1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is raised when a Diameter own node has been disabled, either administratively or by the system because of a fault.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Diameter own node disabled |
The Diameter own node has been disabled |
Diameter own node disabled |
Own node configuration |
No service provided by the own node |
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2250572779 |
|
Managed Object Class |
|
|
Managed Object Instance |
ManagedElement=<node_name>,<ManagedFunction>=<FunctionId>,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=<stackId>,DIA-CFG-OwnNodeConfig=<stackId> |
|
Specific Problem |
vDicos, Diameter Own Node Disabled |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
m3100Unavailable (14) |
|
Additional Text |
Detailed Information: Own Node disabled by OAM, IRP Cause: 14 |
|
Perceived Severity |
minor (5) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following document:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- A vDicos, Diameter Own Node Disabled alarm is raised.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
Do the following:
- Contact the network or node administrator. Is the node
administratively disabled for maintenance reasons?
Yes: Proceed with Step 10.
No: Continue with the next step.
- Navigate to the DIA-CFG-OwnNodeConfig managed object, for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-OwnNodeConfig=abc
- Check the Diameter Own Node status:
(DIA-CFG-OwnNodeConfig=abc)>show enabled
The following is an example output:
enabled=false
- Is the Diameter Own Node enabled?
Yes: Proceed with Step 7.
No: Continue with the next step.
- Enable the Diameter Own Node:
(DIA-CFG-OwnNodeConfig=abc)>configure
(config-DIA-CFG-OwnNodeConfig=abc)>enabled=true
(config-DIA-CFG-OwnNodeConfig=abc)>commit
- Verify the setting:
(DIA-CFG-OwnNodeConfig=abc)>show enabled
The following is an example output:
enabled=true
- Is the alarm cleared?
Yes: Proceed with Step 10.
No: Continue with the next step.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.