| 1 | Overview |
| 1.1 | Description |
| 1.2 | Prerequisites |
2 | Procedure |
1 Overview
1.1 Description
The alarm is issued when the number of links in a route falls below the threshold value for Link low availability.
|
Major type |
193 |
|
Minor type |
1586562654 |
|
MO Class |
N/A |
|
Specific Problem |
Low Link Availability |
|
Severity |
SEVERITY_WARNING |
The possible causes are as follows:
- The number of links has fallen below the threshold value for Link low availability because a number of links have been inhibited or are out of service.
As a result of the fault, the route does not have the expected number of available links.
1.2 Prerequisites
1.2.1 Documents
Before starting this procedure, make sure that you have read the following documents:
- "Fault Management User Guide" (24/1553-APR 901 0315/2 Uen)
- "Configuring SS7, System Components" (7/1543-CNA 403 0874/1 Uen)
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
Perform the following steps:
- Get status for each link. In Signalling Manager (SM) expandSignaling System and select a link.
- Click Actions , select M3-Link State and click Send . Find the result in Action Results .
- If a link is Locally Inhibited , click Actions , select M3-Link Uninhibit and click Send .
- Verify that the link is in service. Click Actions , select M3-Link Status and click Send .
- Repeat Step 1 to Step 4 for all links and all Local SPCs .
- Get status for all links. Click Actions , select M3 and M3-Status of all Links , click Send . Find the result in Action Results .
- If links are Out of Service (S01) or Aligning (S03) , return them back into service. Click Actions , select Normal Link Activation and click Send . Perform this procedure for each link.
- If this alarm occurs frequently, amend links to handle additional capacity.
- If the number of links is successfully increased and the
backlog is cleared, the alarm is also cleared.
If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.

Contents