| 1 | Overview |
| 1.1 | Description |
| 1.2 | Prerequisites |
2 | Procedure |
1 Overview
1.1 Description
The alarm is issued when the number of connections in use has exceeded the high watermark threshold.
|
Major type |
193 |
|
Minor type |
1586562353 |
|
MO Class |
N/A |
|
Specific Problem |
Connections Exceed High Threshold |
|
Severity |
SEVERITY_WARNING |
The threshold is given in the configuration file as a percentage of the maximum number of connection resources made available for the entire SCCP.
1.2 Prerequisites
1.2.1 Documents
Before starting this procedure, make sure that you have read the following documents:
- "Fault Management User Guide" (24/1553-APR 901 0315/2 Uen)
- "Configuring SS7, System Components" (7/1543-CNA 403 0874/1 Uen)
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
Perform the following steps:
- Check the log file for further details.
- Check the high watermark threshold value in the SCCP configuration and amend if required.

Contents