| Attributes |
string key mandatory noNotification restricted |
-
pmThresholdMonitoringId
-
Value component of the RDN.
|
int64 mandatory |
-
thresholdHigh
-
Defines the high-threshold level for this alarm severity.
For each pair of high-threshold and low-threshold levels, one of them must generate an alarm notification - or increase the severity of an existing alarm. The other one must generate an alarm clear notification, or decrease the severity of an existing alarm.
If the direction of the threshold is increasing, a new alarm (or severity increase of an existing alarm) is not generated before the measurement value has (a) crossed or (b) reached the high-level threshold value.
Furthermore, an existing alarm is not cleared (or its severity decreased) before the measurement value has reached or crossed the low-level threshold value.
For decreasing thresholds, the opposite is applied. The hysteresis mechanism can be used for both Gauges and Cumulative Counters thresholds.
|
int64 mandatory |
-
thresholdLow
-
Defines the low-threshold level for this alarm severity.
For each pair of high-threshold and low-threshold levels, one of them must generate an alarm notification, or increase the severity of an existing alarm. The other one must generate an alarm clear notification, or decrease the severity of an existing alarm.
If the direction of the threshold is increasing, a new alarm (or severity increase of an existing alarm) is not generated before the measurement value has (a) crossed or (b) reached the high-level threshold value.
Furthermore, an existing alarm is not cleared (or its severity decreased) before the measurement value has reached or crossed the low-level threshold value.
For decreasing thresholds, the opposite is applied. The hysteresis mechanism can be used for both Gauges and Cumulative Counters thresholds.
|
SeverityLevel[0..1] |
-
thresholdSeverity
=
MINOR
-
Threshold severity.
One of the following Severity Levels must be assigned per threshold, in order to raise a threshold alarm of this severity, or change an existing alarm to this severity, if that threshold is reached or crossed:
CRITICAL
MAJOR
MINOR
WARNING
Severity level CLEARED is not a valid severity level and cannot be assigned to this attribute.
|