class MtasSipOc

ManagedElement
+-MtasFunction
+-MtasSip
+-MtasSipOc

Not used in this release. MOC provides possibility for setting attributes of defined SIP Upstream Overload Control.

Attributes
integerKeyString
key
mandatory
noNotification
restricted
mtasSipOc
Not used in this release. This attribute defines the primary key of MtasSipOc and this section describes the MtasSip Overload Control attributes.
MtasUint00000to000200DT
mtasSipOcAbatement = 75
Not used in this release. This attribute defines threshold which MTAS decrements the reported ‘oc’ value periodically while the resource utilization level is below it.

Takes effect: New session
BasicAdmState
mtasSipOcAdministrativeState = LOCKED
Not used in this release. This attribute defines lock or unlock the support of adding OC parameters in Via header of SIP response for SIP Upsteam Overload Control . Possible values are 0 (LOCKED) and 1 (UNLOCKED) Default value is 0 (LOCKED).

Takes effect: New session
MtasUint00000to000100DT
mtasSipOcDefDecrStep = 8
Not used in this release. This attribute defines the default step value by which the ‘oc’ will be decreased.

Takes effect: New session
MtasUint00000to000100DT
mtasSipOcDefIncrStep = 12
Not used in this release. This attribute defines the default step value by which the ‘oc’ will be increased.

Takes effect: New session
MtasUint00000to000200DT
mtasSipOcOnset = 85
Not used in this release. This attribute defines the threshold which MTAS increments the reported ‘oc’ value periodically while the resource utilization level is above it.

Takes effect: New session
MtasSipOcRegulationIntervalDT
mtasSipOcRegulationInterval = 1000
Not used in this release. This attribute defines the OC regulation period in ms.

Takes effect: New session
MtasSipOcResourceDT[0..64] nonUnique
mtasSipOcResource
Not used in this release. This attribute defines the resources and optionally their limits which are considered in overload situation. Format shall be <resource type>[&limit]. Limit is integer from 0-100. Examples: CPU, CPU&80.
The available resource types are described in the MTAS SIP Overload Control Management Guide.
PLEASE BE CAUTIOUS BY OVERRIDING THE DEFAULT VALUES! - it significantly impacts the behavior of the SIP Overload Control feature.


Takes effect: New session
MtasSipOcValidityDT
mtasSipOcValidity = 1500
Not used in this release. This attribute defines the OC validity in ms which set as oc-validity in Via header.

Takes effect: New session