ut VIP IPv4 Address>

mtas_sig

ShDh_1

tcp

3868

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

ShDh_2

tcp

3869

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

ShDh_3

tcp

3870

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

ShDh_4

tcp

3871

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_01t

tcp

5060

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_01u

udp

5060

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_02t

tcp

5082

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_02u

udp

5082

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_03t

tcp

5083

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_03u

udp

5083

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_04t

tcp

5084

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_04u

udp

5084

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_05t

tcp

5085

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_05u

udp

5085

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_06t

tcp

5086

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_06u

udp

5086

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_07t

tcp

5087

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_07u

udp

5087

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_08t

tcp

5088

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_08u

udp

5088

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_09t

tcp

5089

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_09u

udp

5089

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_10t

tcp

5090

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_10u

udp

5090

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_11t

tcp

5160

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_11u

udp

5160

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_12t

tcp

5161

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_12u

udp

5161

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_13t

tcp

5162

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_13u

udp

5162

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_14t

tcp

5163

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SIP_14u

udp

5163

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

soap_http

tcp

9080

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

CCMP

tcp

8096

PLs_rr

ipv4

<Traffic VIP IPv4 Address>

mtas_om

6ProvisioningLDAP

tcp

17323

PLs_srr

ipv4

<OM VIP IPv6 Address>

mtas_om

6ProvisioningLDAP_secure

tcp

17423

PLs_srr

ipv4

<OM VIP IPv6 Address>

mtas_om

6RoRf_1

tcp

3868

PLs_rr

ipv4

<OM VIP IPv6 Address>

mtas_om

6RoRf_2

tcp

3869

PLs_rr

ipv4

<OM VIP IPv6 Address>

mtas_om

6RoRf_3

tcp

3870

PLs_rr

ipv4

<OM VIP IPv6 Address>

mtas_om

6RoRf_4

tcp

3871

PLs_rr

ipv4

<OM VIP IPv6 Address>

mtas_om

6RoRf_5

tcp

3872

PLs_rr

ipv4

<OM VIP IPv6 Address>

mtas_om

6CAI3G

tcp

8095

PLs_srr

ipv4

<CAI3G VIP IPv6 Address>

mtas_om

6CAI3G-HTTPS

tcp

8443

PLs_srr

ipv4

<CAI3G VIP IPv6 Address>

mtas_sig

6XCAP

tcp

8090

PLs_rr

ipv4

<Ut VIP IPv6 Address>

mtas_sig

6ShDh_1

tcp

3868

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6ShDh_2

tcp

3869

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6ShDh_3

tcp

3870

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6ShDh_4

tcp

3871

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_01t

tcp

5060

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_01u

udp

5060

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_02t

tcp

5082

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_02u

udp

5082

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_03t

tcp

5083

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_03u

udp

5083

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_04t

tcp

5084

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_04u

udp

5084

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_05t

tcp

5085

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_05u

udp

5085

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_06t

tcp

5086

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_06u

udp

5086

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_07t

tcp

5087

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_07u

udp

5087

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_08t

tcp

5088

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_08u

udp

5088

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_09t

tcp

5089

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_09u

udp

5089

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_10t

tcp

5090

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_10u

udp

5090

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_11t

tcp

5160

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_11u

udp

5160

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_12t

tcp

5161

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_12u

udp

5161

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_13t

tcp

5162

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_13u

udp

5162

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_14t

tcp

5163

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6SIP_14u

udp

5163

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6soap_http

tcp

9080

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

mtas_sig

6CCMP

tcp

8096

PLs_rr

ipv4

<Traffic VIP IPv6 Address>

Note:  
Opening ports of unused services must be avoided.

3.5.5.2   Flow Policies for SCTP

Flow policies for incoming SCTP streams can be created by using the following template:

ManagedElement=1,Transport=1,Evip=1,EvipAlbs=1,EvipAlb=<ALB name>,EvipFlowPolicies=1,EvipFlowPolicy=<FlowPolicy ID>
dest=<VIP address>
addressFamily=<Address family>
protocol=sctp
soGrp=1011250
top
commit -s

Create all the required flow policies in-line with Table 4. Refer to MTAS Hardening Guide for further details regarding MTAS supported SCTP SAPs.

Table 4    Summary of MTAS flow policies for incoming SCTP streams

ALB Name

FlowPolicy ID

Address Family

VIP Address

mtas_sig

SCTP_H248

ipv4

<Traffic VIP IPv4 Address>

mtas_sig

SCTP_SIGTRAN_1

ipv4

<SIGTRAN1 VIP IPv4 Address>

mtas_sig

SCTP_SIGTRAN_2

ipv4

<SIGTRAN2 VIP IPv4 Address>

mtas_sig

SCTP_H248

ipv6

<Traffic VIP IPv6 Address>

mtas_sig

SCTP_SIGTRAN_1

ipv6

<SIGTRAN1 VIP IPv6 Address>

mtas_sig

SCTP_SIGTRAN_2

ipv6

<SIGTRAN2 VIP IPv6 Address>

Note:  
  • Opening ports of unused services must be avoided.
  • SCTP transport is supported in one container, in the mtas_sig ALB only. This can be improved in a later MTAS release.



Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    MTAS Internal and External Connectivity         MTAS