1 Overview
This document is the Operating Instructions (OPI) for the alarm SS7 CAF Process Down.
1.1 Alarm Description
This is an alarm of severity MAJOR.
The alarm is issued when an attempt to start a process is failed.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
An attempt to start a process failed. |
|
Internal cluster network |
Normally this is a non-fatal alarm; the ECM will try to start the process again. If the alarm is raised more than 5 times within 5 minutes or is persistent for 5 minutes, follow the procedure below. |
The following alarm attributes apply to this alarm:
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586561537 |
|
Managed Object Class |
N/A |
|
Specific Problem |
Process Down |
|
Perceived Severity |
SEVERITY_MAJOR |
2 Procedure
Perform the following steps if the alarm is raised multiple times or persistent:
- Check other alarms from the cluster about the internal cluster network status.
- Collect the ecm.log and ss7trace.log located in /opt/sign/log.
Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.
- Contact next level of support and provide the files collected in Step 2 above.