| 1 | Introduction |
| 1.1 | Alarm Description |
| 1.2 | Prerequisites |
2 | Procedure |
| 2.1 | Analyzing Alarm |
| 2.2 | Actions for Link Disabled by Operation and Maintenance |
| 2.3 | Actions for Link Disabled by Peer |
1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is raised when the relevant Diameter connection is either administratively disabled by Operation and Maintenance (OAM) or disabled by a peer.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Link disabled by O&M |
The Diameter connection is disabled by OAM |
The link is administratively disabled or a new link is created (disabled by default) |
Own node |
No traffic flow through the disabled link |
|
Link disabled by peer |
The Diameter connection is disabled by the peer |
The link is disabled because a Disconnect Peer Request (DPR) was received |
Peer |
- Note:
- The alarm is cleared automatically if one of the following
alarms is raised:
- vDicos, Diameter Peer Node Disabled
Alarms for connections to the peer node are cleared and a new alarm is raised for the peer node.
- vDicos, Diameter Own Node Disabled
Alarms for connections (and peer nodes) related to the own node are cleared and a new alarm is raised for the own node.
- vDicos, Diameter Peer Node Disabled
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2250572778 |
|
Managed Object Class |
|
|
Managed Object Instance |
ManagedElement=<node_name>,<ManagedFunction>=<FunctionId>,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=<stackId>,DIA-CFG-PeerNodeContainer=<stackId>,DIA-CFG-NeighbourNode=<hostId>#<stackId>,DIA-CFG-Conn=<stackId>#<hostId>#<connId> |
|
Specific Problem |
vDicos, Diameter Link Disabled |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
m3100Unavailable (14) |
|
Additional Text |
Detailed Information: Link disabled by OAM, IRP Cause: 14 Detailed Information: Link disabled by peer, IRP Cause: 14 |
|
Perceived Severity |
warning (6) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- A vDicos, Diameter Link Disabled alarm is raised.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
This section describes the procedure to follow when this alarm is received.
2.1 Analyzing Alarm
Select action according to the alarm cause indicated in the additionalText attribute:
- If the link is disabled by OAM, proceed with Section 2.2 Actions for Link Disabled by Operation and Maintenance.
- If the link is disabled by the peer, proceed with Section 2.3 Actions for Link Disabled by Peer.
2.2 Actions for Link Disabled by Operation and Maintenance
Do the following:
- Contact the network or node administrator. Is the node
administratively disabled for maintenance reasons?
Yes: Proceed with Step 13.
No: Continue with the next step.
- Is the alarm raised for a connection acting as responder
(incoming connection)?
Yes: Proceed with Step 8.
No: Continue with the next step.
- Navigate to the DIA-CFG-Conn Managed
Object (MO), for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc,DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1
- Enable the outgoing connection:
(DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>configure
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>enabled=true
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>commit
- Verify the setting:
(DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>show enabled
The following is an example output:
enabled=true
- Check the link status:
(DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>show linkStatus
The following is an example output:
linkStatus=Up
- Is the connection established?
Yes: Proceed with Step 10.
No: Proceed with Step 11.
- Contact the peer node administrator to enable the connection from the peer node.
- Proceed with Step 13.
- Is the alarm cleared?
Yes: Proceed with Step 13.
No: Continue with the next step.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.
2.3 Actions for Link Disabled by Peer
Do the following:
- Is the alarm raised for a connection acting as responder
(incoming connection)?
Yes: Continue with the next step.
No: Proceed with Step 6.
- Wait for the peer node to re-establish the connection and reception of a Capabilities-Exchange-Request (CER).
- Is the alarm cleared?
Yes: Proceed with Step 15.
No: Continue with the next step.
- Contact the network or peer node administrator to investigate the peer node.
- Proceed with Step 15.
- Navigate to the DIA-CFG-Conn MO,
for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc,DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1
- Check attribute blockReason:
(DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>show blockReason
The following is an example output:
blockReason="Not blocked"
- Is attribute blockReason of
the corresponding connection DPR received, cause=DoNotWantToTalkToYou, or DPR received, cause=Busy?
Yes: Continue with the next step.
No: Proceed with Step 11.
- Disable and enable the connection:
(DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>configure
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>enabled=false
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>commit -s
- Note:
- The value of attribute blockReason is automatically changed to Not blocked.
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>enabled=true
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>commit
- Verify the setting:
(DIA-CFG-Conn=abc\23node12.ericsson.com\23conn1)>show enabled
enabled=true
- Wait for automatic reconnect and sending of CER.
- Is the alarm cleared?
Yes: Proceed with Step 15.
No: Continue with the next step.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.