MtasJc, ICBS Data Not Found
MTAS

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This document describes the MtasJc, ICBS Data Not Found Alarm.

1.1   Alarm Description

The Alarm MtasJc, ICBS Data Not Found indicates an unsuccessful lookup of ICBS data in the MTAS database. The location information for which lookup is failed is stated in the Additional Info of the alarm. The alarm indicates a location Information configuration missing in MtasCommonDataAccNetwTypeAccInfo

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

The following is a list of the alarm attributes:

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

A Lookup of ICBS Data failed in MTAS because of the missing configuration

Unsuccessful lookup of the ICBS Data in MTAS

Missing configuration in LDAP for the specific access type and access info

Configuration

Lookup is to be Reattempted with home location obtained from the subscriber’s transparent data

The alarm attributes are described in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

6619218

Managed Object Class

MtasJc

Managed Object Instance

MtasFunction.applicationName=MtasFunction,MtasServices.mtasServices=0,MtasMmt.mtasMmt=0,MtasJc.mtasJc=0

Specific Problem

MtasJc, ICBS Data Not Found

Event Type

PROCESSINGERRORALARM (4)

Probable Cause

configurationOrCustomisationError(159)

Additional Text

-

Perceived Severity

WARNING

Additional Info

<MCC><MNC><CellID>

1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that the following documents have been read:

1.2.2   Tools

No tools are required.

1.2.3   Conditions

Before starting this procedure, ensure that the following conditions are met:

2   Procedure

Do the following:

  1. Check if an entry exists in MtasCommonDataAccNetwTypeAccInfo with the access information received in the Additional Info of the alarm
  2. Define the MO entry with the required key based on the additional information attribute of the event. The key is defined as <accessType>& <access-info> For more information on how to configure MtasCommonDataAccNetwTypeAccInfo refer to Parameter Description for Provisioning MTAS MOCs.
  3. Clear the alarm manually using the CLI.

    #ntfsend --notificationClassId=193,101,82 --perceivedSeverity=0

Note:  
The alarm generation can be turned off by setting the mtasJcFailureNotification to DISABLED.



Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    MtasJc, ICBS Data Not Found         MTAS