1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is raised by the middleware Availability Management Framework (AMF) service.
The alarm is raised when the AMF cannot successfully clean up a software component in the Managed Element (ME). The AMF performs a cleanup operation to free the resources allocated by a software component in the ME. The AMF assumes that the software component can be in an erroneous state in which it cannot actively perform any cleanup operation itself.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The cleanup function of the software component is defect |
The software component the AMF tries to clean up does not acknowledge its successful cleanup in time |
The software component is defect |
The software component that fails to be cleaned up |
The service the software component provides is degraded or lost. The failing software component is permanently taken out of operation. The fault can also cause a service disruption because of redundancy model constraints prohibiting the AMF to failover the service to the standby software component. |
|
The High Availability (HA) configuration for the software component is incorrect |
The AMF configuration of the software component is incorrect, for example, it defines an incorrect clean-up command or too short time for cleaning up |
The AMF configuration for the software component is defect |
The configuration of the software component that fails to be cleaned up |
- Note:
- The alarm can appear as a result of a software upgrade.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
18568 |
|
Minor Type |
131075 |
|
Source |
safApp=<*>,safSg=<*>,safSu=<*>,safComp=<*> |
|
Specific Problem |
|
|
Event Type |
processingErrorAlarm (4) |
|
Probable Cause |
x736UnspecifiedReason (418) |
|
Additional Text |
Cleanup of Component <LDAP DN of component> failed |
|
Perceived Severity |
major (4) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following document:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- A COM SA, AMF Component Cleanup Failed alarm is raised.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
Do the following:
- Was the alarm raised during initial installation or upgrade?
Yes: Contact the deployment organization. Proceed with Step 5.
No: Continue with the next step.
- Perform a health check, refer to Health Check documentation available in the library.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.