SS7 CAF OAM Connection Lost
Diameter Signaling Controller

Contents

1Overview
1.1Alarm Description

2

Procedure

1   Overview

This document is the Operating Instructions (OPI) for the alarm SS7 CAF OAM Connection Lost.

1.1   Alarm Description

This is an alarm of severity MAJOR.

The alarm is issued when the SM NTF Agent loses its connection towards the stack (to the OAM process).

The possible alarm causes and fault locations are explained in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

  • The OAM process has crashed.

  • Internal cluster network problem.

Operation and Maintenance connection lost.

SM NTF Agent loses its connection towards the stack to the OAM process.

Network


Cluster

Any alarms or notifications sent by the stack during the time the connection is down will be lost.


The connection is automatically established once the OAM process is restarted or the internal cluster network is available again.


If this alarm is raised for more than 1 minute follow the procedure below.

The following alarm attributes apply to this alarm:

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

1586563328

Managed Object Class

N/A

Specific Problem

OAM Connection Lost

Perceived Severity

SEVERITY_MAJOR

2   Procedure

Perform the following steps if the alarm is persistent (raised for more than 1 min):

  1. Check other alarms from the cluster about the internal cluster network status.
  2. 2. Enable trace on OAM as follows.
    • Login to the controller node.
    • Start the Signalling Manager CLI:

      SC-1:~ # dsc-connect-signalling-mgr

      cli> connect;

      EXECUTED

    • Enable OAM trace:

      cli> OAMTON;

      OAM-Trace On Successful
      EXECUTED

    • Keep the trace activated for 5 minutes.
    • Disable SCTP trace:

      cli> OAMTOF;

      OAM-Trace Off Successful.
      EXECUTED

  3. Collect the ss7trace.log located in /opt/sign/log.

    Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.

  4. Contact next level of support and provide the files collected in Step 3 above.


Copyright

© Ericsson AB 2014. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
Ericsson is a trademark of Telefonaktiebolaget LM Ericsson.
All trademarks are properties of their respective owners.

    SS7 CAF OAM Connection Lost         Diameter Signaling Controller