LemCDCLSv, Operation Execution Timeout

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

The alarm is raised when the Crash Dump and Console Log Collection Service (CDCLSv) fails to collect and pack diagnostic data within the defined time-out interval.

The possible alarm causes and fault locations are explained in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

CDCLSv automatic collection and packing failure

CDCLSv has failed in automatically collecting and packing logs and crash dump files within the defined time-out interval

The CDCLSv service is not able to collect and pack the amount of diagnostic data before time-out is reached

Managed Element (ME) configuration

The failure of diagnostic data collection has no direct service impact as such. The absence of collected diagnostic data, however, affects the problem resolution flow negatively, and indirectly contributes to longer service degradation or downtime

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

1051649

Source

<dn>(1)


Example: cdclsPk=vDicos,cdcls=CDCLSvSite

Specific Problem

LemCDCLSv, Operation Execution Timeout

Event Type

communicationsAlarm (2)

Probable Cause

x733ResponseTimeExcessive(344)

Additional Text

Cdclsv packing process <dn> did not exit within time, alarm raised, reason: <reason>

Perceived Severity

warning (6)

(1)  Where <dn> is the distinguished name of the packing process object


1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

No documents are required.

1.2.2   Tools

No tools are required.

1.2.3   Conditions

Before starting this procedure, ensure that the following condition is met:

2   Procedure

The CDCLSv service needs to be configured with a higher time-out interval so it can successfully collect and pack diagnostic data and automatically clear the alarm.

Do the following:

  1. At the top level of the ME, use command cdclsv-get-timeout <dn> to display the current time-out value, for example:

    >cdclsv-get-timeout cdclsPk=vDicos,cdcls=CDCLSvSite

    Note:  
    <dn> is the distinguished name of the packing process object reported in the alarm.

    The following is an example output:

    1000
  2. Use command cdclsv-set-timeout <dn> <timeout_in_seconds> to set the time-out to a higher value, for example:

    >cdclsv-set-timeout cdclsPk=vDicos,cdcls=CDCLSvSite 1500

    The following is an example output:

    Timeout is set to 1500 for cdclsPk=vDicos,cdcls=CDCLSvSite
  3. Wait until the next diagnostic data collection and packing is completed.
    Note:  
    The time to wait depends on the predefined packing process period, plus the previously set time-out value.

  4. Is the alarm cleared?

    Yes: Continue with the next step.

    No: Proceed with Step 2.

  5. Job is completed.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    LemCDCLSv, Operation Execution Timeout