1 Introduction
This document describes the MtasJc, ICBS Data Not Found Alarm.
1.1 Alarm Description
The Alarm MtasJc, ICBS Data Not Found indicates an unsuccessful lookup of ICBS data in the MTAS database. The location information for which lookup is failed is stated in the Additional Info of the alarm. The alarm indicates a location Information configuration missing in MtasCommonDataAccNetwTypeAccInfo
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
The following is a list of the alarm attributes:
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
A Lookup of ICBS Data failed in MTAS because of the missing configuration |
Unsuccessful lookup of the ICBS Data in MTAS |
Missing configuration in LDAP for the specific access type and access info |
Configuration |
Lookup is to be Reattempted with home location obtained from the subscriber’s transparent data |
The alarm attributes are described in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6619218 |
|
Managed Object Class |
MtasJc |
|
Managed Object Instance |
MtasFunction.applicationName=MtasFunction,MtasServices.mtasServices=0,MtasMmt.mtasMmt=0,MtasJc.mtasJc=0 |
|
Specific Problem |
MtasJc, ICBS Data Not Found |
|
Event Type |
PROCESSINGERRORALARM (4) |
|
Probable Cause |
configurationOrCustomisationError(159) |
|
Additional Text |
- |
|
Perceived Severity |
WARNING |
|
Additional Info |
<MCC><MNC><CellID> |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that the following documents have been read:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- No ongoing maintenance activities are affecting the network or network elements.
- The user has proper authority to handle configuration management of the network elements.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
Do the following:
- Check if an entry exists in MtasCommonDataAccNetwTypeAccInfo with the access information received in the Additional Info of the alarm
- Define the MO entry with the required key based on the additional information attribute of the event. The key is defined as <accessType>& <access-info> For more information on how to configure MtasCommonDataAccNetwTypeAccInfo refer to Parameter Description for Provisioning MTAS MOCs.
- Clear the alarm manually using the CLI.
#ntfsend --notificationClassId=193,101,82 --perceivedSeverity=0
- Note:
- The alarm generation can be turned off by setting the mtasJcFailureNotification to DISABLED.